Comparative Analysis on Recommended Levels of Illumination in Korea·China·Japan: Focused on Recommended Levels of Illumination for Housing (한중일의 조도기준 비교분석 : 주택조도기준을 중심으로)

  • Song, DaeSun;Kang, HyeKyung;Jo, YoungMi;An, Okhee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • This study compared the recommended levels of illumination for housing. KS Recommended Levels of Illumination (KS A 3011) in Korea, Recommended Levels of Illumination (GB 50034-2004) in China and Recommended Levels of Illumination (JIS Z 9110) in Japan are compared. The results are as below. First, recommended levels of illumination used in Korea China Japan are suggested by different locations and activities. However, classification for application scope is set differently. There are 10 areas for classification used in Korea, 5 areas in China, and 13 areas in China. When medium levels for classification are included as classification level, total of 15 areas are used for classification in China. Second, when considering there are 15 areas of application scope in China for recommended levels of illumination, there are 7 areas that are commonly used in Korea China Japan. 7 areas include stadium, factories, hospitals, office, shopping center, houses and hospitals. Third, working surface is considered as the height for recommended levels of illumination in Korea China Japan. Korea and Japan consider all working positions, standing and sitting position, when deciding the height. However, China only considers the standing position. Fourth, application scope for recommended levels of illumination for housing are classified in 16 areas in Korea, 5 in China and 18 in Japan. Thus, the application scope for recommended levels of illumination in housing in Korea is similar to Japan. However, there are only 5 areas used in China such as living room, bedroom, dining room, kitchen and sanitary room. Fifth, recommended levels of illumination is classified in 3 levels such as Lowest-Moderate-Highest while China and Japan only have standard recommended levels of illumination. Sixth, when observing recommended levels of illumination by type of activities, Japan classified the activities in greatest detail followed by Korea and then China. Seventh, Recommended levels of illumination differs by each country.

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

A comparative analysis of gas and liquid phase standard spiked solid sorbent tubes for the determination of volatile organic compounds in indoor air by TD-GC/MS (열탈착/저온농축-GC/MS에 의한 실내공기 중 휘발성 유기화합물 정량용 기체상 및 액체상 표준물질 첨가한 고체 흡착관의 비교 분석)

  • Lim, Hyun-Woo;Jung, Sung-Won;Kang, Chul-Ho;Park, Jin-Sook;Park, Byeong Moo;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.287-297
    • /
    • 2013
  • The optimization of analytical method for the thermal desorption of seven VOCs (volatile organic compounds) by TD-GC/MS (thermal desorption-gas chromatograph-mass spectrometer) with solid phase sorbent tube, and comparative analysis for the determination of VOCs plotted by standard sorbent tubes prepared using both gas phase and liquid phase materials were investigated. The result of paired t-test showed that a liquid phase standard sorbent tube method was in agreement with a gas phase standard sorbent tube method for six species of VOCs including benzene, toluene, ethylbenzene, o-, m-, and p-xylene except for styrene at the significance level (${\alpha}=0.01$), while the 15.6% of difference in response factor between both of gas phase and liquid phase standard plotting for the determination of styrene showed that both methods were significantly different at the significance level. Therefore, the liquid phase standard plotting method was employed to reduce erroneous data for the determination of styrene including BTEX. Under the optimized analytical method by liquid phase standard sorbent tube, recovery was between $100{\pm}5%$ for 7 species of VOCs, reproducibility ranged from 0.3 to 7.7%, and method detection limit (MDL) ranged from $0.01{\mu}g/m^3$ for o-xylene to $0.27{\mu}g/m^3$ for toluene. The optimized standard method was applied to determine VOCs VOCs from indoor air of of dormitory, one bedroom apartment, and a new car.

A Study on Design Techniques of Palace Gardens presented in Donggwoldo (동궐도에 보이는 궁궐정원의 조영수법)

  • Chin, Sang-Chul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.4
    • /
    • pp.26-37
    • /
    • 2015
  • This paper aims to review all landscaping elements of Donggwoldo by building and identify the palatial garden landscaping characteristics and landscaping methods in a bid to explore landscaping methods applicable for modern-time gardens of Korea through Succession of Tradition. The research methodology was adopted by which the palatial gardens appearing in Donggwoldo were observed according to garden elements to identify their characteristics. Garden elements in Donggwoldo include oddly shaped stones, ponds, buildings and Madang, borders and areas, and trees. Their characteristics were analyzed, and as a result they are outlined as follows. Location : Buildings in Donggwoldo were located in the optimal areas within the Myungdang (the best location), with the building sites being created by transforming the natural topography positively according to the existing topography and uses. Tree planting : The construction of the buildings involved using the existing trees. There were no specific principle and method of planting trees, and no specific criteria for choosing the kind of tree. Symmetrical planting was adopted and its is considered embracing the viewpoint of making gardens based on the expression of Yin and Yang. Strongly symbolical kinds of trees were also adopted. Bangji : it takes a nearly circular shape in palatial gardens, and such shapes represent conceptual and abstract symbols. They were also frequently used as the place of public entertainment. Pavilions : they did not take a certain standard shape. They had diverse shapes, including a triangle, square, pentagon, hexagon, and octagon and cross. Oddly shaped stones : Oddly shapes stones and stone cases were deployed mainly near the bedroom and the crow prince's residence and in the rear garden. Hwagye : it appeared mainly in the back of the bedroom, the crown prince's residence, the princess's residence, and other women's quarters. Chwibyeong : it was installed for the purpose of drawing the natural energy like a natural inlet instead of being the nature-dividing wall. Korea's garden composition method was very different from the Western and Chinese method. Overall, Chosun palatial garden style was characterized by strict and Confucian features, while the garden construction method adopted the Taoism thought. Yet, the gardens had a carefree aspect.