• Title/Summary/Keyword: Stack current

Search Result 298, Processing Time 0.024 seconds

A log visualization method for network security monitoring (네트워크 보안 관제를 위한 로그 시각화 방법)

  • Joe, Woo-Jin;Shin, Hyo-Jeong;Kim, Hyong-Shik
    • Smart Media Journal
    • /
    • v.7 no.4
    • /
    • pp.70-78
    • /
    • 2018
  • Current trends in information system have led many companies to adopt security solutions. However, even with a large budget, they cannot function properly without proper security monitoring that manages them. Security monitoring necessitates a quick response in the event of a problem, and it is needed to design appropriate visualization dashboards for monitoring purposes so that necessary information can be delivered quickly. This paper shows how to visualize a security log using the open source program Elastic Stack and demonstrates that the proposed method is suitable for network security monitoring by implementing it as a appropriate dashboard for monitoring purposes. We confirmed that the dashboard was effectively exploited for the analysis of abnormal traffic growth and attack paths.

Analysis of the Deformed Unit Cell by Clamping Force Through the FEM and CFD Interaction (FEM과 CFD 연동을 통한 스택 체결 시 압력에 의해 변형된 단위 전지 해석)

  • YOO, BIN;LIM, KISUNG;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.228-235
    • /
    • 2021
  • Polymer electrolyte membrane fuel cells (PEMFC) are currently being used in various transport applications such as drones, unmanned aerial vehicles, and automobiles. The power required is different according to the type of use, purpose, and the conditions adjusted using a cell stack. The fuel cell stack is compressed to reduce the size and prevent fuel leakage. The unit cells that make up the cell stack are subjected to compression by clamping force, which makes geometrical changes in the porous media and it impacts on cell performance. In this study, finite elements method (FEM) and computational fluid dynamics (CFD) analysis for the deformed unit cell considering the effects of clamping force is performed. First, structural analysis using the FEM technique over the deformed gas diffusion layer (GDL) considering compression is carried out, and the resulting porosity changed in the GDL is calculated. The PEMFC model is then verified by a three-dimensional, two-phase fuel cell simulation applying the physical properties and geometry obtained before and after compression. The detailed simulation results showed different concentration distributions of fuel between the original and deformed geometry, resulting in the difference in the distribution of current density is represented at compressed GDL region with low oxygen concentration.

Humidification model and heat/water balancing method of PEMFC system for automotive applications (자동차용 연료전지 시스템의 가습모델과 열/물균형 유지방법)

  • Jung, Seung-Hun;Yoon, Seok-Ho;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.339-344
    • /
    • 2005
  • A PEMFC system model for FCEV was constructed and simulated numerically to examine the heat/water flow of the system and air/fuel humidification process for various operation conditions (ambient pressure /temperature/humidity, operating temperature, power load). We modeled PEMFC stack which can generate maximum electricity of about 80 kW. This stack consists of 400 unit cells and each unit cell has $250cm^2$ reacting area. Uniform current density and uniform operating voltage per each cell was assumed. The results show the flow characteristics of heat and water at each component of PEMFC system in macro-scale. The capacity shortage of the radiator occurred when the ambient was hot $(over\;40^{\circ}C)$ and power level was high (over 50 kW). In spite of some heat release by evaporation of water in stack, heat unbalance reached to 20kW approximately in such a severe operating condition. This heat unbalance could be recovered by auxiliary radiators or high speed cooling fan with additional cost. In cold environment, the capacity of radiator exceeded the net heat generation to be released, which may cause a problem to drop the operating temperature of stack. We dealt with this problem by regulating mass flow rate of coolant and radiator fan speed. Finally, water balance was not easily broken when we retrieved condensed and/or unused water.

  • PDF

A Study on Performance of Solid Oxide Fuel Cell Stack for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 스택 성능에 관한 연구)

  • Park, Sang-Kyun;Kim, Young-Jin;Roh, Gill-Tae;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.406-413
    • /
    • 2011
  • Recently the fuel cell has been spotlighted as a technology to reduce greenhouse gases emission from a ship. In this research, internal reforming 500kW solid oxide fuel cell stacks fueled by methane for a ship were developed. Characteristics of power and efficiency depending on the number of cells in the stack, hydrogen conversion ratio, and active area of the cell are evaluated. Also the effects of air and methane supplying conditions on performance are analyzed. As a result, as the number of cells, hydrogen conversion ratio, active area of the cell, or supplied air flow rate increase, the stack power and efficiency increase. When the methane flow rate increases, the power increases. However the efficiency decreases. In addition, the case at the current of 976.4 A, voltage of 529.1 V, with corresponding power of 516.6 kW shows that the efficiency of fuel cell stack is 42.91%.

