• Title/Summary/Keyword: Standard Drawing of School Architecture

Search Result 6, Processing Time 0.019 seconds

A Study on the Standard Drawings of Seoul Elementary School Architecture in 1960~70s (1960~70년대 서울시 국민학교 건축 표준설계도에 관한 연구)

  • Lee, Jung-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1718-1725
    • /
    • 2008
  • Until 1980s, Korean elementary school architecture has been stereotyped by standard drawings. But there have been very few researches focused on this subject, especially regional one. As an attempt to improve these conditions, this study reviewed standard drawings of elementary school architecture by Education Board of Seoul in 1964 and 1975. Both standard drawings were reviewed through items such as components making a set of standard drawings, floor plan, elevation design and subsidiary facilities. They have rectangular unit classrooms, single-corridor block plan and plain exterior having no symbolic images, which are the characteristics of typical Korean school architecture until 1980s. On the other hand, they reveal the unknown characteristics such as double-corridor block plan, classrooms in basement, toilets of conventional type placed on every floor and changes in details of openings and exterior wall.

A Study on Space Planning of Accommodations for Experiential Activities by Remodeling Closed Schools (폐교를 활용한 체험활동 숙박시설의 공간계획 분석)

  • Byun, Kyeonghwa;Kang, Eun-Jung;Yoo, Changgeun
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • This study aims to analyze space planning of accommodations in seven closed schools involved in experiential activity programs on Jeju Island, a famous tourist destination in Korea. The results are as follows. First, 35 schools had been closed down in Jeju between 1982 and 2015. Among them, four closed schools were sold, three are currently used by the Jeju special self-government provincial office of education, and 25 are being leased by individuals, village organizations, and other entities. However, they have not been well-operated, and so strategies for the effective management or operation of these closed schools should be developed. Second, there are distinctive differences in space planning of accommodations based on the correlation between experiential activities and the types of participants. If the experiential activity participants are mainly individuals or small groups, the closed school is likely to plan double-bed accommodations and individual bathrooms rather than large group rooms. Third, in order to operate experiential activity programs, closed schools require four different spaces for experiential activities, lodging, dining, and sanitation. The largest space available in each school building is used for experiential activities, and original classrooms are still in use. According to the standard drawing of school architecture, standard classroom size since 1997 has been $7.5{\times}9$ meters, and lodging rooms have mainly been re-planned based on the module of the standard-sized classroom. School cafeterias are utilized as dinning and kitchen spaces. For sanitation purposes, original school restrooms are still used by experiential program participants, while the shower rooms are newly equipped.

A Study on the Standard Drawings of Seoul Middle School Architecture in 1975 (1975년 서울시 중학교 표준설계도에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2497-2504
    • /
    • 2013
  • This study aims to analyze the 'Standard Drawings for School Facilities' issued by Seoul Education Committee in 1975 because it is the early example for middle school architecture. The results of this study are summarized as follows 1) In general trend of single-corridor type block plan, there are also changes in floor plan like no-corridor type block plan, $9.9{\times}6.6m$ classroom unit for the better daylight condition, built-in storage for students. 2) As for elevation design, it is characterized as daylight-oriented, functional exterior for without making full use of design elements. 3) Standardized dimensions are used as a rule in the height of story, ceiling, window sill and etc. Transitional characteristics of the early RC school architecture are found in exposed ceiling, incomplete insulation structure and mixed use of wood framed floor of earlier type. 4) Contrast to main school building, gymnasium shows the intend to express the symbolism of school architecture with diverse elevation design elements and the plasticity of building mass. 5) Separated plan of toilet and night-duty building also show the transitional characteristics. As conclusion, though showing the stereotyped school architecture, on the other hand, 'Standard Drawings for School Facilities' (1975) makes it possible to see the way of coping with the demands for school architecture in that time and the transition of school architecture. This is the main value of it as the material for the studies related to the history of educational facilities.

