• 제목/요약/키워드: Standard deviation of subtraction image

검색결과 7건 처리시간 0.022초

디지털공제프로그램간의 디지털공제영상 비교 (A comparison of subtracted images from dental subtraction programs)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구 (A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images)

  • 허영준;전인성;허민석;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제32권2호
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가 (DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS)

  • 조봉혜;나경수
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF

국소적 상관계수를 이용한 자동적 디지털 방사선 영상정합 (Automatic Registration of Images for Digital Subtraction Radiography Using Local Correlation)

  • 이원진;허민석;이삼선;최순철;이재성
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.111-117
    • /
    • 2004
  • 현재 치과 방사선 영상에 적용되고 있는 대부분의 영상공제술은 기준점을 이용한 정한에 근거하고 있다. 본 연구에서는 수작업에 의한 기준점 설정 방법을 이용하지 않고 자동적으로 정참을 수행하는 방법을 개발하였다. 두 영상의 기하학적 매칭을 국소적 관심영역(ROI)에 한정시켜서 이 관심영역 간의 상관계수를 비교한다. 두 영역의 상관계수가 최대화되는 affine 또는 perspective 변환 파라미터를 고속의 탐색전략을 이용하여 반복적으로 찾는다. 우선 1/4 스케일 영상에 대하여 근사적인 파라미터를 탐색한 후 다시 원래 영상에 대하여 미세한 매칭이 이루어진다. 개발된 방법은 Gaussian 잡음에 의해 손상된 모의영상을 모의변환을 하지 않은 영상과 동일한 정도의 정확도를 가지고 정합 할 수 있다. 개발된 방법의 perspective 변환을 이용한 정합의 정확도는 수작업에 의한 것보다 17%향상된 결과를 보였다. 결론적으로, 이 방법의 치과 임플란트 영상에의 적용은 거의 실시간으로 자동적이고 잡음에 강인한 정합을 제공한다.

AWGN 환경에서 가우시안 분포와 표준편차를 이용한 잡음 제거 (Noise Removal using Gaussian Distribution and Standard Deviation in AWGN Environment)

  • 천봉원;김남호
    • 한국정보통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.675-681
    • /
    • 2019
  • 잡음 제거는 영상 처리의 선행 과정에서 필수적으로 이루어지며, 잡음의 종류와 영상의 환경에 따라 다양한 기법들이 연구되고 있다. 그러나 기존 AWGN(additive white gaussian noise) 제거 기법들은 고주파 성분이 많은 영상에 대해 블러링 현상을 일으키며 다소 부족한 성능을 보인다. 따라서 본 논문에서는 영상의 AWGN 제거 과정에서 블러링 현상을 최소화하기 위한 알고리즘을 제안하였다. 제안한 알고리즘은 마스크 내부 화소 특성에 따라 고주파 성분필터와 저주파 성분 필터를 설정하며, 기준치에 입력 영상을 가감하여 각 필터의 출력을 계산한다. 최종 출력은 두 필터의 출력에 표준편차와 가우시안 분포를 통해 계산된 가중치를 적용한 것을 합산하여 구한다. 제안한 알고리즘은 기존 방법에 비해 AWGN 제거 성능이 우수하였으며, 시뮬레이션을 통해 이를 확인하였다.

뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식 (Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.961-968
    • /
    • 2019
  • 본 연구는 CT를 이용한 뇌혈관 추출 검사에서 이중에너지 기법을 활용하여 각 에너지 준위별 뇌혈관 조영술의 유용성을 평가하였다. 방법은 CT 뇌혈관 조영술을 시행한 환자 15명의 DE 영상과 SE 영상을 대상으로 하였다. 영상의 분석은 MCA, 뇌실직 조직, Background에 ROI를 설정하여 평균값, 표준편차 및 SNR, CNR 값을 구하고, SE영상과 비슷하게 구현되는 에너지 영역을 알아보았다. Likert 5점 척도 육안평가를 병행한 결과 DE 40 keV와 SE 120 kVp에서 가장 선명한 MCA 영상을 확인 하였다(p>0.05). SE영상의 SNR 값은 DE영상의 40 keV에너지 준위값과 비슷하게 측정되었고, 40 keV와 50 keV의 저에너지 준위의 영상이 SNR이 높게 측정되어 고에너지 준위의 영상에 비해 대조도가 높아 뇌혈관질환을 유용하게 관찰할 수 있을 것으로 사료된다.

VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현 (Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.34-42
    • /
    • 2003
  • World Wide Web (WWW)에서 Virtual Reality Modeling Language (VRML)를 이용하는 3차원 (3D) 디스플레이는 사용자에게 직관적인 정보를 더 효과적으로 제공해 준다. 웹을 기반으로 하는 해부학적 영상과 융합되는 기능적 영상의 3D 가시화는 아직까지 체계적인 방식으로 연구가 활발히 진행되지 않았다. 이 연구의 목적은 2D 영상들과 함께 웹에서 VRML을 이용하여 구현되는 3D 해부학적 표면 영상들과 기능적 표면 영상들을 동시적으로 관찰할 수 있게 하고 VRML을 통해 만들어진 거리 측정 도구를 가지고 관심영역의 공간적인 위치 정보를 제공하는 것이다. 본 연구에서는 한 명의 간질 환자로부터 Magnetic Resonance (MR) 축면 영상과 발작기 및 발작간기 Single Photon Emission Computed Tomography (SPECT) 축면 영상들을 각각 획득하였다. 발작 진원지의 확인을 향상시키기 위해서 subtractionictal SPECT coregistered to MRI (SISCOM)을 수행하였다 SISCOM 결과로 나타난 각 2D 영상들은 모든 voxel들의 평균값 위로 1-표준편차와 2-표준편차에 해당하는 문턱 이상의 영상 값을 갖도록 하였다. SISCOM으로 나타나는 간질 발작 진원지들과 MRI 영상에서 회색질, 백색질 및 뇌척수액의 경계들을 각각 분할하고 marching cube 알고리즘에 의해 VRML 표면 영상들로 나타내었다. 축면 영상에서 실제 거리를 나타내는 x, y축의 길이를 획득하고 z축선의 길이를 계산하였다. VRML을 이용한 거리 측정도구를 만들어 이전의 VRML 표면 영상들과 융합하였다. MRI 영상을 이용하여 3D 표면 영상들의 단면을 나타내고 3D 표면 영상들의 투명도를 설정하기 위해 Java Script 루틴을 사용자 인터페이스 도구로서 삽입하였다 웹 페이지에서 구현되는 3D 표면 영상들의 투명도와 관찰 위치를 조절함에 따라 모델들 사이의 공간적인 정보를 직관적으로 알 수 있었다. 간질 발작 진원지에 대응하는 해부학적 구조를 3D 표면 영상들을 가로지르는 MRI 평면 영상들을 통해서 확인하였다 간질 발작 진원지는 뇌의 오른쪽 측두엽에서 나타났고 공간적으로 발작 진원지의 실제 위치를 VRML 거리 측정 도구에 의해 알 수 있었다. 결론적으로 본 연구에서 제시하는 웹에 근거한 3D 융합 영상의 가시화와 위치 측정은 진단 및 치료 방사선학과 외과학 등의 분야에서 온라인 방식의 연구와 교육에 있어 많은 도움을 줄 것이다.

  • PDF