• Title/Summary/Keyword: Stagnation Pressure

Search Result 158, Processing Time 0.029 seconds

An Experimental Study of Supersonic Underexpanded Jet Impinging on a Perpendicular Flat Plate (평판 위에 충돌하는 초음속 과소팽창 제트에 관한 실험적 연구)

  • 이택상;신완순;이정민;박종호;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.53-61
    • /
    • 1999
  • Impinging jets are observed when exhaust gases from missiles or V/STOL aircrafts impinge on the ground, flame deflector, ship deck, etc. The flow shows different patterns according to the nozzle geometry, nozzle-to-plate distance, and plate angle, for example. This paper describes experimental works on the phenomena (pressure distribution, occurrence of stagnation bubble, and so on.) when underexpanded supersonic jets impinge on a perpendicular flat plate using a supersonic cold-flow system, and compares the results with those obtained using a shock tunnel. The flow characteristics for the supersonic cold-flow system were also investigated. Surface pressure distribution of supersonic cold-flow system differed from that of shock tunnel because of water and temperature in the low-pressure chamber. Surface pressure distribution as to underexpanded ratio showed similar patterns together.

  • PDF

Development of high performance and low noise compact centrifugal fan for cooling automotive seats (자동차 시트 쿨링용 고성능·저소음 컴팩트 원심팬 개발)

  • Kim, Jaehyun;Ryu, Seo-Yoon;Cheong, Cheolung;Jang, Donghyeok;An, Mingi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.396-403
    • /
    • 2018
  • In this paper, a high-performance and low-noise centrifugal fan is developed for cooling automotive seats which provide a driver with pleasant driving environment. First, the flow characteristics of the existing fan unit was analyzed using a fan performance tester and CFD (Computational Fluid Dynamics) simulations. The analysis of the predicted flow field indicated vortex flow near the tip of fan hub and stagnation flow on the top of fan hub. Two design points are devised to reduce the vortex flow and the stagnation flow observed in the existing fan unit. First, the cut-off clearance which is the minimum distance between the fan blade and the fan housing is increased to reduce the vortex strength and, as a result, to reduce the overall sound pressure level. Second, the hub shape is more modified to eliminate the stagnation flow. The validity of proposed design is confirmed through the numerical analysis. Finally, a prototype is manufactured with a basis on the numerical analysis result and its improved flow and noise performances are confirmed through the P-Q curves measured by using the Fan Tester and the SPL (Sound Pressure Level) levels measured in the anechoic chamber.

Efficacy and Adverse Events of Bangpungtongseong-san(Bofutsusho-san) and Bangkihwangki-tang(Boiogiot-tang) by Oriental Obesity Pattern Identification on Obese Subjects : Randomized, Double Blind, Placebo-controlled Trial (비만 환자에서 한방 비만 변증에 따른 방풍통성산과 방기황기탕의 치료효과 및 부작용 비교 : 무작위 배정, 이중 맹검, 위약-대조군 임상시험)

  • Park, Jung-Hyun;Lee, Myeong-Jong;Kim, Ho-Jun;Hong, Sun-woo;Lee, Dong-Ki;Yoo, Jae-Wook;Choi, Sun-Mi;Moon, Jin-Seok;Lim, Chi-Yeon;Lee, Jung-bok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.265-278
    • /
    • 2011
  • Objectives : This trial were conducted to evaluate the efficacy and adverse events of Bofutsusho-san(BTS) and Boiogiot-tang(BOT) by oriental obesity pattern identification on obese subjects, as compared to placebo. Methods : 166 subjects(body mass index ${\geq}25kg/m^2$) were recruited and randomized to receive BT(n=55), FH(n=55) or placebo(n=56) for 8 weeks. Anthropometric factors, serum lipid, glucose, blood pressure(BP), pulse rate, resting metabolic rate and oriental obesity pattern identification questionnaire were measured at baseline and 8 weeks. Adverse events and safety outcome variables were also checked during trials. Results : The frequency of top-scored oriental obesity pattern was ordered by indigestion(食積) > stagnation of the liver qi(肝鬱) > yang deficiency(陽虛) > spleen deficiency(脾虛) > phlegm(痰飮) > blood stasis(瘀血) in subjects. BTS group significantly decreased body weight, body mass index(BMI), waist circumference(WC), body fat mass, total cholesterol and HDL-cholesterol in stagnation of the liver qi(肝鬱) and WC in indigestion(食積). BOT group showed significant decrease of body weight, BMI, WC, and body fat mass in indigestion(食積) not in deficiency(虛症). Adverse events were reported most frequently in yang deficiency(陽虛) by BT group and stagnation of the liver qi(肝鬱) by BOT group. Conclusions : Bofu-tsusho-san was effective in treating obesity with stagnation of the liver qi(肝鬱). Obesity pattern identification could be a useful diagnostic tool predicting treatment effects and adverse events.

