• Title/Summary/Keyword: Stable DC

Search Result 408, Processing Time 0.026 seconds

Design of a High Stable Measuring Circuit for Radioactive Pulses (방사선 펄스의 고안정 계측회로 설계)

  • 송재용;한주섭;천상규;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF

Zeros and Step Response αlaracteristics in LTI SISO Systems (선형시불변 단일입출력 시스템의 영점과 계단응답 특성)

  • Lee, Sang-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.804-811
    • /
    • 2009
  • This paper deals with the relationship between zeros and step response of the second and third order LTI(Linear Time Invariant) SISO(Single-Input and Single-Output) systems. As well known, if a system has a single unstable zero, it shows the step response with undershoot and, on the other hand, a stable zero slower than the dominant pole causes the system to have the step response with overshoot. Generally, in the case of a system with two unstable real zeros, it is known to have B type undershoot[7]. But there are many complex cases of the step response extrema corresponding to zeros location in third order systems. This paper investigates the whole cases depending on DC gains of the additive equivalence systems and they are to be classified by the region of zeros which are related to the shape of the step response. Moreover, monotone nondecreasing conditions are proposed in the case of complex conjugate zeros as well as the case of two stable zeros.

Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses (방사선 펄스의 고안정 계측 및 분석기술 개발)

  • 손원진;김일권;한주섭;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.465-468
    • /
    • 2001
  • An objection of this study is to develop a high stable analytic system of radioactive pulses. The proposed system consists of an amplifying circuit with 60dB gain, a programmable power supply unit which can generate DC voltage up to 1, 500V, and a digital signal processor. Pulse height distribution in accordance with pulse counts is important data in analyzing radioactive pulses. In this study, AD convertor (12bit, l00ns) and DSP (TMS 320C31-60) are used to analyze the pulse height, and the analytic system is designed to be operated in PC-networking.

  • PDF

On Study for Improvement of The Inverter Welder (인버터 용접기의 전압손실 개선에 관한 연구)

  • Bae, Jong-Il;Lee, Dong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2063-2064
    • /
    • 2006
  • The power source of inverter welder stable power of low voltage and high current. Because if shouldn't be, it is caused to spark between the parent metal and the peak. So that, we designed to be base on high frequency transformer and reactor of DC part. Then, we optimized control of PWM, current rising slant, voltage, current, pulse current and inverter out-put voltage. Also we designed PCB for EMI and noises.

  • PDF

A control method and test results of utility interactive photovoltaic power generation systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 안교상;임희천;황인호;주형준
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

Design of Stabilization Algorithm for Unmanned Bicycle

  • Moon, Ji-Woon;Lee, Sang-Duck;Ham, Woon-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.51.3-51
    • /
    • 2001
  • In this paper, research of unmanned electric bicycle based on autonomic traveling is discussed. We derived dynamic equation of bicycle and introduced control theory that bicycle´s tilt angle and velocity is stable in some region. We implemented system using DSP processor, accelerometer and DC motor. Then, we carried out an experiment based on studied Control theory.

  • PDF

Design and Fabrication of SYNC Signal Separator IC (동기신호 분리용 집적회로의 설계 및 제거)

  • 장영욱;김영생;갑명철
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.6
    • /
    • pp.992-997
    • /
    • 1987
  • This paper describes the design and fabrication of an integrated circuit that can separate the horizontal SYNC., vertical SYNC. and composite SYNC. signal included in a composite video signal. The circuit that is based on the comparator level samplign method can separate a stable SYNC. signal even from an external circuit with large variation. It has been fabrivated by the SST bipolar process. Its chip size is 1.5x1.5mm\ulcorner As a result, we succeeded in fabrication of IC which satisfied DC characteristics and SYNC. singal separator function.

  • PDF

Characteristics of the closed microhollow cathode discharge for DC Plasma Display Panels

  • Park, Hae-Il;Noh, Joo-Hyon;Ryu, Byung-Gil;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.105-106
    • /
    • 2000
  • The positive slope of the current-voltage characteristic at pressure up to 850 torr was obtained using the closed microhollow cathode without the individual and/or distributed ballast. This indicates that the stable parallel operation of the discharge was also achieved using the closed microhollow cathode. The parallel operation makes it possible to manufacture de plasma displays with high pressure, small discharge current, and long lifetime.

  • PDF

A High Speed Distance Relaying Algorithm Based on a Least Square Error Method (최소자승법을 이용한 고속 거리계전 알고리즘)

  • Kwon, Tae-Won;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.208-210
    • /
    • 1998
  • A high speed digital distance relaying algorithm based on a modified least square error method is proposed. To obtain stable phasor values very Quickly, first, a lowpass filter which has very short transient period and no overshoot is used. Secondly, the conventional least square error method is modified to the one having the data window of 3 samples by applying a FIR filter which removes the DC-offset component in current relaying signals.

  • PDF

A Study on Adaptive Load Torque Observer for Robust Precision Position Control of BLDC Motor (적응제어형 외란 관측기를 이요한 BLDC 전동기의 정밀위치제어에 대한 연구)

  • 고종선;윤성구
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.4-9
    • /
    • 1999
  • A new control method for precision robust position control of a brushless DC (BLDC) motor using asymptotically stable adaptive load torque observer is presented in the paper. Precision position control is obtained for the BLDC motor system approximately linearized using the field-orientation method Recently, many of these drive systems use BLDC motors to avoid backlashe. However, the disadvantages of the motor are high cost and complex control because of nonlinear characteristics. Also, the load torque disturbance directly affects the motor shaft. The application of the load torque observer is published in [1] using fixed gain. However, the motor flux linkage is not exactly known for a load torque observer. There is the problem of uncertainty to obtain very high precision position control. Therefore a model reference adaptive observer is considered to overcome the problem of unknown parameter and torque disturbance in this paper. The system stability analysis is carried out using Lyapunov stability theorem. As a result, asymptotically stable observe gain can be obtained without affecting the overall system response. The load disturbance detected by the asymptotically stable adaptive observer is compensated by feedforwarding the equivalent current which gives fast response. The experimenta results are presented in the paper.

  • PDF