• Title/Summary/Keyword: Square pulse

Search Result 259, Processing Time 0.029 seconds

The Effect of Hand Massage on the Anxiety of the Hysterectomy Patients in Immediately prior to Surgery (손마사지가 자궁절제술 환자의 수술직전 불안에 미치는 효과)

  • 김정미
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.2
    • /
    • pp.476-487
    • /
    • 2000
  • The purpose of this study was to examine the effects of hand massage as a nursing intervention on the anxiety of the hysterectomy patients in immediately prior to surgery. The method of this study was Nonequivalent Control Group Non-Synchronized Design. The data were selected from at K university hospital in Pusan, and they consisted of Experimental group-25 patients, Control group -24 patients. The data were collected from Jan. 4 to Jan. 30 in 1999. The subjects′ self-reports of anxiety (measured by the Spielberger Trait-State anxiety Inventory and Visual Analogue Scale developed by Cline et al.) were recorded before and immediately after the intervention. The objective physiologic measures of blood pressure and pulse rate. The collected data were analysed by means of frequency, percentage, standard deviation, chi- square test, t-test, ANCOVA with SPSS program. The results of this study were as following; 1. Hypothesis 1: The 1st hypothesis that "There will be significant difference of the state anxiety level just before surgery in the experimental group and control group" was supported(P= .000). 2. Hypothesis 2: The 2nd hypothesis that "There will be significant difference of the visual analogue scale score just before surgery in the experimental group and control group"was supported(P= .000). 3. Hypothesis 3: The 3rd hypothesis that "There will be significant difference of the systolic and diastolic blood pressure level just before surgery in the experimental group and control group"was supported (P= .003, P= .041). 4. Hypothesis 4: The 4th hypothesis that "There will be significant difference of the pulse rate just before surgery in the experimental group and control group"was supported(P= .004). In conclusion, hand massage is a benefical nursing intervention that alleviates the psychological, physiological anxiety of the hysterectomy patients in immediately prior to surgery. therefore it is recomended to use the hand massage as a nursing intervention for patients undergoing anxiety. The results of this study appear promising, additional research is recomended to further the appropriate uses of hand massage in nursing practice for this and other patient population.

  • PDF

Solid State Joining Processes for Dissimilar Joints of Mg/Al Alloys (고상접합을 이용한 Al/Mg 합금의 이종 용접)

  • Kim, Heung-Ju;Kim, Wook-Seong;Chun, Chang-Keun;Chang, Woong-Seong
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.41-41
    • /
    • 2009
  • To evaluate the applicability of dissimilar joining between Mg and Al alloys in automobile manufacturing process, solid state joining processes such as magnetic pulse welding(MPW), friction stir welding(FSW) and friction spot joining(FSJ) were attempted successfully. MPW process has been concentrated mainly on round section tube to tube and tube to bar welds. AZ31 Mg alloy has been successfully welded to pure Al A1070 as well as to Al alloy A3003. While, for friction stir welding of dissimilar sheet joints, AZ31B/A6061 with the thickness of 2mm were used and a square butt joint with a good quality was obtained at the conditions of 0.8mm/sec of travel speed and tool rotation speed of 850rpm. The maximum tensile strength of 179 MPa, which was about 80 % of the Mg base metal tensile strength, has been obtained. Finally, friction spot joining was attempted to make a dissimilar lap joint between AZ31(0.8mm) and A6061(1mm), while the joint exhibited the same level of tensile shear strength as that of similar Mg joint.

  • PDF

Effect of Ultrasound Therapy at the ST11 on Sympathetic Nervous System Change: A Prospective Randomized Controlled Study (기사혈(氣舍穴, ST11)에 적용한 혈위 초음파요법이 교감신경계에 미치는 영향: 전향적 무작위 대조군 연구)

  • Shinwoo Kang;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.167-184
    • /
    • 2023
  • Objectives This study was designed to assess the effectiveness of ultrasound therapy at the ST11 for regulation of sympathetic hyperactivity. Methods Forty healthy adult subjects were assigned to experimental group and control group. After taking mental stress, ultrasound therapy was applied at the ST11 in experimental group and sham-ultrasound therapy was applied in control group. The evaluation of sympathetic activity was measured by blood pressure, pulse rate, and heart rate variability at 3 times (Time 1: before the stress stimulation, Time 2: after the stress stimulation, Time 3: after the intervention). The primary end point was consisted of normalized (norm) low frequency (LF)/high frequency (HF) ratio, LF (norm), HF (norm). The secondary end point was consisted of systolic blood pressure, diastolic blood pressure, pulse rate, mean heart rate, standard deviation of NN intervals, root mean square of the successive differences, total power (log). Results After the stress stimulation, all subjects showed sympathetic hyperactivity. After the intervention, the experimental group showed lower sympathetic activity than the control group. Comparing the Time 3 and Time 1, the experimental group showed no significantly differences in sympathetic activity while the control group showed higher sympathetic activity in Time 3 than Time 1. Comparing the Time 3 and Time 2, the experimental group showed lower sympathetic activity in Time 3 than Time 2 while the control group showed higher sympathetic activity in Time 3 than Time 2. Conclusions We suggest that the ultrasound therapy at ST11 can decrease sympathetic activity in sympathetic hyperactivity condition.

Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina (정상 망막과 변성 망막을 위한 전기자극 파라미터)

  • Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium launched for developing retinal prosthesis. One of the prerequisites for the success of retinal prosthesis is the optimization of the electrical stimuli applied through the prosthesis. Since electrical characteristics of degenerate retina are expected to differ from those of normal retina, we performed voltage stimulation experiment both in normal and degenerate retina to provide a guideline for the optimization of electrical stimulation for the upcoming prosthesis. After isolation of retina, retinal patch was attached with the ganglion cell side facing the surface of microelectrode arrays (MEA). $8{\times}8$ grid layout MEA (electrode diameter: $30{\mu}m$, electrode spacing: $200{\mu}m$, and impedance: $50k{\Omega}$ at 1 kHz) was used to record in-vitro retinal ganglion cell activity. Mono-polar electrical stimulation was applied through one of the 60 MEA channel, and the remaining channels were used for recording. The electrical stimulus was a constant voltage, charge-balanced biphasic, anodic-first square wave pulse without interphase delay, and 50 trains of pulse was applied with a period of 2 sec. Different electrical stimuli were applied. First, pulse amplitude was varied (voltage: $0.5{\sim}3.0V$). Second, pulse duration was varied $(100{\sim}1,200{\mu}s)$. Evoked responses were analyzed by PSTH from averaged data with 50 trials. Charge density was calculated with Ohm's and Coulomb's law. In normal retina, by varying the pulse amplitude from 0.5 to 3V with fixed duration of $500{\mu}s$, the threshold level for reliable ganglion cell response was found at 1.5V. The calculated threshold of charge density was $2.123mC/cm^2$. By varying the pulse duration from 100 to $1,200{\mu}s$ with fixed amplitude of 2V, the threshold level was found at $300{\mu}s$. The calculated threhold of charge density was $1.698mC/cm^2$. Even after the block of ON-pathway with L-(1)-2-amino-4-phosphonobutyric acid (APB), electrical stimulus evoked ganglion cell activities. In this APB-induced degenerate retina, by varying the pulse duration from 100 to $1200{\mu}s$ with fixed voltage of 2 V, the threshold level was found at $300{\mu}s$, which is the same with normal retina. More experiment with APB-induced degenerate retina is needed to make a clear comparison of threshold of charge density between normal and degenerate retina.

  • PDF

High-Precision Ranging Scheme based on Multipath Delay Analysis in IR-UWB systems (IR-UWB 시스템에서 다중경로 지연시간 분석을 통한 고 정밀 거리추정)

  • Jeon, In-Ho;Kim, Young-Ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9C
    • /
    • pp.778-785
    • /
    • 2010
  • This paper proposes a high-precision ranging scheme based on channel estimation technique and multipath delay analysis in IR-UWB systems. When the IR-UWB signal is transmitted and received, the high-precision ranging is estimated with the time-of-arrival information of the signal. In the proposed scheme, the channel estimation process with the minimum mean square error technique or zero forcing technique is performed and the overlapped multipath within the pulse is analyzed with matrix pencil (MP) algorithm to achieve the ranging accuracy of centimeters. The performance of proposed scheme is evaluated with various IEEE 802.15.4a channel models and the relationship between the ranging performance and the computational complexity is analyzed in terms of the MP parameter values.

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

Cardiovascular response to surprise stimulus (놀람 자극에 대한 심혈관 반응)

  • Eom, Jin-Sup;Park, Hye-Jun;Noh, Ji-Hye;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.147-156
    • /
    • 2011
  • Basic emotions such as happiness, sadness, anger, fear, and disgust have been widely used to investigate emotion-specific autonomic nervous system activity in many studies. On the contrary, surprise emotion, Suggested also as one of the basic emotions suggested by Ekman et al. (1983), has been least investigated. The purpose of this study was to provide a description of cardiovascular responses on surprise stimulus using electrocardiograph (ECG) and photoplethysmograph (PPG). ECG and PPG were recorded from 76 undergraduate students, as they were exposed to a visuo-acoustic surprise stimulus. Heart rate (HR), standard deviation of R-R interval (SD-RR), root mean square of successive R-R interval difference (RMSSD-RR), respiratory sinus arrhythmia (RSA), finger blood volume pulse amplitude (FBVPA), and finger pulse transit time (FPTT) were calculated before and after the stimulus presentation. Results show significant increase in HR, SD-RR, and RMSSD-RR, decreased FBVPA, and shortened FPTT. Evidence suggests that surprise emotion can be characterized by vasoconstriction and accelerated heart rate, sympathetic activation, and increased heart rate variability, parasympathetic activation. These results can be useful in developing an emotion theory, or profiling surprise-specific physiological responses, as well as establishing the basis for emotion recognition system in human-computer interaction.

