• Title/Summary/Keyword: Stability Limits

Search Result 354, Processing Time 0.027 seconds

AN IMMERSED BOUNDARY METHOD WITH FEEDBACK FORCING FOR SIMULATION OF FLOW AROUND AN ARBITRARILY MOVING BODY (임의로 움직이는 물체 주위의 유동 해석을 위한 피드백 강제 외력을 이용한 가상경계방법)

  • Shin, S.J.;Huang, W.X.;Sung, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.23-29
    • /
    • 2007
  • We present an improved immersed boundary method for computing incompressible viscous flow around an arbitrarily moving body on a fixed computational grid The main idea is to incorporate feedback forcing scheme of virtual boundary method with Peskin's regularized delta function approach in order to use large CFL number and transfer quantities between Eulerian and Lagrangian domain effectively. From the analysis of stability limits and effects of feedback forcing gains, optimum regions of the feedback forcing are suggested.

  • PDF

Collocation of Sensor and Actuator for Active Control of Sound and Vibration (능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구)

  • 이영섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.778-783
    • /
    • 2003
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered, but this pair suffers from the in-plane motion coupling problem with the out-of$.$plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFB control. As a new alternative, a point sensor and piezoelectric actuator pair is also considered, which provides SPR property in all frequency range except at the first resonance in very low frequency. This non-SPR resonance could be minimized by applying a phase lag compensator.

  • PDF

The Stability Analysis of Power System Installed Superconducting Fault Current Limiter (고온 초전도 한류기가 설치된 전력 시스템의 안정도 해석)

  • Lee, Seung-Je;Lee, Chan-Ju;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.5
    • /
    • pp.227-232
    • /
    • 1999
  • The stability of Power system installed Hi-Tc Superconducting Fault Current Limiter(SFCL) is analyzed as a process of developing SFCL. For investigation, a simple mimic system(only one generator) is assumed and then the circuit with SFCL in that system is solved for transient performance. In case the SFCL is installed in the power system, it protected synchronization more effectively both in symmetrical 3-phase fault and single phase line to ground fault in that the machine remains in synchronism for the more time than of without superconducting fault current limiter. It shows that the superconducting fault current limiter not only limits fault current but also protest synchronism. So for design of this SFCL, its synchronism protection property must be considered.

  • PDF

Review of Entrainment and Interfacial Stability in Thermosyphons and Capillary-Driven Heat Pipes

  • Kim, B.H.;Kim, C.J.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 1998
  • Entrainment in thermosyphons and heat pipes was characterized in view of the interfacial stability associated with the critical Weber number and the entrainment limit at the onset of liquid entrainment from the liquid or wicked interface. Both literature review and theoretical analysis on the entrainment models were peformed in order to evaluate accuracy of the predicted value. For this purpose, the models were categorized in two groups according to their entrainment mechanism and interfacial configurations, i.e., the wave-induced entrainment and the shear-induced entrainment, respectively. Thus, the twelve models(five models for the wave-induced entrainment and seven for the shear induced entrainment) were examined to obtain individual trends and their discrepancies from the general tendency of the overall models. As a result, the critical Weber numbers and entrainment limits were calculated and represented as a function of vapor temperature for the chosen characteristic dimensions of the interface.

  • PDF

Control Strategies of Both the Heater Temperature and the Inverter Output Voltage of a Single-Phase PWM Inverter Systems for Heat Treatment (열처리용 단상 PWM인버터시스템의 히터온도 및 인버터 출력전압 제어기법)

  • Yang, Si-Gyeong;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1047-1054
    • /
    • 2018
  • This paper proposed the strategies for controlling both the heater temperature and the output voltage of a single-phase inverter for the heat treatment. The single-phase inverter system for the heat treatment controls the heater temperature to its reference one, and also it limits the inverter output voltage to 60 V for safety. The stability may be deteriorated due to the large time constant difference between the heater temperature and inverter output voltage. In order to ensure the stability, a hysteresis on/off control approach for the heater temperature control is adapted, and both the open-loop and the closed-loop control strategies of the output voltage are suggested. The performances for the proposed strategies are demonstrated with the experiments.

