• Title/Summary/Keyword: Stable DC

Search Result 408, Processing Time 0.025 seconds

DC Magnetron Sputtering of Cr/Cu/Cr Metal Electrodes for AC Plasma Display panel (DC Magnetron Sputtering 법에 의한 AC Plasma Display panel의 Cr/Cu/Cr 금속전극 제조)

  • 남대현;이경우;박종완
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.704-710
    • /
    • 2000
  • Metal electrode materials for plasma display panel should have low electrical resistivity in order to maintain stable gas discharge and have fast response time. They should also hae good film uniformity adhesion and thermal stability. In this study Cr/Cu/Cr metal electrode structure is formed by DC magnetron sputtering. Cr and Cu films were deposited on ITO coated glasses with various DC power density and main pressures as the major parameters. After metal electrodes were formed a heat treatment was followed at 55$0^{\circ}C$ for 20 min in a vacuum furnace. The intrinsic stress of the sputtered Cr film passed a tensile stress maximum decreased and then became compressive with further increasing DC power density. Also with increasing the main pressure stress turned from compression to tension. After heat the treatment the electrical resistivity of the sputtered Cu film of 2${\mu}{\textrm}{m}$ in thickness prepared at 1 motor with the applied power density of 3.70 W/cm$^2$was 2.68 $\mu$$\Omega$.cm With increasing the main pressure the DC magnetron sputtered Cu film became more open structure. The heat treatment decreased the surface roughness of the sputtered Cr/Cu/Cr metal electrodes.

  • PDF

A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation (DC-link 전압변동을 고려한 PMSM 토크제어의 성능 향상 방법)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.112-122
    • /
    • 2014
  • This paper proposes a PMSM torque control method considering DC-link voltage variation and friction torque. In general EV/HEV application, two dimensions look-up table(2D-LUT) is used for reference current generation due to its stable and robust torque control performance. Conventionally, this 2D-LUT is established by flux-torque table to overcome the DC-link voltage variation. However, the flux table establishment is more complex than the speed table establishment. Moreover, one flux data reflects several speed conditions in variable DC-link voltage, friction torque cannot be considered by using the flux table. In this paper, speed-torque 2D-LUT is used for current reference generation. With this table, PMSM torque control is well achieved regardless of DC-link voltage variation by the proposed control method. Simulation and experimental results validate improvement of torque control error through friction torque compensation.

Autonomous Operation Analysis of DC Microgrid based on Droop Control (Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석)

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.342-350
    • /
    • 2011
  • This paper describes the autonomous operation analysis of DC microgrid based on droop control. In order to verify the whole system operation, detailed simulation models for wind power generation, solar power generation, and battery were developed with user-defined models programmed with C-code in PSCAD/ EMTDC software. The simulation results confirm that the DC microgrid with droop control make it feasible to provide power to the load with stable manner. Based on simulation results a prototype of DC microgrid was built and tested in the lab to verify the autonomous operation experimentally. The droop control scheme can suppress the circulating current, and offers each unit to be controlled autonomously without any communication link.

Design of a High-Efficiency CMOS DC-DC Boost Converter Using a Current-Sensing Feedback Method (전류 감지 Feedback 기법을 사용한 고효율 CMOS DC-DC Boost 변환기의 설계)

  • Jung Kyung-Soo;Yang Hui-Kwan;Cha Sang-Hyun;Lim Jin-Up;Choi Joong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.9 s.351
    • /
    • pp.23-30
    • /
    • 2006
  • This paper presents a design of a high-efficiency CMOS DC-DC boost converter using a current-sensing feedback method. High-precision current-sensing circuity is incorporated in order to sense the current flowing in the inductor, which determines the switching scheme of the pulse-width modulation. The external components or large chip area for the frequency compensation can be avoided while maintaining the stable operations of the converter. Various input/output voltage levels can be available through the external resistor strings. The designed DC-DC converter is fabricated in a 0.18-um CMOS technology with a thick-gate oxide option. The converter shows the maximum efficiency over 90% for the output voltage of 3.3V and load current larger than 200mA. The load regulation is 1.15% for the load current change of 100mA.