A Study on Landscaping Repair Work Classifications in Cultural Heritage Industry (문화재 수리의 조경분야 공종 분류에 관한 연구)

  • Kim, Min-Seon;Lee, Jae-Yong;Kim, Choong-Sik
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • The purpose of this study was to suggest the landscaping repair work classification, the standard for securing the independence of and establishing the scope of landscaping repair works. Standard construction specifications currently specify the landscaping repair work classification around the planting construction, while standard work estimate does not include the field of landscaping. The landscaping construction specifications and the standard work estimate in the construction industry should be, however, applied, so it is difficult to specifically understand what is the landscaping repair work classification in the cultural heritage industry. From 1961 to 1980, not only the tree planting but also a variety of landscaping facilities had been specified as the landscaping repair works, and it was found that all of these work classifications are established as the landscaping repair work classifications in the construction industry. A total of 20 work classifications were verified by comprehensively arranging those specified in notices of tender for working drawing services for cultural heritages during three years, from 2018 to 2020, except for those for the maintenance and Dancheong of architectures, plant protection and conservation. All 20 work classifications corresponded to the landscaping work classifications in the construction industry. On the basis of the landscaping work classifications in the construction industry, this study divided the landscaping repair work classifications into site-building and shaping, planting work, facility construction, paving work, ecological landscape architectural construction and vegetation maintenance, by considering the specialty of cultural heritage space.

Economics Analysis of Photovoltaic Power Generation Linked with Green Roof in Consideration of Seoul Solar Map-based RPS (서울시 햇빛지도 기반의 RPS제도를 고려한 옥상녹화 연계 태양광발전 시스템의 경제성 분석)

  • Kim, Tae-Han;Lee, So-Dam;Park, Jeong-Hyeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.77-82
    • /
    • 2017
  • In power supply systems for urban areas, issues such as a progressive tax have escalated recently. In this regard, photovoltaic power generation, which is appraised as an alternative power generation system, is drawing attention increasingly for its high stability and applicability to existing infrastructure. This study assessed the realistic feasibility of photovoltaic power generation and also analyzed the economic benefits expected when it is linked with green roof, which is likely to promote ecological functions in urban areas, based on the Seoul solar map, RPS, and actual monitoring data. The economics analysis of 30kW photovoltaic power generation applied with the monthly average horizontal solar radiation of six grades in the Seoul solar map showed that positive NPV was up to grade 4, while grade 5 or poorer showed negative NPV and indicated that it is difficult to assure appropriate feasibility. Compared with non-afforestation, when green roof was applied, monthly average power improvement efficiency was 7.2% at highest and 3.7% at lowest based on yearly actual monitoring data. The annual average was 5.3%, and the efficiency was high relatively in summer, including September and November. As for the economic benefits expected when 30kw photovoltaic power generation is combined with green roof based on the average horizontal solar radiation of grade 1 in the Seoul solar map, SP has improved 0.2 years to 7.4 years, and EP has improved 0.5 years to 8.3 years.

Development of Basic Construction Cost Estimation Model for Expansion of Underground Parking Lot Remodeling in Apartment Housing (공동주택 지하주차장 확대 리모델링 개략 공사비 산정 모델 개발)

  • Jeong, Eunbeen;Koo, Choongwan;Kim, Taewan;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.2
    • /
    • pp.42-52
    • /
    • 2021
  • The cost of remodeling parking lots of apartment houses accounts for about 20 percent of the total cost of remodeling. This means that when the remodeling cost of the underground parking lot is known, it becomes possible to estimate the total construction cost. The standard of estimation referenced when calculating the construction cost is difficult to apply to calculating the remodeling cost. Thus, a construction cost estimation model that reflects the characteristics of remodeling construction is necessary. This study developed a basic construction cost estimation model for expansion remodeling of underground parking lots of apartment houses that calculates the approximate cost of construction by reflecting the characteristics and design elements of remodeling. Based on literature review and consultation with experts, 37 activities of underground parking lot remodeling construction were derived. In order to enable calculation of approximate construction cost before the remodeling design drawing is finalized, the quantity calculation formula and unit price for each activity were presented. Based on expert advice, 13 factors that affect the increase in construction cost and weights of each factor were determined. As a result of applying three cases of remodeling complexes to the basic cost estimation model, the accuracy was confirmed to be 93 percent on average.