• 제목/요약/키워드: Standard Lux

검색결과 39건 처리시간 0.024초

주택의 조명과 거주자의 면경착용 실태조사연구 (A Study on the Illumination of Household and Research on the Actual Conditions of Wearing Spectacles in Dwellers)

  • 석호작;남철현
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.54-66
    • /
    • 1991
  • As a result of measuring illumination and making up a question at home visit directly by investigator who trained over twenty days period from October 4 to 24, 1990, in order to render help which illumination problem against house, society against eyes or framing of health instruction potgram by seizing natural lighting actual conditions of house and actual conditions of wearing spectacles and by investigating interrelationship, I can summarize as follows. 1) In property of investigation subject, woman 66.9%, In an age, the twenties was largest of 27.4%, the forties was 20.2%, the fifties was 18.6%, the thirties was 17.4%. In academic career, those of upper secondary school grauates was largest of 28.6%, those who possess university career was 25.9%, those who middle school career was 20.9%, decoding of Korean alphabet was 2%. 2) By a residence area, a big city was 43.3%, farming and fishing villages were 20.3%, the rest was a small town and the administrative office of town, township. In positon of house, the middle area was 43.6%, resident of suburb area was 38.0%. In form of house, a Korean-style house was 40.8%, a western-style house was 34.8%, an apartment house was 11.0%. In the a standard of living, the middle classes 77.2%, the lower classes were 15.3%. In residential house unit of area, from 21 to 30 unit of area was largest of 31.5%, from 10 to 20 unit of area was 19.9%, from 31 to 40 was 18.7%. 3) The wearing spectacles rate of study user was 44.1%. By the area, those who wearing spectacles was more than a half of 50.8% in the resident of big city area. As passing from the farm area to the city, that is being resident of big city was high wearing spectacles rate. In position of house, as being residence in central street showed high wearing spectacles rate. (central street was 51.5%, the middle area was 44.5% and the suburb area was 40.1%.) It seemed similarity difference a variable by position of house from wearing spectacles in standard of 1%. By form of house, wearing spectacles rate those who resident in apartment house was 49.5%, that rate those who resident in a western-style house was high of 49.0%, that rate those who resident in a Korean-style house was the lowest 39.0%. By social position of resident in room, in students case who study showed very high, as university students were very high of 62.3% idn wearing spectacles rate, middle and high school students 'were 50.0%, members of society were 47.6%, workers 20.3%. It seemed similarity difference from academic career in standard of 1%. By an age, the thirties was high of 54.1% in wearing spectacles rate, the twenties was 43.2%, the teenage was the lowest of 11.8%. 4) In illumination of study, over 200Lux was high of 40.1%. but below 99Lux which inappropriate illumination to see the books was 32.4%. Average by area, below 99Lux was 22.7% and over 400Lux was 50.0% in case of wooden floor. As examine by area, below 99Lux was high of 27.0% a case of wooden floor in the big city area, it was not good in illumination passing from the farm area(15.0%) to the city(19.0%). Average illlumination by area of the main living room below 99Lux was high of 37.5%, less than 200Lux was 58.5% of whole. In general, illumination of the main livingroom was inappropriate. By area, the big city was 32.5% below 99Lux, the middle and small city area were 33.8%, town and township area were 45.0%, farming and fishing area were 42.8%. By area, in the big city, illumination of study was 52.5% over 200Lux and 28.9% below 99Lux. In case of the middle and small city, study user of below 99Lux was 38.8% and over 200Lux was 46.9%. In case of the seat of town township, below 99Lux was 34.1% and over 200Lux was 39.7%. In case of farming and fishing area, illumination of study was 33.4% below 99Lux and 48.4% over 200Lux. It tends to high rate of inappropriate illumination. 5) By position of house, in case of wooden floor, less than 100Lux was 24.5% in central street. It was bad illumination than others position of house. In case of the main livingroom, less than 100Lux was 40.4% in the suburb area. It was bad iliumnation than others position of house. In case of study, less than 100Lux was 35.4% in the middle area, it was worse in illumination. In case of the main living room, is seemed similarity difference in standard of 1%. 6) By form of house, in case of wooden floor, illumination of less than 100Lux was 23.8% in a western-style house, it was bad illumination than others form of house. In case of the main livingroom, illumination of less than 100Lux was 47.4% in a Korean-style house, it was remarkably bad illumination than others form of house. In case of study, a Korean-style house was 38.8%, it was very bad illumination than others form of house. In case of the main livingroom and study, it seemed similatrity difference each as P < 0.01 and P < 0.05 in standard of 1%. 7) The wearing spectacles rate of those who use room of illumination over 400Lux was 40.7%, and that of those who use room of illumination less than 100Lux was 28.1%. It seemed similarity differecce in standard of 1%. 8) In period of wearing spectacles, 21.3% of total investigator-highest-was from before five years, 8.6% was from before three years. Among those who use of illumintion less than 99Lux, 34.0% began to wear spectacles from before two years 31.7% was from before five years, 30.3% was from before four years. It seemed similarity difference from period of wearing spectacles by illumination in standard of 1 %. 9) Among cause which sight grow worse, the first was that it was each 33.2% and 27.4% in response rate because watch TV nearly to wearing spectacles person and non-wearing person. The second was that a lot of seeing books was 25.3% in wearing spectacles person and response rate for dark illumination was 7.4% in nonwearing spectacles person. It seemed similarity difference in standard of 1%. (P < 0.01). 10) In experience which take medicine good for eyes, it was 50.1% in wearing spectacles person and 8.5% in non-wearing spectacles person. It seemed similarity difference in standard of 1%(P < 0.01). As we have seen above, inappropriate illumination can be a cause of wearing spectacles. Nevertheless, actually, is realities to indifferent against illumination of house. So it must learn knowledge about health obstacle of illumination through society instruction and school eduction against students as well as general residents. In case that natural lighting is inappropriate structural of house, we must be able to maintain appropriate illumination through artificial illumination. And so eyes which is core of human life have to be protected, related the authorities, related group, and all health medical personnel will organically cooperate with and make efforts.