The effects of primary gas physical properties on the performance of annular injection type supersonic ejector (주유동 기체의 물리적 특성이 환형 분사 초음속 이젝터의 성능에 미치는 영향)

  • Jin, Jung-Kun;Kim, Se-Hoon;Park, Geun-Hong;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.12
    • /
    • pp.68-75
    • /
    • 2005
  • The effects of the physical properties of primary flow on the performance of a supersonic ejector were investigated. Axisymmetric annular injection type supersonic ejector was used for the study of the effects of molecular weight and the specific heat at constant pressure on the ejection performance. Test gases include; air, $CO_{2}$, Ar, $C_{3}H_{8}$, and $CCl_{2}F_{2}$ for different values of gas properties. As the molecular weight and CP of the primary gas increase, the secondary flow pressure increases at the same primary stagnation pressure and this behavior results from the combined effects of molar specific heat or specific heat ratio.

Numerical Simulation Study on Supersonic Combustion using the Cavity (공동을 이용한 초음속 연소의 수치적 연구)

  • Jeong, Eun-Ju;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.255-260
    • /
    • 2005
  • To achieve efficient combustion within a manageable length, a successful fuel injection scheme must provide rapid mixing between the fuel and airstreams. The aim of the present numerical research is to investigate the flame holding and combustion enhancement. Additional fuel into the cavity prevents shear flow impingement on the trailing edge of the cavity. The high temperature freestream flow mixes with the cold hydrogen fuel that is injected into the cavity and raises the fuel temperature remarkably and become to start combustion. The high pressure in the cavity due to the cavity structure and combustion leads the hydrogen fuel to upstream. The shock in the cavity to be generated by the fuel injection joins together and reflects off the ceiling wall. This makes high pressure and low mach number region and makes a small recirculation in this region. This high stagnation temperature is nearly recovered in the shear layer in front of the cavity and leads to start combustion. In the downstream of the cavity, the wall pressure drops significantly. This means that the combustion phenomenon is diminished. Because fuel lumps at the trailing edge of the cavity then it spreads after the cavity so, in this region there is a strong expansion.

  • PDF

Three-Dimensional Flow Analysis around Rolling Stock with Square Cross Section Using Low Re ${\kappa}-{\epsilon}$ (사각 단면을 갖는 철도차량 주위의 3차원 유동해석)

  • Jang, Yong-Jun
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.772-777
    • /
    • 2006
  • Three-dimensional numerical study is performed for the flow analysis around the rolling stock with square cross section (Mugungwha train model). The height (H) of rolling stock is considered as the characteristic length and the total length of rolling stock is 40 which correspond to 1/2 unit of rolling stock. The gap between the surface and rolling stock is 0.17H which is average value. The relative velocity between the surface and rolling stock is assumed to be zero and Re=10,000 based on the characteristic length. Low Re ${\kappa}-{\epsilon}$[15] is employed for the calculation of turbulence which resolve all the way to the solid surface (laminar sub-layer). Large flow separation occurred at the front head of train and a pair of vortex is generated on both top and side of rolling stock. The behavior of vortices on the top of the rolling stock is believed to affect the performance of the pantograph which should be intensively investigated. The difference between the high pressure in the front stagnation region of train and the low pressure in the rear separated region causes a large pressure drag. A large pair or vortex are generated in the rear of train and the size of vortex is increased more than the size of cross section of train.

