• Title/Summary/Keyword: Stability Rating Test

Search Result 44, Processing Time 0.021 seconds

Dynamic Model Based Ratio Calculation of Equivalent Reactance and Resistance of the Bulk Power Systems (동적모델을 이용한 대규모 전력계통의 등가 리액턴스와 저항 비율(X/R) 계산)

  • Kook, Kyung-Soo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2739-2746
    • /
    • 2011
  • This paper proposes the method for more effectively calculating X/R which is the ratio of equivalent reactance(X) and resistance(R) of the bulk power system and analyses the characteristic of X/R values by applying the proposed method to the real bulk power systems. X/R is used to determine the rating of the relay in the bulk power systems and its value has been accepted to be big enough to ignore the equivalent resistance of the bulk power systems. However, X/R is calculated as a big number when only the upper transformer and transmission line are considered. The correct approach to calculating X/R needs to consider all the parameters including generators, transformers, lines and loads. This paper calculates X/R of the bulk power systems using dynamic models which have been used to analyse the power system stability. The effectiveness of the proposed method is verified by applying it to the test system and X/R values of the real bulk power systems are analyzed. In addition, the dependence of X/R on the closeness of its calculating locations to the generator is verified by using the marginal loss factor which has been used in the electricity market.

Preparation of Silica Coated Zinc Oxide and UV Protection Effect (이산화규소가 코팅된 산화아연의 제조와 자외선 차단 특성)

  • Kim, Won Jong;Kang, Kuk Hyoun;Lee, Gi Yong;Kim, Tae Won;Choi, Jong Wan;Lee, Dong Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.2
    • /
    • pp.121-131
    • /
    • 2014
  • Due to the high UV light scattering effect of Zinc oxide (ZnO), it is frequently used in sunscreen skincare products. Recently ZnO coated with silica has been used in cosmetics to improve UV protection, texture, decreased photocatalytic activity, dispersibility and stability of the skin care product. In this study, we developed a ZnO composite powder coated with silica for the future application to skincare products to block UV rays that could cause photoaging. To improve consumer's satisfaction rating, we used ZnO microparticles which are widely used in the cosmetics industry. The silica was coated using hydrothermal method with sodium silicate and acid hydrolysis. UV protection of the composite powder was analyzed by UV-Vis and in-vitro test and the advantages for practical use of this powder as a skincare product were determined.

A Study on the Failure Cause of Large Scale Rock Slope in Limestone Quarries (석회석 광산에서 발생한 대규모 암반사면의 붕괴원인 분석에 관한 연구)

  • Lee, Sang-Eun;Kim, Hak-Sung;Jang, Yoon-Ho
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.255-274
    • /
    • 2014
  • The target of this study is large scale rock slope collapsed by around 7 pm on August, 2012, which is located at ${\bigcirc}{\bigcirc}$ limestone quarries of Gangneung city, Gangwondo. The slope prior to the collapse is formed as the height of about 200 m and the average inclination of $45^{\circ}$. The estimated amount of the collapse is about $1,500,000m^3$ with respect to the slope after the collapse. Geotechnical and field investigations such as boring, geophysical prospecting, surface geological survey, geological lineaments, borehole imaging, metric 3D imaging, experimental and field test, mining work by year, and daily rainfall were performed to find the cause of rock slope failure. Various analyzes using slope mass rating, stereonet projection, limit equilibrium method, continuum and non-continuum model were conducted to check of the stability of the slope. It is expected that the cause of slope failure from the results of various analysis and survey is due to the combined factors such as topography, rainfall, rock type and quality, discontinuities, geo-structural characteristics as the limestone cavity and fault zones, but the failure of slope in case of the analysis without the limestone cavity is not occurred. Safe factor of 0.66 was obtained from continuum analysis of the slope considering the limestone cavity, so the ultimate causes of slope failure is considered to be due to the influence of limestone cavity developed along fault zone.

Anterior Cruciate Ligament Reconstruction: Comparison of Bone-Patellar tendon-Bone Grafts with Hamstring Tendon Grafts (자가 슬개건과 자가 슬괵건을 이용한 전방십자인대 재건술의 비교)

  • Choi, Sung-Wook;Oh, In-Suk;Kim, Ryuh-Sup;Kim, Myung-Ku;Bae, Joo-Han;Park, Hae-Bong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of the arthroscopic reconstruction of ACL using autologous hamstring tendon and autologous bone-patellar tendon-bone. Materials and Methods: From January, 2000 to December, 2004, 120 patients underwent arthroscopic ACL reconstruction using autologous hamstring tendon(60 cases) and autologous bone-patellar tendon-bone(BPTB)(60 cases). The mean followed up period of hamstring tendon group was 42 months(range $24{\sim}69$ months) and patellar tendon group was 52 months(range $24{\sim}84$ months). At the time of the final follow up, sixty patients in each group were evaluated the results of physical examination, activity level, patients' satisfaction, functional status, and objective anteriror stability using KT-2000 arthrometer. Results: At the time of the final follow up we compared the two groups who had ACL reconstruction using either autologous hamstring tendon or BPTB, and the final results of the Lachman test showed negative, or mildly positive in 85%(51 cases) of the hamstring tendon group and 90%(54 cases) of the BPTB group. Pivot shift test indicated positive in both groups, 8%(5 cases) and 5%(3 cases) respectively and showed no statistically significant difference. The evaluation of the anterior laxity using the KT-2000 arthrometer revealed no significant difference in the hamstring and BPTB groups: differences less than 3 mm compared to the healthy side were 85%(51 cases) and 90%(54 cases)(p>0.05). The Lysholm score improved from a preoperative score of 51 to a postoperative score of 79.1 in the hamstring groups and from 52 to 82.2 in the BPTB groups. According to the IKDC rating system, 87%(52 cases) were normal or near normal in the hamstring group. In the BPTB group, 83%(50 cases) were normal or near normal. The Tegner score for the hamstring groups was 4.8 preoperatively and 7.1 at the final follow up, and the Tegner score for the BPTB groups was 4.5 preoperatively and 7.3 after the last follow-up. The anterior knee pain was found in 7%(4 cases) in the hamstring tendon group and 10%(6 cases) in the patellar tendon group. Conclusion: Arthroscopic ACL reconstruction using both the autologous hamstring tendon and the patellar tendon during their mid term follow up period demonstrated excellent results. However, the final results during their last follow up showed no statistically significant difference between the two groups.

  • PDF