  • PDF

도로표시 규정 및 글라스비드 동향과 자율주행차량 시대를 대비한 제언 (Trend in glass bead and regulation of road marking, and suggestions for preparing an autonomous vehicle age)

  • 강병국;강승구
    • 한국결정성장학회지
    • /
    • 제29권5호
    • /
    • pp.229-237
    • /
    • 2019
  • 야간이나 악천후에서도 높은 도로의 차선인식률을 유지하기 위해, 통상 재귀반사(retro-reflectivity) 특성이 뛰어난 고 굴절률의 글라스비드(glass bead)를 도로표시 페인트 위에 도포한다. 국가별로 일반 도로표시의 재귀반사 기준이 다르며, 국내는 백색광 기준으로 $240mcd/m^2{\cdot}lux$, 선진국들은 $250{\sim}300mcd/m^2{\cdot}lux$로 규정되어있다. 본 논문에서는 도로표시 관련 규정과 글라스비드에 대한 동향에 대하여 고찰하고, 향후 자율주행차량 상용화에 대비하여 규정 기준치 및 글라스비드물성 향상 필요성에 대하여 논의하였다.

Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정 (Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe)

  • 김지민;한아영;이하영;이소라;권대철
    • 한국자기학회지
    • /
    • 제26권5호
    • /
    • pp.168-172
    • /
    • 2016
  • MRI 검사실의 최적환경을 목적으로 검사실 및 모니터의 휘도와 조도를 측정하였다. 대학병원(n = 6)의 MRI(n = 10)에서 휘도와 조도를 Unfors Xi Light Probe(Unfors Instruments AB, Billdal, Sweden)를 이용하여 측정하였다. 휘도는 black level과 white level을 조도는 모니터의 측면의 중앙에서 3회 반복하여 평균과 표준편차를 구하여 t-test를 이용하여 유의성 검정의 통계적 처리를 하였다. 모니터 휘도는 black level에서 평균 $1.78cd/m^2$, 표준편차 $0.85cd/m^2$이었고, white level에서는 평균 $43.58cd/m^2$, 표준편차 $13.19cd/m^2$로 측정되었다. MRI 검사실 조도는 최저값 30.5 lux, 최대값 601.3 lux, 평균 177.86 lux로 측정되었고, 휘도와 조도는 통계학적으로 유의한 차이가 있다(p < .05). MRI 모니터 및 검사실 휘도와 조도의 권고 기준을 참고하여 최적인 환경을 조성하도록 한다.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

