• Title/Summary/Keyword: Staircase Test Method

Search Result 7, Processing Time 0.02 seconds

Design of the Staircase Fatigue Tests for the Random Fatigue Limit Model (확률적 피로한도모형하에서 계단형 피로시험의 설계)

  • Seo, Sun-Keun;Park, Jung-Eun;Cho, You-Hee;Song, Suh-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.35 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • The fatigue has been considered the most failure mode of metal, ceramic, and composite materials. In this paper, numerical experiments to asses the usefulness of two Dixon's methods(small and large samples) and 14 S-N methods on assumptions of lognormal fatigue limit distribution under RFL(Random Fatigue Limit) model are conducted for staircase(or up-and-down) test and compared by MSE(Mean Squared Error) and bias for estimates of mean log-fatigue limit. Also, guidelines for staircase test plans to choose initial stress level and step size are recommended from numerical experiments including sensitivity analyses. In addition, the parametric bootstrap method to construct a confidence interval for the mean of log-fatigue limit by the percentile method using a transition probability matrix of Markov chain is presented and illustrated with an example.

Evaluating Staircase Safety Using BIM-based Virtual Simulation: Focusing on the Elderly in the Republic of Korea

  • Yang, Hyuncheul;Jeong, Kwangbok;Kim, Sohyun;Lee, Jaewook
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1146-1153
    • /
    • 2022
  • As the population is aging, accidents involving elderly people are also increasing (2014:11,667 persons; 2018: 11,797 persons). In the case of the elderly population, falling accidents are the primary direct or indirect causes of death; in particular, they face an elevated risk of staircase falls. This study proposes a method of evaluating the safety of staircases using Building Information Modeling (BIM)-based virtual simulation. By making a virtual user with the behavioral characteristics of the elderly respond to a staircase in a BIM model, its safety performance can be evaluated. The evaluation criteria were derived from regulations, elements, and characteristics relevant to the safety of staircases. To validate the proposed method, safety evaluation tests were simulated on actual staircases. The evaluation result of the test simulation shows the safety scores of 1.97 points for the elderly user and 2.95 points for the average male adult user against a required safety score of a minimum of 2 points. That is, safety is relative to users as the safety of the same staircase can be different depending upon the different behavioral characteristics of users. The study suggests that the risk of staircase-related fall accidents to the elderly can be reduced by improving staircase designs through the proposed method.

  • PDF

Development of PC Double Wall for Staircase Construction (계단실 공사를 위한 PC Double Wall 공법 개발)

  • Suh, Jung-Il;Park, Hong-Gun;Hwang, Hyeon-Jong;Im, Ju-Hyuk;Kim, Yong-Nam
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.571-581
    • /
    • 2014
  • In the present study, hollow precast concrete wall (PC Double Wall) for staircase construction was developed. Comparing the conventional walls, the PC Double Wall can be reduced the lift weight using hollow core and improves the integrity between the PC members. The cross-section and re-bar details of the PC Double Wall were developed considering precast concrete manufacturing, constructability, and the structural safety. Particularly, a form system was developed to manufacture thin and hollow core PC wall efficiently. A mock-up test for a staircase using the PC Double wall was performed to verify the constructability and integrity of the PC walls. The test result verified that joint deformation and cracking did not occur as showing good constructability.

Prediction of Reliability of Fatigue Limit of S34MnV Steel for Marine Diesel Engine Crank Throw Components (선박용 디젤 엔진 크랭크 스로 부품용 S34MnV강의 피로한도에 대한 신뢰도 예측)

  • Kim, Seon Jin;Kong, Yu Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.751-757
    • /
    • 2016
  • The aim of this study is to estimate the reliability of fatigue limit of the material used for crank throw components according to the staircase method. The material used for crank throw components is forged S34MnV grade steel, which is heat treated by normalizing and tempering. In this work, to predict the reliability of the design fatigue strength, axially loaded constant amplitude fatigue testing was conducted. The test specimens were loaded with an axial push/pull load with a mean stress of 0 MPa, which corresponds to a stress ratio of R=-1. The fatigue test results were evaluated by Dixon-Mood formulas. The values of mean fatigue strength and standard deviation predicted by the staircase method were 296.3 MPa and 10.6 MPa, respectively. Finally, the reliability of the fatigue limit in some selected probability of failure is predicted. The proposed method can be applied for the determination of fatigue strength for design optimization of the forged steel.

Reliability Analysis in Fatigue Strength of Connecting Rod (커넥팅 로드의 피로강도에 대한 신뢰성 해석)

  • Kim, Cheol-Su;Lee, Jun-Hyeong;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1651-1658
    • /
    • 2001
  • It is necessary to evaluate fatigue strength and reliability of the connecting rod which is core part in automotive engine to assure the high level of durability of automobile. For this purpose, the loading conditions in automotive engine is obtained by the dynamic analysis. Based on these results, the critical section was identified by the finite element analysis. The fatigue strength under constant amplitude was evaluated and the mean of the fatigue limit at R = -2.27 derived from the staircase method was 311.2MPa. And the failure probability( F$\sub$p/ ) derived from the strength-stress interference model is 0.0003% at the 99.99% confidence level and the mean factor of safety was 4.2.

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

Attention-induced expansion in visual space (주의에 의한 시각 공간 확장)

  • 유명현;박정선;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.10 no.3
    • /
    • pp.51-66
    • /
    • 1999
  • Selective attention induces perceptual distortions. ranging from repulsion of objects located near the attended area(Suzuki & Cavanagh. 1997) to magnification of the u unattended objects (Tsal & Shalev. 1996). Two hypothetical mechanisms have been p postulated: a shift of receptive fields' positions away from the locus of attention(receptive-field-recruitment hypothesis) or the enlargement of perceived space around the a attended location(space-enlargement hypothesis). The present study distinguished between these hypotheses by investigating the spatial and temporal properties of attention-induced d distortions. Perceptual judgements on vernier alignment. line tilt. line length were used to measure attention-induced changes in perception. Attention was induced exogenously(by blinking a specific set of dots around the test stimuli} or endogenously(by instructing the subject to selectively attend the dots). After inducing attention. the test stimuli were briefly flashed. A staircase method was used to measure the attentional effect. A vertical line was perceived as repelled from the locus of attention. and a line segment appeared longer when attention was given to its vicinity. The effects decreased as the distance between the locus of attention or the time between the onset of attention and the stimulus presentation increased. The results imply that the space-enlargement hypothesis provides a better explanation for the attention-induced changes in perception than the receptive-field-recruitment hypothesis.

  • PDF