• Title/Summary/Keyword: Stability Number

Search Result 2,054, Processing Time 0.024 seconds

Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number (CE형 증기발생기 전열관의 행열 변화에 따른 유체유발진동 특성)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.927-932
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3-MODI and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone with the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air (초음속 공기장에서 Bluff-Body를 이용한 안정화염의 특성과 구조)

  • Kim, Ji-Ho;Yoon, Young-Bin
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.147-153
    • /
    • 2002
  • Experimental investigations are performed on the stability and the structure of bluff-body stabilized hydrogen flames. The velocities of coflow air are varied from subsonic to supersonic velocity of Mach 1.8 and OH PLIF images and Schilieren images are used for analysis. Three characteristic flame modes are classified into three regimes with the variation of fuel-air velocity ratio; a jet like flame, a central-jet dominated flame and a recirculation zone flame. Stability curves are drawn to find the blowout regimes and to show that flame stability is improved by increasing the lip thickness of fuel nozzle that works as bluff-body. $Damk{\ddot{o}hler$ number is adopted in order to scale the blowout curves of each flame obtained at different sizes of the bluff-body and all blowout curves are scaled successfully regardless of its bluff-body size.

  • PDF

Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number (CE형 증기발생기 튜브의 행열 변화에 따른 유체유발진동 특성)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.390.2-390
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3 and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone which the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

Stability Analyses of Magnetic Levitation Tables Using Repulsions of Permanent Magnets (영구자석에 의한 반발형 자기부상 테이블의 안정성 해석)

  • Choe, Gi-Bong;Jo, Yeong-Geun;Tadahiko Shinshi;Akira Shimokohbe
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.36-42
    • /
    • 2002
  • This paper presents two actuators for levitation using repulsions of permanent magnet and two magnetic levitation tables using the actuators. Here, one actuator for levitation consists of one fixed magnet and one moving magnet, and the other actuator consists of two fixed magnets and one moving magnet. The moving part of the magnetic levitation table contains the moving magnets. repulsive forces caused by the permanent magnets are linearized, and then the equation of motion of the moving part of the table is derived. Using the equation of motion, stability conditions of the moving part are deduced. The stability conditions are analyzed for positional relations of the moving magnets and the minimum number of active control required for stable system. As a result, in the each case of magnetic levitation tables, the requirements for stabilization are expressed by the positional relations and the number of the active controls.

A Study on Buoyancy Effects in Double-Diffusive Convecting System(II) - Theoretical Study - (이중확산 대류계에서의 부력효과에 관한 연구(II) - 이론적 연구 -)

  • Hong, Nam-Ho;Kim, Min-Chan;Hyun, Myung-Taek
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.129-137
    • /
    • 1999
  • The time of the onset of double-diffusive convection in time-dependent, nonlinear concentration fields is investigated theoretically. The initially quiescent horizontal fluid layer with a uniform temperature gradient experiences a sudden concentration change from below, but its stable thermal stratification affects concentration effects in such way to invoke convective motion. The related stability analysis, including Soret effect, is conducted on the basis of the propagation theory. Under the linear stability theory the concentration penetration depth is used as a length scaling factor, and the similarity transform for the linearized perturbation equations. The newlly obtained stability equations are solved numerically. The resulting critical time to mark the onset of regular cells are obtained as a function of the thermal Rayleigh number, the solute Rayleigh number, and the Soret effect coefficient. For a certain value of the Soret effect coefficient, the stable thermal gradient promote double-diffusive convective motion.

  • PDF

Onset of Buoyancy-Driven Convection in a Fluid-Saturated Porous Layer Bounded by Semi-infinite Coaxial Cylinders

  • Kim, Min Chan
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.723-729
    • /
    • 2019
  • A theoretical analysis was conducted of convective instability driven by buoyancy forces under transient temperature fields in an annular porous medium bounded by coaxial vertical cylinders. Darcy's law and Boussinesq approximation are used to explain the characteristics of fluid motion and linear stability theory is employed to predict the onset of buoyancy-driven motion. The linear stability equations are derived in a global domain, and then cast into in a self-similar domain. Using a spectral expansion method, the stability equations are reformed as a system of ordinary differential equations and solved analytically and numerically. The critical Darcy-Rayleigh number is founded as a function of the radius ratio. Also, the onset time and corresponding wavelength are obtained for the various cases. The critical time becomes smaller with increasing the Darcy-Rayleigh number and follows the asymptotic relation derived in the infinite horizontal porous layer.

