• Title/Summary/Keyword: Standard deviations

Search Result 1,081, Processing Time 0.023 seconds

Confabulation Following Injury of the Papez Circuit as a Result of Middle Cerebral Artery Infarction: A Diffusion Tensor Tractography Study (중대뇌동맥 허혈에 의한 파페츠 회로 손상과 작화증)

  • Yeo, Sang-Seok
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: In general, confabulation is defined as confusion of reality with past events without apparent prompting, in association with disruption of the capacity for retrieval and encoding of memory. We report on a patient who showed spontaneous confabulation associated with injury of the Papez circuit following middle cerebral artery (MCA) infarction. Methods: A 67-year-old female patient suffered cerebral infarct resulting from spontaneous MCA territory. After onset of the MCA infarct, she showed severe memory impairment and provoked confabulation. The Papez circuit was reconstructed for evaluation of part of it using diffusion tensor tractography (DTT). Fractional anisotropy (FA), mean diffusivity (MD), and tract volume were measured. Results: The right thalamocingulate tract showed a significant decrement of FA value and tract volume, and an increment of MD value by more than two standard deviations of that of normal control subjects. The tract volume in the left fornix and mammillothalamic tract decreased by more than two standard deviations of that of normal control subjects. Conclusion: Injuries of the Papez circuit were demonstrated in a patient who showed severe memory impairment and provoked confabulation following MCA infarct. We believe that analysis of the Papez circuit tract using DTT is useful in elucidating the cause of provoked confabulation in patients with MCA infarct.

Speech Noise Cancellation using Time Adaptive Threshold Value in Wavelet Transform

  • Lee Chul-Hee;Lee Ki-Hoon;Hwang Hyang-Ja;Moon In-Seob;Kim Chong-Kyo
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.244-248
    • /
    • 2004
  • This paper proposes a new noise cancellation method for speech recognition in noise environments. We determine the time adaptive threshold value using standard deviations of wavelet coefficients after wavelet transform by frames. The time adaptive threshold value is set up by using sum of standard deviations of wavelet coefficients in cA3 and weighted cD1. cA3 coefficients represent the voiced sound with lower frequency components and cD1 coefficients represent the unvoiced sound with higher frequency components. In experiments, we removed noise after adding white Gaussian noise and colored noise to original speech. The proposed method improved SNR and MSE more than wavelet transform and wavelet packet transform does. As a result of speech recognition experiment using noise speech DB, recognition performance is improved by $2\sim4\;\%.$

  • PDF

Highly Selective and Simple Zero and First Order Derivative Spectrophotometric Determination of Palladium by Using α-Benzilmonoxime in Triton X-100 Micellar Solution

  • Eskandari, Habibollah;Karkaragh, Gholamhassan Imanzadeh
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1731-1736
    • /
    • 2003
  • The reaction of ${\alpha}$-Benzilmonoxime with palladium(II) produces a green complex in triton X-100 micellar media. Palladium has been determined using zero and first derivative spectrophotometric methods. The absorbances of Pd(II)- ${\alpha}$--benzilmonoxime complex at 441.8 and 677.0 nm in 0.10 M perchloric acid solution were monitored and linear working ranges of 0.3-12.0 and 0.7-20 ${\mu}$g mL$^{-1}$ with detection limits of 0.07 and 0.10 ${\mu}$g $mL^-1$ were obtained, respectively. Also, recoveries in the range of 92.8 to 100.1% and relative standard deviations in the range of 0.4 to 7.1% were obtained. First derivative spectrophotometry has also been applied for palladium determination under the optimum condition. The linear dynamic range of 0.2-24.0 ${\mu}$g $mL^{-1}$ palladium with relative standard deviations of 0.6-6.9% and recoveries in the range of 94.9-102.5% has been obtained by first derivative spectrophotometry. The method shows high selectivity because of the high concentration of acid used, which prevents formation of complexes of ${\alpha}$--benzilmonoxime with the other cations. The palladium complex formed was stable at least one day. The method was successfully applied to the determination of palladium in some synthetic palladium alloys and palladium-charcoal powder.

COMPARATIVE STUDY OF THE MACROSCOPIC FINDING, CONVENTIONAL TOMOGRAPHIC IMAGING, AND COMPUTED TOMOGRAPHIC IMAGING IN LOCATING THE MANDIBULAR CANAL (하악관 위치 분석시 일반단층사진과 전산화단층사진의 비교연구)

  • Choi Hang-Moon;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.535-544
    • /
    • 1995
  • The purpose of this study was comparision of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and reformatted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2mm slice thickness and the sections were then radiographed(contact radiography). Each radiographic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. Following results were acquired : 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6mm difference between real values and radiographs. 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within. : filmm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibiity was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  • PDF

The Safety of Pood Treated with Gamma Radiation and Butylated Hydroxyanisole in the Feed of Flounder (Paralichthys olivaceus) and Mouse (넙치 및 마우스에서 방사선 조사 및 Butylated Hydroxyanisole을 첨가한 사료투여의 안전성)

  • 김세라;김성호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • We evaluated the wholesomeness of fish feeds treated with high-dose radiation. This study examined the safety of fish fed treated with high-dose irradiation (5 kGy) and butylated hydroxyanisole (BHA, 200 ppm). 100 flounder (Paralichthys olivaceus) were grouped into 4 and then the fishes fed the following feeds for 28 days: (1)standard feed; (2)standard feed, treated with BHA; (3)standard feed, irradiated to 5 kGy; (4)standard feed, treated with BHA and irradiated to 5 kGy. Four groups each 10 mice were fed the fish feeds same as (1)-(4) for 14 days. There were no observable differences between fishs fed the irradiated feed and those fed the standard feed with respect to growth, feed consumption, haematology and organ histopathology Parameters. There were no deviations in feed consumtion, haematology and organ histopathology parameters in the experiment of mice. We concluded that there were no irradiation-related effects.