Visual Perception for TCO'03 Angular-Dependence Luminance Uniformity of TFT-LCDs

  • Hsu, Yu-Ju;Chen, Hsin-Ming;Cheng, Yung-Chiang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.671-674
    • /
    • 2006
  • Due to the stricter requests of the human perception of images, many industrial standards such as TCO'03 have been made to survey the Flat Panel Displays (FPD) nowadays. The angular-dependence luminance uniformity is an important item to evaluate the performance of FPD. In this article, we focus on the above test item base on TCO'03 standard in the case of vertical direction of ${\pm}15^{\circ}$. With controlling the driving voltage toward the liquid crystals of TN-type TFT-LCD, there exists a voltage-driving range which can achieve the value of the $L_{max}/L_{min}$ at ${\pm}15^{\circ}\;{\leq}1.7$ readily. Both experiment and simulation have been well analysis.

  • PDF

만가닥버섯 재배시 광 종류에 따른 생육 특성 및 수량 (Effect of the light qualities on the growth characteristics and yield in the cultivation of Lyophyllum ulmarium)

  • 박재성;최재선;노창우;윤태;이창수
    • 한국버섯학회지
    • /
    • 제8권4호
    • /
    • pp.137-141
    • /
    • 2010
  • 1. 광 종류별 조도는 백색광은 2,270Lux로 가장 밝았으며, 황색광 1,750Lux, 청색광 460Lux, 적색광 400Lux의 순이었다. 2. 자실체 특성을 조사한 결과, CBM-1757이 느티만가닥버섯에 비하여 갓의 크기와 대직경이 양호한 경향이었으며, 광 종류간에는 황색광에서 다른 광에 비하여 다소 좋은 경향이었다. 3. 생육기간은 CBM-1757이 느티만가닥버섯에 비하여 균 배양일수는 2일, 초발이소요일수는 1일, 생육일수는 1일정도 단축되어 생육기간이 8일 정도 빠른 경향이었다. 광종류간에는 황색광에서 생육기간이 70일 소요되어 다른 광에 비하여 2~4일 정도 단축되는 경향이었다. 4. 유효경수 및 개체중은 품종간에 차이가 나지 않는 경향이었고, 병당 수량은 느티만가닥버섯 94.8g에 비하여 CBM-1757은 95.6g으로 약간 많았다. 광 종류간에는 백색광의 96.0g에 비하여 청색광 및 적색광에서는 2~9%가 감소되었으나, 황색광에서는 103.4g으로 8% 정도 증수되는 경향이었다. 5. 버섯의 색도는 CBM-1757이 느티만가닥버섯에 비하여 명도, 적색도 및 황색도가 높았으며, 광 종류간에는 황색광에서 다른 광에 비하여 다소 높은 경향이었다.

  • PDF

제주도 근해 멸치 분기초망의 집어효과에 관한 연구 (Study on the Gathering Effects of Anchovy Scoop Net in the neighboring waters of the Cheju Island)

  • 손태준
    • 한국수산과학회지
    • /
    • 제21권3호
    • /
    • pp.184-192
    • /
    • 1988
  • 제주도 연안에서 분기초망어선의 집어등에 의해 집어된 멸치의 집어상태를 1987년5월~8월간에 매월 중순을 기준하여 223해구와 233해구에서 분기초망어선에 어군탐지기(SR-385형)를 설치하여 수면상 2m 높이에 선수 전방 1m에 수상집어등 1Kw, 백열등 1개를 교류전압 100V로 수면에 조사했을 때의 멸치군의 유영수심, 집어등의 수중조도, 어획량의 변동, 그에 따른 집어효과를 조사한 결과는 다음과 같다. 1. 분기초망에 의한 멸치의 어획량은 월령의 상순 (1-10일)과 하순 (20-30일)에 전 어획량(259 M/T)의 $90\%$가 어획되는 반면 중순 (11-20일)에는 전어획량의 $10\%$정도로 낮았다. 2. 수상집어등에 의한 멸치군의 집어수심은 2~5m였고, 이 때의 수중조도는 223해구에서 20~42 Lux, 233해구에서는 24~48 Lux이다. 3. 수면상 2m 높이인 멸치 분기초망어선의 선수에 수상집어등 1Kw 백열등 1개를 교류전압 100V로 집어한 결과 수중조도 1.9~7 Lux인 수심 10~15m에서 유영하던 멸치군이 수중조도 20~42 Lux인 수심 2~5m까지 부상하므로서 분기초망어선의 집어등에 의해 집어되는 멸치군의 수중조도는 집어하기 이전의 수중조도보다 7~12배 정도 더 강한 수중조도 범위에 집어되었다. 4. 현재 제주도 연안에서 조업하고 있는 멸치분기초망의 어획수심은 수심 2~3m 까지이고, 최종 어획단계에서 수상집어등을 교류전압 100V에서 80V로 강압하므로서 집어등을 2m 높이에서 4m 높이로 이동시키지 않더라도 같은 집어효과를 얻을 수 있다.