Study of Spray Droplet/Wall Interaction (분무액적과 벽의 상호작용에 대한 연구)

  • 양희천;유홍선;정연태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.86-100
    • /
    • 1998
  • The impingement of the fuel spray on the wall within the combustion chamber in compact high-pressure injection engines and on the intake port wall in port-fuel-inje- ction type engines is unavoidable. It is important to understand the characteristics of impinging spray because it influences on the rate of fuel evaporation and droplet distrib- ution etc. In this study, the numerical study for the characteristics of spray/wall interaction is performed to test the applicability and reliability of spray/wall impingement models. The impingement models used are stick model, reflect model, jet model and Watkins and Park's model. The head of wall-jet eminating radilly outward from the spray impingement site contains a vortex. Small droplets are deflected away from the wall by the stagnation flow field and the gas wall-jet flow. While the larger droplets with correspondingly higher momentum are impinged on the wall surface and them are moved along the wall and are rolled up by wall-jet vortex. Using the Watkins and Park's model the predicted results show the most reasonable trend. The rate of increase of spread and the height of the developing wall-spray is predicted to decrease with increased ambient pressure(gas density).

  • PDF

KSR-III 매니폴드의 추진제 분사균일성 해석

  • Cho, Won-Kook
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.113-122
    • /
    • 2002
  • A numerical analysis on the uniformity of propellant injection velocity of KSR-III has been carried out to give design improvements. Injector holes were approximated as porous media with the same pressure drop . The injection velocity is higher at the opposite side of the inlet for both LOX and fuel due to the static pressure rise in the stagnation region. Flow passages at the vertical circular plate in the LOX dome increase the uniformity of LOX injection. Little change was observed in the injection uniformity and pressure drop for the slanted LOX passage. Also provided were the O/ F ratio distributions from the oxidizer/ fuel injection velocity analysis.

  • PDF

Numerical Modeling of Flow Characteristics within the Hyporheic Zones in a Pool-riffle Sequences (여울-소 구조에서 지표수-지하수 혼합대의 흐름 특성 분석에 관한 수치모의 연구)

  • Lee, Du-Han;Kim, Young-Joo;Lee, Sam-Hee
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.75-87
    • /
    • 2012
  • Hyporheic zone is a region beneath and alongside a stream, river, or lake bed, where there is mixing of shallow groundwater and surfacewater. Hyporheic exchange controls a variety of physical, biogeochemical and thermal processes, and provides unique ecotones in a aquatic ecosystem. Field and experimental observations, and modeling studies indicate that hyporheic exchange is mainly in response to pressure gradients driven by the geomorphological features of stream beds. In the reach scale of a stream, pool-riffle structures dominate the exchange patterns. Flow over a pool-riffle sequence develops recirculation zones and stagnation points, and this flow structures make irregular pressure gradient which is driving force of the hyporheic exchange. In this study, 3 D hydro-dynamic model solves the Reynolds-averaged Navier-Stokes equations for the surface water and Darcy's Law and the continuity equation for ground water. The two sets of equations are coupled via the pressure distribution along the interface. Simulation results show that recirculation zones and stagnation points in the pool-riffle structures dominantly control the upwelling and downwelling patterns. With decrease of recirculation zones, length of donwelling zone formed in front of riffles is reduced and position of maximum downwelling point moves downward. The numerical simulation could successfully predict the behavior of hyporheic exchange and contribute the field study, river management and restoration.

Numerical Analysis of Incompressible and Compressible Flow Around a Butterfly Valve (버터플라이 벨브 주위의 비압축성 및 압축성유동 특성에 대한 수치해석)

  • 이종욱;이두환;최윤호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • In this paper, incompressible and compressible flow characteristics around the butterfly valve have been investigated. In order to simplify the problem, a flat disk valve with various valve disk angles and pressure ratios is considered in the present calculations. It was found that as the disk angle increases, the stagnation point on the front surface of the disk moves to the center of the surface and the inflow velocity decreases. The maximum flow velocity occurs at the downstream of throat because of the formation of vents contracta. As the pressure ratio decreases, compressibility effects increase and the jet formed between the throttle body wall and the disk edge becomes supersonic. This flow also builds up as a shock cell structure. The increase of disk angle and pressure ratio makes the mass flow at the inlet decrease, while the increase of disk angle and the decrease of pressure ratio make the pressure loss coefficient increase.