  • PDF

Comparative Analysis of Coding Performance of Several ECG Compression Methods (ECG 압축 방법들의 코딩 성능 비교 분석)

  • Jang, Seung-Jin;Song, Sang-Ha;Yun, Yeong-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.137-138
    • /
    • 2008
  • 수많은 방식의 ECG 압축 코딩 알고리즘이 개발되어왔고 현재도 개발 중이지만 각자의 알고리즘의 성능에 유리한 특정 데이터만을 분석하고 압축율이 다름으로 인해 다른 알고리즘과의 성능 비교를 객관화하고 있지 못하였다. 본 연구에서는 기존의 MIT-BIH에서 제공하는 ECG 신호와 달리 시뮬레이션된 ECG 신호를 기반으로 각각의 알고리즘에 대한 성능비교를 하여 ECG신호의 특성에 따른 코딩 알고리즘의 압축율 및 평균 오차 에러의 정도를 분석비교하였다. 비교 대상 알고리즘으로는 상용화되어 널리 사용되는 Delta 코팅 방식의 문턱치를 갖는 Discrete Pulse Code Modulation과 Discrete Cosine Transform, Lifting Wavelet Transform과 Wavelet 기반 Linear Prediction 4가지 알고리즘을 대상으로 분석하였다. Compression Ratio (CR)을 2,4로 고정하고 Percentage of Root-mean-square difference (PDR)를 분석 한 결과, EMG 잡음의 진폭변 화에는 0.1mV이하의 경우 OCT, Wavelet Lifiting Transform이 낮은 PDR을 보였고, 01.mV이상의 경우 Wavelet based Linear Prediction (WLP)이 낮은 PDR을 보였다. Heart Rate의 간격에 변화를 주어 불규칙성이 있는 경우 WLP가 가장 안좋은 PDR 결과를 보였으며, DCT가 가장 낮고 안정된 PDR 결과를 보였다. DPCM은 노이즈와 진폭간격의 변화에 상관없이 압축율에 의해 크게 PDR 성능 결과가 변화함을 나타내었다.

  • PDF

The Effects of Hand Massage in Patients Who Underwent Transradial Percutaneous Coronary Intervention (요골동맥을 통한 경피적 관상동맥 중재술 환자의 손마사지 효과)

  • Shin, Eun Sil;Kim, Myung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.4
    • /
    • pp.465-474
    • /
    • 2018
  • Purpose: This study aimed to determine the effect of hand massage in patients who underwent transradial percutaneous coronary intervention. Methods: This was a quasi-experimental study with a nonequivalent control group and non-synchronized design. The study included 30 patients in the experimental group and 30 in the control group. Hand massage was performed 2 times for 5 minutes each in the experimental group and the control group only received usual nursing interventions. Pain, level of discomfort, and vital signs were defined as key outcome measures, and the data were analyzed using the chi-square test, an independent t-test, Mann-Whitney U test, repeated-measures analysis of variance, and Friedman test. Results: Significant differences were observed between the 2 groups in the pain score (F=7.91, p=.003), discomfort score (F=18.15, p<.001), pulse (F=12.92, p<.001), and respiration rate (${\times}^2=19.35$, p<.001). Conclusion: Hand massage can be a helpful nursing intervention for transradial percutaneous coronary intervention by reducing pain and discomfort to a considerable degree.

An Experimental Study of the Bioelectrical Signals and Subjective Response in Changing from Unpleasant to Pleasant Temperatures in a Learning Environment (학습환경에서 불쾌적온도에서 쾌적온도로의 변화시 생체신호 및 주관적 반응에 대한 실험적 연구)

  • Im, Gwanghyun;Kim, Jinhyun;Park, Chasik;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.596-602
    • /
    • 2015
  • In this study, experiments using bioelectronic signals and questionnaire surveys were carried out in learning conditions when temperatures changed from low- and high-uncomfortable to comfortable. As a result, the stress factor Photoplethysmography (PPG) decreased, while the Root Mean Square of Standard Deviation (RMSSD) of PPG increased when the indoor temperature was changed from low- or high-uncomfortable to comfortable. Additionally, the absolute power of the ${\alpha}$-wave in the brain increased. According to the analysis of the association between the questionnaire and bioelectronic signals, the standard deviation of the stress factor as measured by pulse was closely related to the result of the thermal sensation questionnaire. In addition, it was found that the concentration on studying improved under comfortable temperatures when compared to uncomfortable temperatures.