• Title/Summary/Keyword: Stack cell

Search Result 584, Processing Time 0.024 seconds

Single Cell Stacked Planar Type SOFC Assembled Using a Ag-Current Collector (Ag 집전체를 적용한 평판형 SOFC 단전지)

  • Cho, Nam-Ung;Hwang, Soon-Cheol;Lee, In-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.12
    • /
    • pp.720-726
    • /
    • 2007
  • Current collectors of SOFC play a significant role on the performance of power generation. In this study a single cell stacked SOFC was assembled using Ag-mesh as a cathode current collector, and evaluated its performance. No gas leakages of the single cell stack occurred in the tests of gas detection and OCV measurement. The OCV and initial power of the stack were 1.09V and $0.45W/cm^2$, respectively, under the flow rates of air at 2,500 cc/min and $H_2$ at 1,000 cc/min at the test temperature of $750^{\circ}C$. A degradation rate of 44.0% was measured during the prolonged time of 307 h. The relatively low durability of the tested single cell stack was found to be the evaporation of Ag-mesh at the current corrector.

Humidification Optimization in Silicon-based Miniaturized Fuel Cell (실리콘으로 제작된 소형 연료 전지에서 가습 조건의 최적화)

  • Kwon, Oh-Joong;Won, Ho-Youn;Kim, Jae-Jeong
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2007
  • Single fuel cell was fabricated with a MEA (membrane electrode assembly) that had a $4cm^2$ active area and with silicon bipolar plates those were introduced to miniaturize the fuel cell by replacing heavy weight graphite plates. Optimum humidification condition for the single cell was selected based on performance results obtained varying humidifier temperature at a fixed feed rate of hydrogen and oxygen. Furthermore, to study the effect of humidification condition on the performance of a fuel cell stack, the fuel cell stack consisting of two MEAs and silicon bipolar plates was studied, then problems and characteristics of silicon-based fuel cell stack were examined.

Study about the development of voltage measurement device for fuel cell stack (연료전지 셀 전압 측정 장치 개발에 관한 연구)

  • Kirn, Tae-Hoo;Jung, Jae-Wook;Moon, Hee-Chun;Jeon, Ywun-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.569-572
    • /
    • 2007
  • In this paper, research about SVM(stack voltage monitoring) module is written, which studied to detect the failure mode of stack and stop stack driving. It is important role for SVM module to monitor the cell voltage and also, transfer those data to Supervisor controller. SVM module needs accurate measurement to detect failure mode, because the cell voltage is very small value under a few [V]. For improving these cost and technical efficiency, the electric characteristic experiment is made with the measurement circuit designed by using precision resistor.

  • PDF

TA Study on the Performance and the Efficiency in Polymer Electrolyte embrane Fuel Cell (고분자전해질형 연료전지의 성능해석 및 효율에 관한 연구)

  • Kim Hong-Gun;Kim Yoo-Shin;Yang Sung-Mo;Nah Seok-Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.75-80
    • /
    • 2005
  • An experimental study is carried out to investigate the performance and the efficiency humidifying Membrane Electrolyte Assembly and having the double-tied catalyst layers in a fuel cell system which is taken into account the physical and thermal concept. Subsequently, an electric output produced by PEMFC(Polymer Electrolyte Membrane Fuel Cell) is measured to assess the performance of a stack, and the efficiency is also evaluated according to the different situation in which unit cell is placed with and without the humidification of the MEA. It is found that the measured values of stack voltage and current are influenced by the stack temperature, humidification, and the double-tied catalyst layers which give more enhanced values to be applied to electric units.

Characterization of Fuel Cell Stack Using Hydrocarbon Polymer-Silica Composite Membranes (탄화수소계 고분자-실리카 복합막이 적용된 연료전지 스택 성능평가)

  • Hyun Woo Kang;Doo Sung Hwang;Chi Hoon Park;Young Moo Lee
    • Membrane Journal
    • /
    • v.33 no.3
    • /
    • pp.127-136
    • /
    • 2023
  • In this study, the electrochemical performance of a 5-layer fuel cell stack using silica composite membranes as polymer electrolyte membranes was evaluated. It was observed that the flow rate of the fuel gases plays a crucial role in stack performance, particularly being mainly dependent on the flow rate of hydrogen. Increasing the flow rate of oxygen resulted in negligible changes in performance, whereas an increase in the flow rate of hydrogen demonstrated performance improvements. However, this led to an imbalance in the ratio of hydrogen to oxygen flow rates, causing significant degradation in stack performance and durability. A decline in stack performance was also observed over time due to the degradation of stack components. This phenomenon was consistently observed in individual unit cells. Based on these findings, it was emphasized that, in addition to optimizing the performance of each component during stack operation, it is important to optimize design and operating conditions for uniform flow rate control. Lastly, the developed silica composite membrane was assessed to have sufficient performance for application in actual fuel cell systems, exhibiting a performance of over 25 W based on maximum power.

