• Title/Summary/Keyword: Standard bus

Search Result 217, Processing Time 0.027 seconds

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.

Breakdown Characteristics of Dry Air under 170[kV] GIB (170[kV] GIB 내에서 건조공기(Dry Air)의 절연파괴 특성)

  • Han, Ki-Son;Yoon, Jin-Yul;Ju, Hyung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.136-142
    • /
    • 2010
  • In this paper, we changed $SF_6$ insulation gases used already in the GIB(Gas Insulated Bus, gas insulated busbar) of switching appliances of power grid 170[kV] GIS(Gas Insulated Switchgear, Gas Insulated Switchgear) with green insulation dry air gases and studied dielectric breakdown voltage characteristics by the AC voltage withstand test. Withstand test AC voltage applied to the standard KEPCO's 170[kV] GIB with dry air insulation and and the equivalent of dry air and $SF_6$ gas were examined. Breakdown voltage of dry air, using an expression of the experiments were calculated and AC Withstand criterion of dry air insulation for the AC voltage test was derived. Using the criterion, dry air gases can be used instead of the $SF_6$ gas was confirmed in the factory acceptance test at 170[kV] GIB.

Study on IEC 61850 Performance Testing Procedures of BF Protection IED (차단키 실패 보호 IED의 IEC 61850 시스템 성능 시험 절차서에 관한 연구)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.59-66
    • /
    • 2008
  • Korea Electric Power Research Institute in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology" is performing system verification. Breaker Failure protection IED can operate protection activity by communicating with other IEDs such as T/L IED, owing to IEC 61850 international standard and digital substation automation system. Accordingly, IED testing process should be changed from the conventional way by electrical contact test on individual IED to system based testing method by network communication. This paper describes how to test BF IED based on substation automation system and testing procedures using UML, which is used to implement S/W design.

Multiobjective Optimal Reactive Power Flow Using Elitist Nondominated Sorting Genetic Algorithm: Comparison and Improvement

  • Li, Zhihuan;Li, Yinhong;Duan, Xianzhong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.70-78
    • /
    • 2010
  • Elitist nondominated sorting genetic algorithm (NSGA-II) is adopted and improved for multiobjective optimal reactive power flow (ORPF) problem. Multiobjective ORPF, formulated as a multiobjective mixed integer nonlinear optimization problem, minimizes real power loss and improves voltage profile of power grid by determining reactive power control variables. NSGA-II-based ORPF is tested on standard IEEE 30-bus test system and compared with four other state-of-the-art multiobjective evolutionary algorithms (MOEAs). Pareto front and outer solutions achieved by the five MOEAs are analyzed and compared. NSGA-II obtains the best control strategy for ORPF, but it suffers from the lower convergence speed at the early stage of the optimization. Several problem-specific local search strategies (LSSs) are incorporated into NSGA-II to promote algorithm's exploiting capability and then to speed up its convergence. This enhanced version of NSGA-II (ENSGA) is examined on IEEE 30 system. Experimental results show that the use of LSSs clearly improved the performance of NSGA-II. ENSGA shows the best search efficiency and is proved to be one of the efficient potential candidates in solving reactive power optimization in the real-time operation systems.

Problem Analysis of Real-time Transaction and FieldBus Communication in Industrial Networks (산업기기 네트워크에서의 실시간 처리와 필드버스 통신의 문제점 분석)

  • Moon Sang-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.921-923
    • /
    • 2006
  • With the success of wireless technologies in consumer electronics, standard wireless technologies are envisioned for the deployment in industrial environments as well. Industrial applications involving mobile subsystems or just the desire to save cabling make wireless technologies attractive. Nevertheless, these applications often have stringent requirements on reliability and timing. In wired environments, timing and reliability are well catered for by fieldbus systems. When wireless links are included, reliability and timing requirements are significantly more difficult to meet, due to the adverse properties of the radio channels. In this paper, we thus discuss some key issues coming up in wireless fieldbus and wireless industrial communication systems.

  • PDF

A New Formulation for Coordination of Directional Overcurrent Relays in Interconnected Networks for Better Miscoordination Suppression

  • Yazdaninejadi, Amin;Jannati, Jamil;Farsadi, Murtaza
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.169-175
    • /
    • 2017
  • A safe and reliable protection system in distribution networks, specifically, those hosting distribution generation units, needs a robust over-current protection scheme. To avoid unintentional DG disconnection during fault conditions, a protection system should operate quickly and selectively. Therefore, to achieve this aim, satisfying coordination constraints are important for any protection scheme in distribution networks; these pose a challenging task in interconnected and large-scale networks. In this paper, a new coordination strategy, based on the same non-standard time-current curve for all relays, in order to find optimal coordination of directional over-current relays, is proposed. The main aim is to reduce violations, especially miscoordination between pair relays. Besides this, the overall time of operation of relays during primary and backup operations should be minimized concurrently. This work is being tackled based on genetic algorithms and motivated by the heuristic algorithm. For the numerical analysis, to show the superiority of this coordination strategy, the IEEE 30-bus test system, with a mesh structure and supplemented with distributed generation, is put under extensive simulations, and the obtained results are discussed in depth.

