• 제목/요약/키워드: Stable angle

검색결과 656건 처리시간 0.022초

Facile preparation of superhydrophobic thin films using non-aligned carbon nanotubes

  • Goh, Yee-Miin;Han, Kok Deng;Tan, Lling-Lling;Chai, Siang-Piao
    • Advances in nano research
    • /
    • 제2권4호
    • /
    • pp.219-225
    • /
    • 2014
  • A simple preparation method on creating superhydrophobic surface using non-aligned carbon nanotubes (CNTs) was demonstrated. Superhydrophobic CNT thin films were prepared by doping a sonicated mixture of CNTs and chloroform onto a glass slide. Water contact angles of the CNT thin films were measured using a contact angle goniometer. The thin films were characterized using laser microscope and scanning electron microscope. Experimental results revealed that the highest average contact angle of $162{\pm}2^{\circ}$ was achieved when the films' thickness was $1.628{\mu}m$. The superhydrophobic surface was stable as the contact angle only receded from $162{\pm}2$ to $157{\pm}2^{\circ}$ after 10 min under normal atmospheric condition.

SRFIMF를 이용한 멀티팬 부상기의 YAW제어에 관한 연구 (A Study on Yaw Control of Multi-Fan Hovering with SRFIMF)

  • 박선국;최부귀
    • 한국통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.361-370
    • /
    • 1992
  • 수직 이착륙기와 같은 비행체의 정지비행 도중 비행체의 위치각, 각속도, 각가속도와 같은 상태량을 궤환 시킨 SRFIMF(State Rate Feedback Implicit Model-Following)이론을 이용하여 4개의 팬을 갖는 부상제어시스템을 구성하였다. 이 부상제어시스템의 yaw제어를 행하여, 각 상태궤환이득 및 전향경로 이득을 변화시켜 부상제어시스템의 특정을 해석하였으며, 부상시스템과 같은 제어계에 SRFIMF방식을 적용시켜 그 타당성을 조사하였다.

  • PDF

CAD/CAE를 이용한 냉간 비조질강용 회전전조 금형설계 (Design of Cross Wedge Rolling Die for a Non-heat-treated Cold Steel using CAD and CAE)

  • 이형욱;윤덕재;이근안;최석우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.400-403
    • /
    • 2004
  • A non-heat기leafed steel does not need quenching and tempering processes that are called a heat treatment differently from conventional steel. Since the tensile strength of this steel is higher than 900MPa, a conventional forming process should be changed to incremental forming process such as a cross wedge rolling that requires lower load capacity than conventional ones. In this paper, the cold cross wedge rolling (CWR) die has been designed using CAD/CAE In order to produce near-net-shaped component of ball stud of non-heat-treated cold steel. Finite element analyses were applied in order to investigate process parameters of CWR. Results provide that the stretching angle and the forming angie at knifing zone in CWR process is important parameter to be the stable process under the low friction coefficient condition.

  • PDF

Simultaneous surgery for subcondylar fracture and prominent angle of the mandible

  • Jeong, Chang-Hwa;Ryu, Jae-Young;Lee, Woo-Yul;Kim, Hyeon-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.26.1-26.4
    • /
    • 2015
  • We experienced a patient of subcondylar fracture who had a squared contour of the lower face with prominent angle of the mandible and masseter hypertrophy. Our patient was increasingly seeking esthetic improvement of the lower third of the face. But she did not want multi-stage operations. Thus, we decided and performed a one-stage mandibular angle ostectomy with fracture management. We have a stable and esthetic result simultaneously despite fractures of the fixation plates during follow-up period, so report a case.

A Simulation Study on Regularization Method for Generating Non-Destructive Depth Profiles from Angle-Resolved XPS Data

  • Ro, Chul-Un
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.707-714
    • /
    • 1995
  • Two types of regularization method (singular system and HMP approaches) for generating depth-concentration profiles from angle-resolved XPS data were evaluated. Both approaches showed qualitatively similar results although they employed different numerical algorithms. The application of the regularization method to simulated data demonstrates its excellent utility for the complex depth profile system. It includes the stable restoration of the depth-concentration profiles from the data with considerable random error and the self choice of smoothing parameter that is imperative for the successful application of the regularization method. The self choice of smoothing parameter is based on generalized cross-validation method which lets the data themselves choose the optimal value of the parameter.

  • PDF

Influence of High PV Penetration and STATCOM on Rotor Angle Stability of SMIB Transmission System

  • Selwa, FETISSI;Djamel, LABED;Imen, LABED
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.849-857
    • /
    • 2018
  • This paper aims is to study the effect of photovoltaic generation penetration and STATCOM on the transient stability of a single machine infinite bus (SMIB) system based on the rotor angle stability. The influence of STATCOM and PV penetration can be seen through damping oscillations, so that the generator remains stable with the rest of the system for various fault conditions. The simulation results obtained make it possible to efficient identify harmful and beneficial impact of increasing the PV penetration and the existence of STATCOM capability. The system model is created in MATLAB/ SIMULINK software.

