• Title/Summary/Keyword: Standard Lux

Search Result 39, Processing Time 0.023 seconds

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

Optical Design of LED module for Street Light Applications

  • Aung, Aye Thida;Yang, Jong-Kyung;Lee, Seung-Min;Lee, Jong-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.1-8
    • /
    • 2008
  • In this paper, the optical properties of the 54[W] LED module have confirmed by changing the angles of LED modules for street light applications. The angle of LED module changed from the $0[^{\circ}]$ to $60[^{\circ}]$ varying by $20[^{\circ}]$ as horizontal direction ${\ominus}_1$. Morever, the angle of LED module changed from the $0[^{\circ}]$ to $15[^{\circ}]$ varying by $5[^{\circ}]$ as vertical direction ${\ominus}_2$. As a result of simulation, the average illumination was about 17[lux] and the overall illuminance uniformity was 0.29 for a 10.39[m] long and 6[m] wide illuminance area at height of 6[m], which is acceptable for street lighting illumination in the Illuminating Engineering Society(IES) standard.

A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park - (해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.3
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

Dynamic range expansion of active pixel sensor with output voltage feedback (출력 전압 피드백을 통한 능동 화소 센서의 동작 범위 확장)

  • Seo, Min-Woong;Seo, Sang-Ho;Kong, Jae-Sung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.274-279
    • /
    • 2009
  • In this paper, a wide dynamic range active pixel sensor(APS) with output voltage feedback structure has been designed by a 2-poly 4-metal 0.35 $\mu$m standard CMOS technology. We presented a novel APS with output voltage feedback, which exhibits a wide dynamic range. The dynamic range increases at the cost of an additional diode and an additional MOSFET. The output voltage feedback structure enables the control of the output voltage level by itself, as incident light power varies. It is confirmed that the light level which the output voltage level of proposed APS is saturated is about 120,000 lux, which is higher than that of a conventional 3-transistor APS.

Electric Lighting Energy Saving Through the Use of A Fresnel Lens Based Fiber-optic Solar Lighting System: Simulation and Measurements (광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감: 시뮬레이션 및 실측 비교)

  • Jeong, Haejun;Kim, Wonsik;Kim, Yeongmin;Han, Hyun Joo;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

A Standard Rose Cultivar 'Love Letter' with Thornless Stems and Red Colored Petals for Cut Flowers (무가시성 적색 절화장미 '러브레터' 육성)

  • Lee, Young Soon;Jung, Yun Kyung;Park, Mi Ok;Lim, Jae Wook
    • Horticultural Science & Technology
    • /
    • v.32 no.2
    • /
    • pp.269-275
    • /
    • 2014
  • A standard rose cultivar, 'Love Letter' was selected for cut flower from the progenies of a cross between 'Red Giant' and 'Ensemble' by the rose breeding team of the Gyeonggi-do Agricultural Research & Extension Services (GARES) in 2011. A standard rose cultivar 'Red Giant' with red colored (RHS Red Group 45C) petals and 1.8 prickles per stems of 10 cm was used as a mother plant. A standard rose cultivar 'Ensemble' with white and red purple colored (RHS White Group 155C + RHS Red Group N57B) petals and 2.4 prickles per stems of 10 cm was used as a pollen parent. 'Love Letter' was crossed in 2007 and seedlings were produced. After tests of specific characters from 2008 to 2011, this cultivar was finally selected and named. As a standard type with large sized flower, it has red colored (RHS Red Group 46A) petals with 9.3 cm flower diameter and 32.4 petals per flower. Vase life of this cultivar could be as long as 12 days. It takes 43 days from pruning to blooming and cut flower productivity was 152 stems/$m^2$ in a year. The stems of cut flower have no thorn and the length is about with 70.5 cm. When this cultivar grew below $15^{\circ}C$ and 1,000 lux, the petals color became dark red in winter season. 'Love Letter' was registered as a new cultivar on Korea Seed & Variety Service (KSVS) with No. 4482 on May 8, 2013.