The Effect of Liquid Water in Fuel Cell Cathode Gas Diffusion Layer on Fuel Cell Performance (가스 확산층(GDL)내부의 물이 연료전지 성능에 미치는 영향)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.374-380
    • /
    • 2015
  • In this paper, a dynamic model describing the 2 phase effect on the gas diffusion layer depending on load change of a fuel cell stack was developed to examine the effects of liquid water in fuel cell cathode gas diffusion layer on the fuel cell performance. For the developed model, 2 phase effect on the performance of a fuel cell stack depending on the load changes, concentration distribution of water vapor and oxygen inside a gas diffusion layer, the effect of the thickness and porosity of the gas diffusion layer on the fuel cell stack voltage were examined. As a result, a fuel cell stack voltage for the 2 phase model within the scope of the research become lower than that for the 1 phase model regardless of the load. Although oxygen molar concentration for the gas diffusion layer adjacent to the catalyst layer was the lowest, water vapor concentration is the highest. In addition, as thickness and porosity of the gas diffusion layer increased and decreased, respectively, the fuel cell stack voltage decreased.

Cell Voltage Monitoring of PEMFC Power Module for Fuel Cell Electric Vehicle (연료전지 차량용 PEMFC 발전모듈의 셀전압 측정)

  • Park Hyunseok;Jeon Ywunseok;Ku Bonwoong;Choi Seoho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.388-391
    • /
    • 2005
  • In this paper, Cell voltage monitoring method is studied for fault detection of PEMFC(Proton Exchange Membrane Fuel Cell) for FCEV(fuel cell electric vehicle). To measuring several hundred of cells in fuel cell stack, The demanded feature of hardware and software is studied and several types are analysed. Finally, $3.26\%$ maximum measuring error is acquired and verified experimentally.

  • PDF

Study on Internal Reforming Characteristic of 1 kW Solid Oxide Fuel Cell Stack (1 kW 고체산화물 연료전지 스택의 내부개질 특성 연구)

  • CHOI, YOUNGJAE;AHN, JINSOO;LEE, INSUNG;BAE, HONGYOUL;MOON, JIWOONG;LEE, JONGGYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.377-383
    • /
    • 2017
  • This paper presents the performance characteristics of a 1 kW solid oxide fuel cell (SOFC) stack under various internal reforming and fuel utilization conditions. The Research Institute of Industrial Science & Technology (RIST) developed the 9-cell stack using a $20{\times}20cm^2$ anode supported planar cell with an active area of $324cm^2$. In this work, current-voltage characteristic test, fuel utilization test, continuous operation, and internal reforming test were carried out sequentially for 765 hours at a furnace temperature of $700^{\circ}C$. The influence of fuel utilization and internal reforming on the stack performance was analyzed. When the 1 kW stack was tested at a current of 145.8 A with a corresponding fuel utilization of 50-70% (internal reforming of 50%) and air utilization of 27%, the stack power was approximately 1.062-1.079 kW. Under continuous operation conditions, performance degradation rate was 2.16%/kh for 664 hours. The internal reforming characteristics of the stack were measured at a current of 145.8. A with a corresponding fuel utilization of 60-75%(internal reforming of 50-80%) and air utilization of 27%. As fuel utilization and internal reforming ratio increased, the stack power was decreased. The stack power change due to the internal reforming ratio difference was decreased with increasing fuel utilization.

Measurement and Analysis of Open Circuit Potential in PEFC (고분자 전해질 연료전지의 개방회로 전위차 측정 및 분석)

  • 김홍건;김유신;김홍열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.134-138
    • /
    • 2004
  • The discrepancies between theoretical values and measured data of PEFC(Proton Exchange Fuel Cell) is carried out for the machine tool power generation. Rudimental approach of theoretical fuel cell open circuit potential using Gibbs free energy is employed for the examination of PEFC module. The stack temperature, stack voltage and stack current are measured during the operation of PEFC module. It is found that stack voltage and current values show the pronounced discrepancy with the results calculated by Gibbs free energy approach. It is analysed that the discrepancy is due to activation polarization, concentration overvoltage and ohmic overvoltage.

  • PDF