An Interior Point Method based Reactive Optimal Power Flow Incorporating Margin Enhancement Constraints

  • Song Hwa-Chang;Lee Byong-Jun;Moon Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.152-158
    • /
    • 2005
  • This paper describes a reactive optimal power flow incorporating margin enhancement constraints. Margin sensitivity at a steady-state voltage instability point is calculated using invariant space parametric sensitivity, and it can provide valuable information for selection of effective control parameters. However, the weakest buses in neighboring regions have high margin sensitivities within a certain range. Hence, the control determination using only the sensitivity information might cause violation of operational limits of the base operating point, at which the control is applied to enhance voltage stability margin in the direction of parameter increase. This paper applies an interior point method (IPM) to solve the optimal power flow formulation with the margin enhancement constraints, and shunt capacitances are mainly considered as control variables. In addition, nonlinearity of margin enhancement with respect to control of shunt capacitance is considered for speed-up control determination in the numerical example using the IEEE 118-bus test system.

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of Voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • v.11 no.X00
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

A Study on the Superconducting Fault Current Limiter in the Simple $3{\phi}$ Power System (유도형 고온 초전도 한류기의 단순 3상 계통 적용에 대한 연구)

  • Lee, S.J.;Joo, M.S.;Lee, C.J.;Lee, J.K.;Ko, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.253-255
    • /
    • 1997
  • This paper, which is one of the researches to limit high fault-current, treats the application of an inductive High Tc Superconducting Fault Current Limiter(HTSFCL) to distribution systems. In case that the inductive HTSFCL is applied to distribution systems, this paper presented the usefulness and the commercial possibility of it through computer simulation. If the inductive HTSFCL is established in distribution systems, after fault, it limits fault current effectively within a few millisecond, so it contributes to stability of power distribution system. Especially as the system with the HTSFCL is compared with the system without it, the system is improved in stability.

  • PDF

Instability of pipes and cables in non-homogeneous cross-flow

  • Riera, Jorge D.;Brito, J.L.V.
    • Wind and Structures
    • /
    • v.1 no.1
    • /
    • pp.59-66
    • /
    • 1998
  • The vibrations of bodies subjected to fluid flow can cause modifications in the flow conditions, giving rise to interaction forces that depend primarily on displacements and velocities of the body in question. In this paper the linearized equations of motion for bodies of arbitrary prismatic or cylindrical cross-section in two-dimensional cross-flow are presented, considering the three degrees of freedom of the body cross-section. By restraining the rotational motion, equations applicable to circular tubes, pipes or cables are obtained. These equations can be used to determine stability limits for such structural systems when subjected to non uniform cross-flow, or to evaluate, under the quasi static assumption, their response to vortex or turbulent excitation. As a simple illustration, the stability of a pipe subjected to a bidimensional flow in the direction normal to the pipe axis is examined. It is shown that the approach is extremely powerful, allowing the evaluation of fluid-structure interaction in unidimensional structural systems, such as straight or curved pipes, cables, etc, by means of either a combined experimental-numerical scheme or through purely numerical methods.

Changes of postural stability according to ankle fixation in healthy subjects

  • Jeong, Su-Hyeon;Mun, A-Young;Lee, Song-Eun;Kim, Min-Ju;Lee, Hui-Jin;Baek, Kook-Bin;Cho, Ki Hun
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Objective: The purpose of this study was to examine the changes in postural stability according to ankle fixation in healthy university students. Design: Cross-sectional study. Methods: Thirty healthy subjects (15 males and 15 females, 20.13 years, 167.49 cm, 65.87 kg) were recruited on a voluntary basis. The BT4 system (HUR Laps Oy, Tampere, Finland) was used to measure the static (standing posture with eyes open and eyes closed) and dynamic (external perturbation and limits of stability (LOS) in the forward, backward, left, and right side) balance abilities. External perturbation was measured by the subject's postural sway velocity and area for 20 seconds after being impacted by a gym ball. Static and dynamic stabilities were measured with ankle joint fixation and non-fixation conditions. Ankle fixation was provided using Mueller tape on both ankle joints. Results: For static stability under the standing posture, there was no significant difference between standing with ankle joint fixation and non-fixation conditions. However, dynamic stability (external perturbation and LOS in the forward, backward, left, and right side) was significantly higher in the standing with the non-fixation condition compared to the standing with ankle joint fixation condition (p<0.05). Conclusions: Our results reveal that ankle joint fixation can influence dynamic stability during standing. Thus, we believe that this result provides basic information for making improvements in postural control and may be useful in balance training for fall prevention.