• 제목/요약/키워드: Standard Apartment House

검색결과 105건 처리시간 0.025초

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • 국제초고층학회논문집
    • /
    • 제10권1호
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구 (A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges)

  • 김동수;윤종호;신우철;곽희열
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.

창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가 (Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea)

  • 임희원;김동윤;이수만;안정혁;윤종호;신우철
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

지역에 따른 주거용 건물에너지효율등급 분석 연구 (A Study on the Analysis of Building Energy Rating considering the Region)

  • 안병립;김지훈;김지연;장철용
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

청주시 아파트 일반가정의 겨울철 실내열·공기환경 현장측정조사 (The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City)

  • 조준행;최윤정
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.111-120
    • /
    • 2013
  • The purposes of this study were to investigate the actual state of the indoor thermal and air environment in general apartment houses during winter in Cheongju City, to analyze the related factors with the indoor thermal and air environment, and to make suggestions for the improvement. A series of visiting field investigation was conducted in twenty units between 28th December, 2010, and 11th March, 2011. The field investigations included the measurement of physical indoor environmental conditions, the observation of architectural characteristics and resident's behavior, and the on-site questionnaire survey of residents. The measured values of each units were compared to evaluation standard and were categorized to group by the difference between units. Factors related to the difference of the measured values between the groups were analyzed. The findings are summarized as followed. The indoor temperature of apartment houses during winter in Cheongju City was generally suitable. The relative humidity was slightly dry, while the $CO_2$ concentration was found to be excessively high. The factors related indoor environment were analysed as heating operation, ventilation, gas range use, and hanging out the wash to dry in indoors.

진동측정을 통한 공동주택 엘리베이터 소음 레벨 평가 (Evaluation of Elevator Noise level of Apartment Houses through Vibration Measurement)

  • 강민우;송민정;오양기
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.641-654
    • /
    • 2018
  • Elevator noise in apartment houses is one of the factors which prevent the residents from quiet and comfortable life. The elevator noise measurement method [KS F ISO 16032] is introduced from the matching ISO standard, however, it has problems in the application to the actual measurement. To visualize the problems, measurements in an apartment house are conducted, which has been suffering from the elevator noise for a long time. The measurement itself is extremely difficult due to the low sound pressure level of elevator, which is lower than 35 dB (A), and the even higher background noise level. However the vibration levels measured at the same time are relatively less disturbing As a result of vibration measurement, it was found that the vibration is clearly measured on the wall, and presents a high correlation coefficient of over 0.8 with the noise levels measured This shows that the vibration level measured on the elevator walls may be rather reliable numbers than the elevator noise levels in the actual noisy condition of elevator halls and the vicinity.

가격 영향요인 비교분석을 통한 노후 공동주택 맞춤형 리모델링의 사업성 분석 방법론 제안 (Analysis Methodology for Feasibility Study of Remodeling of Aged Apartment by Comparative Analysis of Price Influencing Factors)

  • 배병윤;김경래;신동우;차희성
    • 한국건설관리학회논문집
    • /
    • 제18권6호
    • /
    • pp.47-56
    • /
    • 2017
  • 2017년 현재 848만 세대가 공동주택에 거주하고 있고, 15년 이상 노후공동주택은 55.87%이다. 공동주택 리모델링 허용연한 기준은 15년 이상이므로 앞으로 공동주택 리모델링 시장은 계속해서 증가할 것이다. 리모델링 사업의 성공을 위해서 사업성 분석은 중요하지만 기존 신축 및 재건축의 사업성 분석방법이 리모델링 사업성 분석에 사용되고 있다. 그러므로 건축법에 의한 세대수 증가 없는 맞춤형 리모델링 사업성 분석에 관한 연구가 필요한 실정이다. 본고에서는 공동주택의 지가(地價)와 건물가의 형성에 영향을 미치는 요인을 도출하여 맞춤형 리모델링 사업의 사업성 분석 방법론을 개발하는 것을 목적으로 공동주택의 가격형성 개념에 따라 공시지가, 공시가격, 표준지가, 기준가격에 영향을 주는 요인을 사용한 노후 공동주택 맞춤형 리모델링 사업성 분석 방법을 제시하였고, 향후 개발된 계단가격법은 리모델링 사업진행단계에서 리모델링 주택조합 설립인가 후 시공자 선정 단계에서 활용 가능하다.

창호용 방충망의 성능기준 개선 방안 (Study on the improvement of the performance criteria for the Window Insect Screens)

  • 여인환;옥치열;안재홍;인기호;민병렬
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.61-64
    • /
    • 2009
  • The number of apartment houses has accounted for more than 50% of all domestic residential types in Korea since 1980s. However, the apartment house has environmentally disadvantageous conditions such as highly residential-density and potential falls by children aged seven years and under through windows. In this study, we aim to suggest some ideas to improve domestic performance assessment methods and criteria of window Insect screens for protection on security and fall prevention by analyzing domestic standard with several overseas codes related to the screens for windows.

  • PDF

공동주택단지 내 휘트니스 센터 시설현황 분석에 관한 연구 (The Present Status Analysis of Interior Planning in a Fitness Center Inside an Apartment Complex)

  • 조영연
    • 한국실내디자인학회논문집
    • /
    • 제14권4호
    • /
    • pp.87-94
    • /
    • 2005
  • Lately due to the sudden growth of the construction of an apartment complex in domestic market, many construction companies are eager to provide various public facilities to increase the apartment distribution rate. An introduction of a fitness center is popularized as a part of such development. There has been a continuing development in a private fitness based on analyzing the user's data. However a public fitness is quite different from the private in terms of a user's classification, preference rate, the pattern of use, and location which requires a different facility plan. Nevertheless, all these days a public fitness in an apartment house has been developed without a specific facility plan based on relevant materials. It is worried that such development would cause the facilities not to function as appropriate resident facilities and sink to idle ones. Therefore the purpose of this paper is to make the standard considered in facility planning in future and the base to guide an applying method. In the paper the present condition of fitness centers inside apartment houses has been compared to analyze the progress of the existing facilities and the appropriateness of the organization and the structure division. The result of the research shows that public resident facilities is not the place to perform passive role for fixed activities but one to form a community through the human relationship based on the facility. Therefore a fitness center inside the apartment complex have to be designed to provide service and leisure space as one of main community facilities for residents. To obtain this purpose, when choosing facilities of an apartment complex, first of all the residents' standard of living, apartment size, residents' distinction rate of age and sex, the needs of the times should be fully considered Secondly, the size of each facility space have to be decided based on the practical data analysis in facility use such as space preference, average staying time. Also, future living culture requires the change of the function and space according to the change of social values, so continuing research and data analysis are required to related to fitness center inside an apartment complex in order to present systematic approaching method and the paper will be expected to be a little step toward it.