LCCL-S 토폴로지 특성을 이용한 전기자동차용 무선충전시스템의 ZPA 주파수 추종 제어 (Zero-Phase Angle Frequency Tracking Control of Wireless Power Transfer System for Electric Vehicles using Characteristics of LCCL-S Topology)

  • 변종은;이병국
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.404-411
    • /
    • 2020
  • Inductive power transfer (IPT) systems for electric vehicles generally require zero phase angle (ZPA) frequency tracking control to achieve high efficiency. Current sensors are used for ZPA frequency tracking control. However, the use of current sensors causes several problems, such as switching noise, degrading control performance, and control complexity. To solve these problems, this study proposes ZPA frequency tracking control without current sensors. Such control enables ZPA frequency tracking without real-time control and achieves stable zero voltage switching operation closed to ZPA frequency within all coupling coefficient and load ranges. The validity of the proposed control algorithm is verified on LCCL-S topology with a 3.3 kW rating IPT experimental test bed. Simulation verification is also performed.

Vertical Alignment of Nematic Liquid Crystal on the SiC Thin Film Layer with Ion-beam Irradiation

  • Oh, Yong-Cheul;Lee, Dong-Gyu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.301-304
    • /
    • 2006
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of the SiC (Silicon Carbide) thin film. The SiC thin film exhibits good chemical and thermal stability. The good thermal and chemical stability make SiC an attractive candidate for electronic applications. A vertical alignment of nematic liquid crystal by atomic beam exposure on the SiC thin film surface was achieved. The about $87^{\circ}$ of stable pretilt angle was achieved at the range from $30^{\circ}\;to\;45^{\circ}$ of incident angle. Consequently, the vertical alignment effect of liquid crystal electro-optical characteristic by the atomic beam alignment method on the SiC thin film layer can be achieved.

Application of direct tension force transfer model with modified fixed-angle softened-truss model to finite element analysis of steel fiber-reinforced concrete members subjected to Shear

  • Lee, Deuck Hang;Hwang, Jin-Ha;Ju, Hyunjin;Kim, Kang Su
    • Computers and Concrete
    • /
    • 제13권1호
    • /
    • pp.49-70
    • /
    • 2014
  • Steel fiber-reinforced concrete (SFRC) is known as one of the efficient modern composites that can greatly enhance the material performance of cracked concrete in tension. Such improved tensile resistance mechanism at crack interfaces in SFRC members can be heavily influenced by methodologies of treatments of crack direction. While most existing studies have focused on developing the numerical analysis model with the rotating-angle theory, there are only few studies on finite element analysis models with the fixed-angle model approach. According to many existing experimental studies, the direction of principal stress rotated after the formation of initial fixed-cracks, but it was also observed that new cracks with completely different angles relative to the initial crack direction very rarely occurred. Therefore, this study introduced the direct tension force transfer model (DTFTM), in which tensile resistance of the fibers at the crack interface can be easily estimated, to the nonlinear finite element analysis algorithm with the fixed-angle theory, and the proposed model was also verified by comparing the analysis results to the SFRC shear panel test results. The secant modulus method adopted in this study for iterative calculations in nonlinear finite element analysis showed highly stable and fast convergence capability when it was applied to the fixed-angle theory. The deviation angle between the principal stress direction and the fixed-crack direction significantly increased as the tensile stresses in the steel fibers at crack interfaces increased, which implies that the deviation angle is very important in the estimation of the shear behavior of SFRC members.

Research of the Mechanism of Low Frequency Oscillation Based on Dynamic Damping Effect

  • Liu, Wenying;Ge, Rundong;Zhu, Dandan;Wang, Weizhou;Zheng, Wei;Liu, Fuchao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1518-1526
    • /
    • 2015
  • For now, there are some low frequency oscillations in the power system which feature low frequency oscillation with positive damping and cannot be explained by traditional low frequency oscillation mechanisms. Concerning this issue, the dynamic damping effect is put forward on the basis of the power-angle curve and the study of damping torque in this article. That is, in the process of oscillation, damping will dynamically change and will be less than that of the stable operating point especially when the angle of the stable operating point and the oscillation amplitude are large. In a situation with weak damping, the damping may turn negative when the oscillation amplitude increases to a certain extent, which may result in an amplitude-increasing oscillation. Finally, the simulation of the two-machine two-area system verifies the arguments in this paper which may provide new ideas for the analysis and control of some unclear low frequency phenomena.