Measurement of Optical Purity for Commercially Avialable Naproxen Sold in 2013 (2013년 시판된 나프록센의 광학순도 측정)

  • Seo, Hae Chan;Song, Jung Suk;Ryoo, Sang Hyun;Lee, Sang Heon;Ryoo, Dong Hyun;Yu, Jeong Jae;Ryoo, Jae Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.2
    • /
    • pp.179-185
    • /
    • 2014
  • Commercial (S)-naproxen was racemized under strong basic condition. After checking the peak position of (R)- and (S)-naproxen by analysis the recemized naproxen, optical purity of 19 commercialized naproxens sold in 2013 in Korea were examined by chiral HPLC. The Chiralcel OD-H column, ChiralHyun-LE(S)-1 column and LUX-Cellulose-1 column were used as chiral stationary phases and the mixed eluent of hexane:isopropanol:acetic acid as 100:1:0.1 was used as a mobile phase with a flow rate of 1.0 mL/min. Each data was obtained from an average value of at least three different experiments for each sample and the relative standard deviation of them appeared very small. The average optical purity values obtained from three different chiral columns were very similar and the total average optical purity value (99.32%) of nineteen commercialized naproxens used in this study were larger than those of three years ago (98.17%).

Measurement of Optical Purity for Commercially Avialable Dexibuprofen and Ibuprofen Sold in 2013 (2013년도 시판된 Dexibuprofen과 Ibuprofen의 광학 순도 측정)

  • Ryoo, Sang Hyun;Lee, Sang Heon;Seo, Hae Chan;Song, Jung Suk;Ryoo, Dong Hyun;Yu, Jeong Jae;Kim, Hyun Young;Lee, Jae Hwan;Ryoo, Jae Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.277-282
    • /
    • 2014
  • The optical purity of 11 commercial dexibuprofens and 7 ibuprofens sold in Korea in 2013 were examined by chiral HPLC. The Chiralcel OD-H column and LUX-Cellulose-1 column were used as chiral stationary phases and the mixed eluent of hexane:isopropanol:acetic acid as 100:1:0.1 was used as a mobile phase with a flow rate of 1.0 mL/min. Each data was obtained from an average value of at least three different experiments for each sample and the average value of relative standard deviation of them appeared very small, 0.19%. Average optical purity value (97.5%) of eleven commercial dexibuprofens used in this study were smaller than those of 9 years ago (99.2%), but larger than four years ago (95.6%). Enantiomeric ratios of (R)- and (S)-isomers of seven ibuprofen samples used in this experiment were achieved at about 50:50 which was different with the result (44:56) from four years ago.

Embedment Properties of Reflective Beads for Thermoplastic Road Markings (열가소성 차선도장에서 반사유리알의 함침특성)

  • Hong, In Kwon;Lee, Chang Geun;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.199-204
    • /
    • 2015
  • Thermoplastic road markings are one of the most widely used road markings in the world. However, the durability of domestic road markings is relatively shorter than that of the global average of, approximately, three years. To overcome it, the conventional thermoplastic road markings were prepared by adding polyolefin and oxidized PE wax to conventional petroleum resin. In addition, the melting viscosity was designed below 500 cP at $220^{\circ}C$ as well as the optimum viscosity for spray painting, and embedding ratio of glass beads were controlled about 50~60% by spraying in an interval of 1 second. Also the glass bead adhesive ratio was improved by reducing the amount of $CaCO_3$ below 40 wt%. The retroreflectivity was tested under four different conditions to evaluate the abrasion resistance of thermoplastic road markings. The retroreflectivity coefficient satisfied the international standard ($150mcd{\cdot}m^{-2}{\cdot}lux^{-1}$) in this study, and TPRM-7 was determined as an optimal ratio.

Biportal Endoscopic Spinal Surgery for Lumbar Intervertebral Disc Herniation (두 개의 입구를 통한 내시경 척추 수술: 요추부 추간판 탈출증에의 적용)

  • Lee, Ho-Jin;Choi, Dae-Jung;Park, Eugene J.
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Herniation of the intervertebral disc is a medical disease manifesting as a bulging out of the nucleus pulposus or annulus fibrosis beyond the normal position. Most lumbar disc herniation cases have a favorable natural course. On the other hand, surgical intervention is reserved for patients with severe neurological symptoms or signs, progressive neurological symptoms, cauda equina syndrome, and those who are non-responsive to conservative treatment. Numerous surgical methods have been introduced, ranging from conventional open, microscope assisted, tubular retractor assisted, and endoscopic surgery. Among them, microscopic discectomy is currently the standard method. Biportal endoscopic spinal surgery (BESS) has several merits over other surgical techniques, including separate and free handling of endoscopy and surgical instruments, wide view of the surgical field with small skin incisions, absence of the procedure of removing fog from the endoscope, and lower infection rate by continuous saline irrigation. In addition, existing arthroscopic instruments for the extremities and conventional spinal instruments can be used for this technique and surgery for recurred disc herniation is applicable because delicate surgical procedures are performed under a brightness of 2,700 to 6,700 lux and a magnification of 28 to 35 times. Therefore, due to such advantages, BESS is a novel technique for the surgical treatment of lumbar disc herniation.