A Study on the Stable Sensorless Control of BLDC Motor Inside Auxiliary Air Compressor

  • Kim, In-Gun;Hong, Hyun-Seok;Go, Sung-Chul;Oh, Ye-Jun;Joo, Kyoung-Jin;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.466-471
    • /
    • 2017
  • Pantograph must be correctly attached to catenary to continuously supply stable power to railway vehicle, and the device used here is Auxiliary Air Compressor (ACM). The existing ACM used the DC motor that included commutator and brush. Since maintenance and repair by mechanical friction are essential for the DC motor, BLDC motor studies have been conducted to improve this. A three-phase BLDC motor does $120^{\circ}$ two-phase commutation through hall sensors in general. However, since hall sensor is vulnerable to heat and can run only when all three sensors work normally, sensorless control method has been studied to solve this. Using back EMF Zero Crossing Point (ZCP) detection method, this paper will introduce a stable switching sensing method that has a non-commutation area in a low speed zone.

Novel Topology and Control Strategy of HVDC Grid Connection for Open Winding PMSG based Wind Power Generation System

  • Zeng, Hengli;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.215-221
    • /
    • 2014
  • To satisfy the high voltage direct current (HVDC) grid connection demand for wind power generation system, a novel topology and control strategy of HVDC grid connection for open-winding permanent magnet synchronous generator (PMSG) based wind power generation system is proposed, in which two generator-side converter and two isolated DC/DC converters are used to transmit the wind energy captured by open winding PMSG to HVDC grid. By deducing the mathematic model of open winding PMSG, the vector control technique, position sensorless operation, and space vector modulation strategy is applied to implement the stable generation operation of PMSG. Finally, the simulation model based on MATLAB is built to validate the availability of the proposed control strategy.

Implementation of the Temperature Control System Using K-type Thermocouple (K형 열전대를 이용한 온도제어 시스템 구현)

  • Kim Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.3
    • /
    • pp.127-133
    • /
    • 2004
  • This study was carried out develope a temperature control system of temperature control by used K-thermocouple. This system was producted a stable voltage regulator 22Bit of digital converter and 22Bit of resolution. It was producted a micro voltage of 25 times amplification and controlled a DC0.1V~DC4.7V within 0~120$0^{\circ}C$. We designed block-diagram of hardware and software by PIC16C74 in a micro-controller, we are made up of a VFD function and can be used interface of a power block.

  • PDF

200mA low power DC-DC buck converter with 800nA quiescent current (800 nA Quiescent Current를 가지는 저전압 200mA 급 DC-DC Buck 변환기)

  • Heo, Dong-Hun;Kim, Ki-Tae;Kim, In-Seok;Nam, Hyun-Seok;Roh, Jeong-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.513-514
    • /
    • 2006
  • As power supply managements become more important than before, supplying a stable system voltage is becoming more and more critical. In this study we propose to use the advantage of weak inversion region of MOS transistors. Analog system, which uses weak inversion region, could work in low voltage environment and reduce power consumption. The proposed buck-converter in weak inversion region of MOS transistor has been verified by silicon chip.

  • PDF

Control Strategy of Smoothing Arc for DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Lee, Yongjoong;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.354-355
    • /
    • 2013
  • Fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed and applied for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. From the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Development of cooling system with sub-cooled nitrogen for DC Reactor of 6.6 ㎸-200A class HTS fault current limiter (6.6 ㎸-200A급 HTS 한류기 DC Reactor용 과냉질소 냉각시스템의 개발)

  • 김형진;권기범;강형구;배덕권;안민철;정은수;장호명;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.171-175
    • /
    • 2003
  • The sub-cooled nitrogen cooling system at 65 K with GM cryo-cooler is developed for cooling down the DC reactor of 6.6 ㎸-200 A class HTS Fault Current Limiter(SFCL). The sub-cooled nitrogen cooling is more economic than saturated nitrogen cooling, because the length of HTS wire is reduced in the same capacity, as well as, more stable. The cooling system with the GM cryo-cooler installed on the cryostat is not only compact but also efficient for energy saving. In the nitrogen vessel, after evacuating with vacuum pump to saturated nitrogen at 65 K, sub-cooled nitrogen at 65 K is made by putting in gas helium to 1 atm. During the short circuit test occurring the fault current of 1000 A, the sub-cooled nitrogen cooled DC reactor for SFCL is kept the state of sub-cooled nitrogen at 65 K.

  • PDF