• Title/Summary/Keyword: Standard estimating

Search Result 614, Processing Time 0.04 seconds

A Scheme to Optimize Q-Algorithm for Fast Tag Identification (고속 태그 식별을 위한 Q-알고리즘 최적화 방안)

  • Lim, In-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2541-2546
    • /
    • 2009
  • In the anti-collision scheme proposed by EPCglobal Class-1 Gen-2 standard, the frame size for a query round is determined by Q-algorithm. In the Q-algorithm, the reader calculates a frame size without estimating the number of tags in it's identification range. It uses only the slot status. Therefore, the Q-algorithm has advantage that the reader's algorithm is simpler than other DFSA algorithms. However, the standard does not define an optimized parameter value for adjusting the frame size. In this paper, we propose the optimized parameter values for minimizing the identification time by various computer simulations.

Determination of Arsenic in Korean human liver and manganese, copper in Vitamin prepartions by neutron action analysis (중성자(中性子) 방사화(放射化) 분석법(分析法)에 의(依)한 한국인(韓國人) 간장중(肝臟中)의 비소(砒素) 및 Vitamin제제중(製劑中)의 금속(金屬)(CU, Mn)의 정량(定量))

  • Oh, Soo-Chang
    • Journal of Pharmaceutical Investigation
    • /
    • v.4 no.4
    • /
    • pp.17-25
    • /
    • 1974
  • 1. Neutron acivation analysis of arsenic contained in Korean human liver was studied in the view point of forensic chemistry, using 12 corpses. A sample of 1g was irradiated for 30 mins. in a neutron flux of $1.2{\times}10^{12}n/cm^2/sec$, followed by nitric-sulfuric acid digestion and then by Gutzeit separation. Radio activity was detected by it's scintillation counter. The arsenic content in the liver was found to be $0.01{\mu}g/g$ to $0.15{\mu}g/g$. 2. A rapid and convenient method for the radiochemical determination of minerals by neutron activation analysis was established. After neutron irradiation to the standard soln. of Cu and Mn in pneumatic tube (neutron flux : $1.2{\times}10^{12}n/cm^2/sec$), Cu and Mn were determined by estimating the ratio of the widths under energy peak area in ${\gamma}-ray-spectrogram$. When the standard soln. of Mn and Cu is irradiated for 15 mins. to 18 hrs., recovery test shows that the relative errors are 5.1% and 4.5% for copper and manganese, respectively.

  • PDF

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

A study on the use of FT-NIR spectophotometer for dried laver quality evaluation (마른김 품질 평가를 위한 FT-NIR 분광기 활용 연구)

  • Kyoung-In, Lee;Geun-Jik, Lee;Young-Seung, Yoon
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • The micro-Kjeldahl method, a common technique for analyzing crude proteins, is time-consuming and dangerous due to the employment of reagents such as sulfuric acid and sodium hydroxide. However, a Fourier transform near-infrared (FT-NIR) spectrophotometer analysis can be completed in under a minute after simple pre-processing if data has been gathered using sufficient reference material in advance. Furthermore, the use of safe reagents in this technique ensures the safety of the experimenter and the environment. In addition, a portable FT-NIR spectrophotometer enables real-time measurement at processing or distribution sites and has recently gained popularity. The standard errors of calibration and regression (r2) for the calibration result for estimating the crude protein content of dried laver were 0.9775 and 1.2526, respectively. The standard error of prediction was 1.1814, and the r2 was 0.9303 in the validation results, which was a good level. In the present study, a method for predicting the crude protein content of dried laver using an FT-NIR spectrophotometer in the range of 29%-40% crude protein content has been reported.

Development of an Activity-Based Conceptual Cost Estimating Model for P.S.CBox Girder Bridge (대표공종 기반의 P.S.C 박스 거더교 개략공사비 산정모델 개발 -상부공사 중심으로-)

  • Cho, Ji-Hoon;Kim, Sang-Bum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.197-201
    • /
    • 2008
  • Conceptual cost estimates for domestic highway projects have generally been conducted using governmental unit-price references. Inaccuracies in governmental unit-price data has repeatedly addressed in the Korean construction industry which often lead to poor decision making and cost management practices. Thus, needs for developing a better way of conceptual cost estimating has been widely recognized. This research is considered as the first step in developing such model using real-world cost data based on actual construction activities. The data analyzed in this paper includes 41 P.S.C (Prestressed Concrete) Box bridges which broke into 4 categories based on construction methods such as I.L.M(Incremental Launching Method), M.S.S(Movable Scaffolding System), F.S.M(Full Staging Method), and F.C.M(Free Cantilever Method). Actual design documents; including actual cost estimating documents, drawings and specifications were carefully reviewed to effectively break down cost structures for PSC girder bridges. Among more than 40 cost categories for each P.S.C girder bridge type, 7 of them were identified which accounted for more than 95% of total construction cost (ILM: 99.47%, MSS: 99.22%, FSM: 98.18%, and FCM: 98.12%). In order to validate the clustering of cost categories, the variation of each cost category has been investigated which resulted in between -1.16 % and 0.59%.