Financial Status of Elderly Households -to make a Financial Plan for Retirement Preparation- (재무계획 수립을 위한 노인가계의 재정상태 분석)

  • 김순미
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.10
    • /
    • pp.179-196
    • /
    • 1998
  • The purpose of this study was to analyze the financial status of Korean elderly households to make a financial plan for retirement preparation. The sample obtained from 1997 KHPS, consisted of 326 households of 55-64 aged and 210 households of 65 and over aged. Statistics employed for the analysis were frequencies, percentile, univariate analysis and logistic analysis. And Lorenz curve and Gini coefficient were used to compare the financial status. The results could be summarized as follows. First, total income, total expenditure, total debt and net worth of 55-64 aged group were higher than those of 65 and over group, while total asset of 55-64 aged group was similar to 65 and over group's Second, total expediture to total imcome ratio(R1) and total asset to total debt ratio(R4) of 55-64 aged group were higher than 65 and over group's, but net worth to minimum cost of living ratio(R2) and financial asset to monthly expenditure ratio(R3) of 65 and over group were higher than 55-64 aged group's . Third, R4's Gini coefficient was the highest and R1's Gini coefficient was the lowest among all Gini coefficients. Also, R1's and R4's Gini coefficients of 55-64 aged group were greater than 65 and over group's. ourth, variables affecting R1's stability of 55-64 aged group were household head's age, educatonal attainment and family type, while those of 65 and over group were household head's age, past economic experience and the number of children. There was no significant variable affecting R2's stability of 55-64 aged group, but there was only household head's pst economic experience affecting those of 65 and over group. The variable contributing to R3's stability of 55-64 aged group was residence while the variables of 65 and over group were household head's educational attainment, past economic experience and the number of children. The variables contributing to R4's stability of 55-64 aged group were the number of children and residence, and the number of children was one variable of contributing to R4's stability of 65 and over aged group.

  • PDF

Stability Number of Additionally Placed Armor Unit (Tetrapod) Covered on Existing Two-Layered Tetrapod Rubble Mound Structures: Pattern Placing Condition (기존 2층 피복 테트라포드 상부에 추가 거치되는 피복재(테트라포드)의 안정계수: 정적거치 조건)

  • Kim, Young-Taek;Lee, Jong-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.516-523
    • /
    • 2020
  • Since the aging of coastal structures have been increased, the researches about the reinforcements of the existing aged structures are needed. Especially, the existing armor units placed on rubble mound structures should satisfy the stability against the increased design wave conditions. However the researches about these design problems have not been performed. In this study, the hydraulic model tests to investigate the stability number about the additionally placed armor unit were conducted. The main armor unit is a Tetrapod. The test results showed that the stability number (Kd) for additionally placed armor units(Tetrapod) increased up to maximum 10% comparing with that for 2 layers tetrapod (Kd = 8) within these test conditions with the pattern placing for existing armor layers and the stable armor layer slope for the non overtopping condition.

The Stability Conditions, Performance and Design Methodology for the Positive Position Feedback Controller (양변위 되먹임 제어기의 안정성, 제어 성능 및 설계 방법)

  • Kwak, Moon-Kyu;Han, Sang-Bo;Heo, Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.3
    • /
    • pp.208-213
    • /
    • 2004
  • This paper is concerned with the theoretical estimation of the single-input single-output(SISO) positive position feedback(PPF) controller and the derivation of the stability conditions for the multi-input multi-output (MIMO) PPF controller. Although the stability condition for the SISO PPF controller was derived in the earlier works, the question regarding the performance estimation of the SISO PPF controller has never been studied theoretically. Hence, the SISO PPF controller for the single degree-of-freedom system was first investigated and then control parameters including gain, the filter frequency, and the damping factor of the PPF controller were analyzed in detail thus providing the design methodology for the SISO PPF controller. In the case of real structure. there are infinite number of natural modes so that some modes are to be controlled by a limited number of actuator and sensor. Based on the theoretical results on the SISO PPF controller, the stability condition for the multi-input multi-output PPF controller was derived when only the few number of modes are to be controlled. The control spillover problem is also discussed in detail.

Stability limits of premixed microflames at elevated temperatures (고온에서의 예혼합 초소형 화염의 연소안정한계 연구)

  • Kim, Ki-Baek;Lee, Kyoung-Ho;Hong, Young-Taek;Kwon, Oh-Chae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.158-165
    • /
    • 2006
  • In order to provide the database for designing microcombustors, the combustion characteristics of premixed methane and propane air microflames at normal and elevated temperatures and atmospheric pressure generated on a microtube were studied experimentally and computationally. The stability limits of premixed microflames and the propensity of the microflames near the stability limits were experimentally determined, while the structure of the microflame at the fuel-leanest limit was obtained using a two-dimensional CFD simulation with a reduced kinetic mechanism. For all the microflames, the stability limits were observed only in the fuel-rich region. Results also show substantial extension of stability limits with elevated temperature that is realistic condition for micro fuel processing and significant fuel dilution immediately near the tube exit due to a low Peclet number times Lewis number effect.