A Study on Container Securing System for Optimum Arrangement (최적 적재를 위한 컨테이너 시큐어링 시스템 개발에 관한 연구)

  • Shin, Sang-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.4
    • /
    • pp.397-402
    • /
    • 2003
  • Generally, container arrangement has been carried out based on the Classification guidelines. However, guidelines provide only container securing forces for the given container arrangement and Classification requirements of the forces. In order to design container arrangement additional information is needed such as container securing forces and arrangement that accounts for lashing bridges, vertical lashing, vertical center of gravity (VCG), and maximum stack weight. Trial and error method using the existing guidelines requires excessive amount of calculation time and cannot provide accurate results of the calculations. In order to fulfill this need, a new container securing system has been established based on the equilibrium conditions that include lashing bridges and vertical lashing. An optimization algorithm has been developed for the new system since current optimization methods such as genetic algorithms and evolution strategies are unsuitable for the container securing problems, which involve equality constraint. Design variables are container weights of tier and objective function is either total container weight or VCG of a stack. The newly developed system provides optimum arrangement of containers for both maximum stack weight and maximum VCG. It also greatly reduces time for designing container arrangement.

A New High-Voltage Generator for the Semiconductor Chip

  • Kim Phil Jung;Ku Dae Sung;Chat Sin Young;Jeong Lae Seong;Yang Dong Hyun;Kim Jong Bin
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.612-615
    • /
    • 2004
  • A high-voltage generator is used to program the anti-fuse of the semiconductor chip. A new high-voltage generator consists of PN diodes and new stack type capacitors. An oscillator supply pulses to the high-voltage generator. The pulse period of the oscillator is delayed by controlling gate-voltage of the MOS. The pulse period is about 27ns, therefore the pulse frequency is about 37MHz. The threshold voltage of PN diode is about 0.8V. The capacitance of new stack type capacitor is about 4pF. The output voltage of the new high-voltage generator is about 7.9V and its current capacity is about $488{\mu}$A.

  • PDF

Dynamic Analysis of PEM fuel cell system (PEM 연료전지시스템의 동특성 해석)

  • Kim Beomsoo;Jeon Soonil;Lim Wonsik;Park Yeong-il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.353-356
    • /
    • 2005
  • We developed a dynamic model of PEM fuel cell system which can analyze its transient response to dynamic load current. System components such as compressor, air cooler, humidifier, and stack were modeled based on their dynamic equations and performance maps by using Matlab Simulink platform. Through this simulation model, dynamic characteristics of fuel cell system including oxygen excess rat io, stack voltage, and system efficiency were shown. In addition to that, we briefly analyzed the humidity effect on cathode pressure and system efficiency, expecting that this model can be further used to optimize fuel cell system parameters just like operating pressure and temperature, humidity and oxygen excess ratio.

  • PDF

Character Analysis of 1.2kW Proton Exchange Membrane Fuel cell (1.2KW 고분자 전해질형 연료전지 특성 분석)

  • Kim, Sung-Jun;Choi, Kyung-Tae;Choi, Kwang-Ju;Sugimura, Hisayuki;Lee, Hyun-Woo;Baek, Soo-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.288-291
    • /
    • 2005
  • This paper is aimed at presenting a proton exchange membrane (PEM) fuel cell stack. The fuel cell electrical output voltage and current (V-I) characteristic is described for the first time by a simplified closed form suitable. The characteristics obtained from the simulation are compared with the experimental results on a Ballard commercial fuel cell stack as well as to the manufacturer given data.

  • PDF

Quantitative identification of the fluxon-flow modes in a stack of intrinsic Josephson junctions of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+x}$ single crystals

  • Bae, Myung-Ho;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.9-12
    • /
    • 2003
  • We observed the splitting of the fluxon-flow branches in the current-voltage characteristics of serially stacked intrinsic Josephson junctions (IJJs) formed in $Bi_2$$Sr_2$$CaCu_2$$O_{ 8+x}$ single crystals in the long-junction limit. Stacks of IJJs were sandwiched between two Au electrodes deposited on the top and the bottom of the stack using the ‘double-side cleaving technique’. In all the samples studied, the branch splitting started occurring for a dense fluxon configuration around 2 T and became more distinct in a higher magnetic field range. This observation can be explained in terms of switching between different Josephson fluxon modes in resonance with the collective plasma oscillations induced by both inductive and capacitive coupling between stacked IJJs. This is the first detailed and quantitative identification of the coherent flux-flow modes in stacked..

  • PDF

Evaluation of Air Quality and Site Feasibility for the Construction of the Incineration Facilities in Won Ju City (원주시 소각시설의 입지와 주변지역의 대기질예측에 관한 연구 - 입지여건의 평가를 중심으로)

  • 송동웅;김기현
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.65-74
    • /
    • 2000
  • In this study, we investigated the site feasibility for the construction of the incineration facilities in Won Ju City. To assess the environmental impact of its construction, we examined the current status of air quality in the selected candidate sites and predicted the extent of air quality change upon its operation through modification of stack type. If the stack height is assumed to be 70 m, the concentrations of $SO_2$ and dioxin in the surrounding area were predicted to increase by 0.05 ppb and 0.09 pg/$m^3$, respectively. The impact of its operation was assessed and compared among different sites. According to this analysis, more impact was expected from the residential area for the Dan-Gye site than from agricultural areas of the Kwan-Sul and Sa-Je site.

  • PDF