  • PDF

Bootstrap estimation of the standard error of treatment effect with double propensity score adjustment (이중 성향점수 보정 방법을 이용한 처리효과 추정치의 표준오차 추정: 붓스트랩의 적용)

  • Lim, So Jung;Jung, Inkyung
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.3
    • /
    • pp.453-462
    • /
    • 2017
  • Double propensity score adjustment is an analytic solution to address bias due to incomplete matching. However, it is difficult to estimate the standard error of the estimated treatment effect when using double propensity score adjustment. In this study, we propose two bootstrap methods to estimate the standard error. The first is a simple bootstrap method that involves drawing bootstrap samples from the matched sample using the propensity score as well as estimating the standard error from the bootstrapped samples. The second is a complex bootstrap method that draws bootstrap samples first from the original sample and then applies the propensity score matching to each bootstrapped sample. We examined the performances of the two methods using simulations under various scenarios. The estimates of standard error using the complex bootstrap were closer to the empirical standard error than those using the simple bootstrap. The simple bootstrap methods tended to underestimate. In addition, the coverage rates of a 95% confidence interval using the complex bootstrap were closer to the advertised rate of 0.95. We applied the two methods to a real data example and found also that the estimate of the standard error using the simple bootstrap was smaller than that using the complex bootstrap.

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

A Study on the Method of Computing Standard Wartime Maintenance Man-Hour Incorporating Wartime Maintenance Condition (전장 정비환경을 고려한 전시 표준정비인시 산출방안 연구)

  • Kim, Min-Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.477-483
    • /
    • 2021
  • In a military maintenance system, the standard maintenance man-hour of weapon systems is a tool to estimate the maintenance capabilities of maintenance units, provide standards for determining the maintenance needs and workload, and provide basic data for establishing a maintenance plan. The standard maintenance man-hours of major weapon systems have already been derived and used, but the standard maintenance man-hour in a wartime maintenance environment has not been computed. Therefore, the standard wartime maintenance man-hours need to be derived and This study proposes a process and method of computing the maintenance man-hours. In addition, this work suggests the criteria of collecting and screening data that is necessary for estimating the standard maintenance man-hours and introduces a methodology for analyzing the characteristics of maintenance man-hour distribution in the process. The proposed process first designs a model that reflects the wartime maintenance environment, selects statistical techniques, collects maintenance data, analyzes the descriptive statistics, estimates the distribution, and finally presents representative values of maintenance man-hour. Based on the proposed method, the standard wartime maintenance man-hours of the four weapon systems were calculated, and the distribution of the maintenance man-hours was analyzed to follow a lognormal distribution, and the method presented reliable results.

A Study on Diversification of the Elderly Living Cost Estimate (노인가계 생계비 산정의 다양화를 위한 연구-반물량방식과 통계분석방식을 중심으로-)

  • Lee, Sun-Hyung;Kim, Keun-Hong
    • 한국노년학
    • /
    • v.27 no.2
    • /
    • pp.473-486
    • /
    • 2007
  • This study focused on the diversification of the elderly living cost estimate through statistical analysis method and Engel method(market basket method). The results of this study were as follows. First of all, due to Engel method, it has shown that the minimum living cost of aged couples was 566,478won on average of 2006, single aged men 306,210 won and single aged women 260,276 won. Secondly, according to the first way of statistical analysis, the minimum living cost of elderly couples was 860,043won, the standard was 1,018,669won and abundant 1,287,555won. The second way of that, the minimum(of elderly couples) was 694.916won, the standard 1,037,779won and abundant 1,556,551won. Those numbers included imputed rent. These results were changed to that the minimum is 435,416won, the standard 548,250won and the abundant 699,844won when imputed rent were excluded Moreover, it was also represented that the minimum of Engel method was between that of quasi-relative standard line and that of not imputed rent. Lastly, in the deprivation indicators method studied by Korea Institute for Health and Social Affair, it was concerned that an underestimation of elderly deprivation might have been got if some inappropriate data include. Given this study, it could not be judged that various estimating ways had been tried were consistency, but market-basket method was keenly needed. Market-basket method is being an absolute estimating way including only elderly data. Therefore, what is asking for first is - because other analysis can be limited by absolute estimating ways, particularly market-basket method - to be required systemic and all-arounded elderly living cost with more various ways.

Use of Near-Infrared Spectroscopy for Estimating Lignan Glucosides Contents in Intact Sesame Seeds

  • Kim, Kwan-Su;Park, Si-Hyung;Shim, Kang-Bo;Ryu, Su-Noh
    • Journal of Crop Science and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.185-192
    • /
    • 2007
  • Near-infrared spectroscopy(NIRS) was used to develop a rapid and efficient method to determine lignan glucosides in intact seeds of sesame(Sesamum indicum L.) germplasm accessions in Korea. A total of 93 samples(about 2 g of intact seeds) were scanned in the reflectance mode of a scanning monochromator, and the reference values for lignan glucosides contents were measured by high performance liquid chromatography. Calibration equations for sesaminol triglucoside, sesaminol($1{\rightarrow}2$) diglucoside, sesamolinol diglucoside, sesaminol($1{\rightarrow}6$) diglucoside, and total amount of lignan glucosides were developed using modified partial least square regression with internal cross validation(n=63), which exhibited lower SECV(standard errors of cross-validation), higher $R^2$(coefficient of determination in calibration), and higher 1-VR(ratio of unexplained variance divided by variance) values. Prediction of an external validation set(n=30) showed a significant correlation between reference values and NIRS estimated values based on the SEP(standard error of prediction), $r^2$(coefficient of determination in prediction), and the ratio of standard deviation(SD) of reference data to SEP, as factors used to evaluate the accuracy of equations. The models for each glucoside content had relatively higher values of SD/SEP(C) and $r^2$(more than 2.0 and 0.80, respectively), thereby characterizing those equations as having good quantitative information, while those of sesaminol($1{\rightarrow}2$) diglucoside showing a minor quantity had the lowest SD/SEP(C) and $r^2$ values(1.7 and 0.74, respectively), indicating a poor correlation between reference values and NIRS estimated values. The results indicated that NIRS could be used to rapidly determine lignan glucosides content in sesame seeds in the breeding programs for high quality sesame varieties.

  • PDF