A Study on ESS-based hybrid power generation system with easy expansion (증설이 용이한 ESS기반 하이브리드 발전시스템 연구)

  • Kim, Hee-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.68-73
    • /
    • 2019
  • This study is the central axis of the MG (Micro-Grid) configuration and it has the link through the modular hybrid power source and the DC bus, and it provides the function to detect and block the illegal connection by using the standard socket, And to achieve stabilization. Development of power conversion device, smart distribution panel, integrated control system and efficient demand management are required, and compatibility with MG whole system is urgent. This is a hybrid power generation system that is safe with a common power connection protocol and can be easily connected to anyone. This makes it easy to manage data and prepare for expansion of various manufacturers' systems.

Analysis of Transit Passenger Movements within Seoul-Gyeonggi-Incheon Area using Transportation Card (대중교통카드자료를 활용한 수도권 통행인구 이동진단)

  • Lee, Mee Young;Kim, Jong Hyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.5
    • /
    • pp.12-19
    • /
    • 2016
  • An average of 20 million individual transit unit activities per day on the Seoul-Gyeonggi-Incheon public transportation network are provided as transportation card analysis data by the metropolitan district (99.02% by 2014 standard, Humanlive, 2015.4). The metropolitan transportation card data can be employed in a comprehensive analysis of public transportation users' current transit patterns and by means of this, an effective use plan can be explored. In enhancing the existing information on the bus and rail integrated network of the metropolis with public transportation card data, the constraints in the existing methodology of metropolitan transit analysis, which functions on a zone unit origin and destination basis, can be overcome. Framework for metropolitan public transportation card data based integrated public transportation analysis, which consists of bus and rail integrated transport modes, is constructed, and through this, a single passenger's transit behavior transit volume can be approximated. This research proposes that in the use of metropolitan public transportation card data, integrated public transportation usage, as a part of individual passenger spatial movements, can be analyzed. Furthermore, metropolitan public transportation card usage data can provide insights into understanding not only movements of populations taking on transit activities, but also, characteristics of metropolitan local space.

Design and Implementation of Modbus Communications for Smart Factory PLC Data Collection (스마트팩토리 PLC 데이터 수집을 위한 Modbus 통신 설계 및 구현)

  • Han, Jin-Seok;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.77-87
    • /
    • 2021
  • Smart Factory refers to a factory that can be controlled by itself with an intelligent factory that improves productivity, quality and customer satisfaction by combining the entire process of manufacturing and production with digital automation solutions. The manufacturing industry around the world is rapidly changing, with Germany, Europe, and the United States at the center. In order to cope with such changes, the Korean government is also implementing a policy to spread the supply of smart factories for small and medium-sized companies, and related ministries and agencies such as the Ministry of Commerce, Industry and Energy, the Ministry of SMEs and Venture Business, the Korea Institute of Technology and Information Promotion, and local technoparks, as well as large companies such as Samsung, SK and LG are actively investing in smart manufacturing projects to support smart factories[1]. Factory Automation (FA) construction has many issues regarding the connection of heterogeneous equipment. The most difficult aspect of configuring various communications from various equipment is the reason. Although it may not be known if there are standards or products made up of the same company, it is not easy to build equipment that is old, up-to-date, and different use environments through a series of communications. To solve this problem, we would like to propose a method of communication using Modbus, one of FieldBus, which is one of the many industrial devices of PLC, a representative facility control system, and is used as a communication standard.

Feasibility Study of Developing Ship Engineering Control System based on DDS Middle-ware (DDS 미들웨어 기반의 선박 통합기관감시제어체계 개발 가능성 연구)

  • Seongwon Oh
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.653-658
    • /
    • 2023
  • In systems like the combat management system of a naval ship or smart city of civilians, where many sensors and actuators are connected, the middle-ware DDS (Data Distribution Service) is mainly used to transmit large amounts of data. It is scalable and can effectively respond to the increase in sensors or equipment connected to the system in the future. The engineering control system (ECS), which plays an important role similar to the combat management system of a naval ship, still uses Server-Client model with industrial protocols such as Modbus and CAN (Controller Area Network) bus, to transmit data, which is unfavorable in terms of scalability. However, as automation and unmanned systems advance, more sensors and actuators are expected to be added, necessitating substantial program modification. DDS can effectively address such situations. The purpose of this study is to confirm the development possibility of an integrated monitoring and control system of a ship by using OpenDDS, which follows the OMG (Object Management Group) standard among the middle-ware DDS used in the combat management system. To achieve this goal, field equipment simulators and an ECS server were configured to perform field equipment data input/output and simulation using DDS was performed. The ECS prototype successfully handled data transmission, confirming that DDS is capable of serving as the middle-ware for the ECS of a ship.