Comparison of the Sulfur Dioxide Primary Standard Gases of NPL and KRISS

  • O, Sang Hyeop;Kim, Byeong Mun;Mun, Dong Min;Kim, Jin Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1341-1344
    • /
    • 2001
  • Comparison of sulfur dioxide primary standard gases of the Korea Research Institute of Standards and Science (KRISS, Korea) and the National Physical Laboratory (NPL, UK) was performed. 100 ${\times}$10-6 mol/mol and 1,000 ${\times}$10-6 mol /mol primary standard gases (designated NPL S115 and S114, respectively) prepared gravimetrically and validated in NPL were used as transfer standards. Transfer standards were analyzed by NDIR sulfur dioxide analyzer and compared with KRISS PSM 112-03-624 and PSM 112-03-625 prepared gravimetrically. Adsorption corrected relative deviations of the primary standard gases were agreed to within 0.1%, and this agreement is within the expanded uncertainties (k = 2) of the primary standards at the two laboratories.

Design and Implementation of a Distance Measurement System using Radar Sensor (레이더 센서를 이용한 거리 측정 시스템의 설계 및 구현)

  • Jang, Si-woong;Jung, Dong-hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1009-1014
    • /
    • 2018
  • In this paper, we have designed and implemented a system that utilizes a radar sensor to measure distance between a sensor and objects. The sensor module creates raw data and uploads the data on the distance measuring system, which detects the presence of objects by using standard deviation and average filters. The experiment found that an algorithm using average filters measured people with error rates of up to 9.7 meters and a maximum error rate of 0.02 meters or less. While in an algorithm using standard deviations, it was found that an object is measured at an error rate of up to a maximum distance of 9.7 meters and a maximum error rate of 0.15 meters. Therefore, we have concluded that if a distance was measured by using a radar sensor, algorithms using average filters resulted in a higher accuracy than standard deviations filters.

A Study on the Effect by Receiving Points as Measuring Floor Impact Sound (바닥충격음 측정 시 수음점 위치의 영향에 관한 연구)

  • Chung, J.Y.;Lee, S.H.;Jeong, G.C.;Oh, Y.K.;Joo, M.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.283-286
    • /
    • 2005
  • This study measures the levels of various receiving points for reducing deviations the floor impact sound. According to the results, 63-125Hz band appeals the large deviations. Among the spacial points, the spot of 0.75m from the wall correspond with the average of all spots. The KS stipulates that the receiving point should be off the wall more than 0.5m But obeying the rules, the large deviation appears. So, this study shows that the adequate receiving point is 0.75m from the wall.

  • PDF

Analysis and Evaluation of the Accuracy of Electromagnetic Power Measurement at National Calibration and Test Organizations (국가교정검사기관의 전자파전력 측정정확도의 분석 및 평가)

  • 강태원;강웅택;박병권
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.53-60
    • /
    • 1995
  • The aims of this study are to evaluate the measurement capability of the electromagnetic power and to understand the current state of standard maintanance of the eight participants among the thirteen national calibration and test organizations. The calibration factors were measured at six test frequencies, 50, 100, 500, 1000, 5000, 10000 MHz by organizations and KRISS on the basis of round robin test. The results were analyzed by calculating the standard deviation of the measured values from the standard values. The analysis shows good agreement within 1.0% for all participants at the measurement frequencies. Therefore, the measurement capability of all participants is good in the frequency range of 50 MHz to 10 GHz. For the four participants which specified standard deviations of repeated measurements in their reporst, the total uncertainties is less than 1.9% at the measurement frequencies.

  • PDF

Variation of Tracer Distribution During the Antarctic Polar Vortex Breakup Shown in ILAS and ILAS-II Data (ILAS와 ILAS-II 자료에서 나타난 남극 와동 붕괴기간의 미량기체 분포변화)

  • Choi, Wookap;Lim, Kyungsoo
    • Atmosphere
    • /
    • v.20 no.3
    • /
    • pp.367-377
    • /
    • 2010
  • Variation of tracer distribution during the vortex-breakup period in the Antarctic region was observed by the data from the Improved Limb Atmospheric Spectrometer (ILAS) and ILAS-II. All four trace species including methane, nitrous oxide, ozone, and water vapor show similar patterns of vertical gradient in spite of different structures of zonal mean mixing ratio. Timings of vortex breakup on each level are estimated by two different methods, and they are compared with zonal standard deviations following the latitude circle of each trace species. Although the tracers have different chemical life times and sink/source, the zonal standard deviation patterns show remarkable similarities. The zonal standard deviation shown here to measure the zonal asymmetry of tracer distribution is believed to diagnose the timing of the Antarctic polar-vortex breakup reasonably well.