  • PDF

축광 노면표시의 야간 시인성 평가를 위한 기초 연구 (Night Visibility Evaluation of Phosphorescent Road Line Markings)

  • 이용문;김상태;정왕성;김흥래
    • 한국도로학회논문집
    • /
    • 제18권4호
    • /
    • pp.69-75
    • /
    • 2016
  • PURPOSES : In this study, we evaluated changes in the retroreflectivity and luminance of phosphorescent road line markings with changes in glass beads and line marking thickness. METHODS : The color of line markings affects their retroreflectivity. Using a chromaticity test, we conducted the analysis of whether phosphorescent road line markings adhered to the "KS M 6080" standard. Then, we measured the dry retroreflectivity and wet retroreflectivity for various glass bead refractive indices. We conducted wet retroreflectivity test using the EN 1436 standard as the basis. We also conducted luminance tests for different glass bead refractive indices and line marking thicknesses. RESULTS : 1. Phosphorescent road line markings specimens satisfied the "KS M 6080" standard. 2. In dry retroreflectivity test, phosphorescent road line markings sprayed with glass beads satisfied the national police agency standard ($240mcd/(m^2{\cdot}Lux)$). Wet retroreflectivity test results showed that except for one type of No.1 glass beads, phosphorescent road line markings specimens sprayed with glass beads of one type of No.3 and two types of No.1 satisfied the national police agency standard ($100mcd/(m^2{\cdot}Lux)$). 3. Phosphorescent road line markings had higher retroreflectivity than non-phosphorescent road line markings in the dry condition. 4. Phosphorescent road line markings sprayed with glass beads demonstrated improved luminance. Luminance increased with higher glass bead refractive index and with increased line marking thickness. However, when the thickness crossed a certain threshold, phosphorescence ceased to increase; this is a characteristic of the phosphorescence phenomenon. CONCLUSIONS : Visibility across short distances can be ensured when phosphorescent road line markings are sprayed with glass beads, because of the retroreflection phenomenon. It is also possible to ensure far visibility using phosphorescent road line markings.

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

노면표시 색상에 따른 최소재귀반사성능 연구 (Study on the Minimum Recursive Reflection Performance according to the Color of Road Surface)

  • 한음;강종호;김청호;박성호;윤일수
    • 한국ITS학회 논문지
    • /
    • 제19권6호
    • /
    • pp.37-48
    • /
    • 2020
  • 도로교통법 시행규칙과 단체표준에서 정하고 있는 8가지 색상에 대해 건조 시와 습윤 시의 최소재귀반사성능 기준 확보를 위한 현장실험을 실시하였으며, 백색 건조 시에는 260.8(mcd/㎡·lux), 습윤 시에는 154.6(mcd/㎡·lux)으로 결과가 산출되었다. 황색의 경우는 건조 시 백색의 반사성능 대비 황색, 가호1호에서는 67%, 가호2호에서는 63% 수준이다. 습윤 시는 각각 79%와 59% 수준으로 나타났다. 청색의 경우에는 백색대비 가호1호에서는 64% 수준이며, 가호2호에서는 72%이다. 습윤 시는 각각 63%와 72% 수준으로 나타났다. 습윤 시의 반사성능 변화 폭이 건조 시보다 높으며, 유리알이 없는 경우도 이전의 결과와 비슷하게 나타났다. 신규색상이 적색, 주황색, 분홍색, 연한 녹색, 녹색의 경우에도 백색 대비 50% 이상의 기준값을 가지는 것으로 분석되었으며 이를 토대로 도로교통법 시행규칙에 노면표시 색상에 따른 최소반사성능 기준 마련의 토대가 될 것으로 판단된다.