• Title/Summary/Keyword: Standard Equivalent System

Search Result 152, Processing Time 0.024 seconds

Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration (표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정)

  • 권휴상;서상준;서재갑;박준홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF

Development of Equivalent Systems for the KEPCO Enhanced Power System Simulator (한전 실시간 시뮬레이터를 위한 등가계통 구성 연구)

  • Jang, Gil-Soo;Yun, Yong-Beum;Kim, Yong-Hak
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1434-1440
    • /
    • 1999
  • For the real-time power system analysis, there exists a limitation to the scale of the system to be simulated, hence it is necessary for the real-time simulation to develop reduced equivalent systems which preserve the desired property of the original system. In this paper, a procedure for developing an equivalent system whose scale is reduced within the hardware capacity of a real-time simulator is proposed. Also, the proposed procedure is applied to a KEPCO's system. The comparison between the original system and equivalent systems illustrates the capabilities of the proposed procedure.

  • PDF

Evaluation Standard of Cost-Effectiveness Analysis for Renew of Architectural Equipment in Public Building (공공건물 건축설비 갱신 계획시 비용-효율분석 평가기준에 관한 연구)

  • Jung, Soon-Sung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.131-138
    • /
    • 2013
  • The purpose of this study is to suggest the evaluation standard of cost-effectiveness analysis for renew of architectural equipment in public building. Evaluation items of cost-effectiveness analysis for renew of architectural equipment in public building were used life cycle cost, energy consumption(ton of oil equivalent), green house gas emissions(ton of carbon dioxide) and maximum power demand. Life cycle cost is the process of making an economic assessment of an item, area, system, or facility by considering all significant costs of ownership over an economic life, expressed in terms of equivalent costs. The essence of life cycle costing is the analysis of equivalent costs of various alternative proposals. The social concern with green house gas and maximum power demand of architectural equipment field has been growing for the last several years.

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

A Study of Power Conversion System for Energy Harvester Using a Piezoelectric Materials (압전소자를 이용한 에너지 하베스터용 전력변환장치 연구)

  • An, Hyunsung;Kim, Young-Cheol;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1059-1065
    • /
    • 2017
  • In this paper, the energy harvester with a piezoelectric materials is modeled as the electric equivalent circuit, and performances of a standard DC method and a Parallel-SSHI method are verified through experiment under variable force and load conditions. Piezoelectric generator consists of mass, damper and spring constant, and it is modeled by electrical equivalent circuit with RLC components. Standard DC and Parallel-SSHI are used as power conversion methods, and standard DC consists of full-bridge rectifier and smoothing capacitor. Parallel-SSHI method is composed of L-C resonant circuit, zero-crossing detector and full-bridge rectifier. In case of simulation under $100k{\Omega}$ load condition, the harvested power is $500{\mu}W$ in Standard DC and $670{\mu}W$ in Parallel-SSHI, respectively. In experiment, the harvested power under $100k{\Omega}$ load condition is $420{\mu}W$ in standard DC and $602{\mu}W$ in Parallel-SSHI. Harvested power of Parallel-SSHI is improved by approximately 40% more than that of standard DC method.

Mathematical Modeling of VSB-Based Digital Television Systems

  • Kim, Hyoung-Nam;Lee, Yong-Tae;Kim, Seung-Won
    • ETRI Journal
    • /
    • v.25 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • We mathematically analyze the passband vestigial sideband (VSB) system for the Advanced Television Systems Committee (ATSC) digital television standard and present a baseband-equivalent VSB model. The obtained baseband VSB model is represented by convolution of the transmission signal (before modulation) and the baseband equivalent of the complex VSB channel. Due to the operation of the physical channel as an RF passband and the asymmetrical property of VSB modulation, it is necessary to use a complex model. However, the passband channel may be reduced to an equivalent baseband. We show how to apply standard channel model information such as delay, gain, and phase for multiple signal paths to compute both the channel frequency response with a given carrier frequency and the resulting demodulated impulse response. Simulation results illustrate that the baseband VSB model is equivalent to the passband VSB model.

  • PDF

A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges (공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구)

  • Kim, Dong Su;Yoon, Jong Ho;Shin, U Cheul;Kwak, Hee Yul
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.

Evaluating of Road Traffic Noise in Apartment Sites With Calculations of Equivalent Noise Levels (단지등가소음도 계산을 통한 공동주택 교통소음 평가방법에 관한 연구)

  • 김경호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1040-1044
    • /
    • 2001
  • This study is to propose an analyzing method of road traffic noise in apartment sites using computer simulation program. The evaluation method used in this study is to calculate "Site Equivalent Noise Level". It will be possible to set up effective sound proof system with calculation of "The Number of Houses Exceeding Standard Noise Level".

  • PDF

A Study on the Equivalent Dynamic Stiffness of Bearing-pedestal (베어링 대의 등가 동강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.452-456
    • /
    • 2006
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and span of turbine-generator increases, the turbine-generator system is composed of many components such as bearings, pedestal, turbine and hood and so on. Also, it is getting flexible and has many critical speeds. Especially, as the characteristics of bearing-pedestal are very complicated, they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytical and experimental method.

A Study on the Equivalent Dynamic Stiffness of Bearing-Pedestal (베어링-페데스탈의 등가 강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun;Lee, Dae-Seong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.263-266
    • /
    • 2005
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and the span of turbine-generator increases, the turbine-generator system has many components such as bearings, pedestal, turbine and baseplates etc. and it is getting flexible and has many critical speeds. Especially, the characteristics of bearing-pedestal are very complicated and then they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytic and experimental method.

  • PDF