• Title/Summary/Keyword: Square patch

Search Result 113, Processing Time 0.02 seconds

Transmission Noise Seduction Performance of Smart Panels using Piezoelectric Shunt Damping (압전감쇠를 이용한 압전지능패널의 전달 소음저감 성능)

  • 이중근
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

  • PDF

Effects of Alcohol on Psychomotor Performance and Subjective Assessments In Normal Adults with Variation of Acetaldehyde Dehydrogenase I (정상성인에서 ALDH-I의 변이가 알콜의 정신운동성 수행과 주관적 평가에 미치는 영향)

  • Yoon, Bo Hyun;Yoon, Jin Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.222-239
    • /
    • 1996
  • The purpose of this study was to evaluate the effects of alcohol on the psychomotor performance and subjective assessment in healthy Korean adults with acetaldehyde dehydrogenase I(ALDH-I) isozyme variance. A total of 20 male subjects, half with active ALDH-I and the other half with inactive ALDH-I, were selected through both a self-reporting questionnaire examining alcohol sensitivity and the Higuchi's ethanol patch test detecting ALDH-I deficiency. In a doule-blind, placebo-controlled cross-over design, each subject consumed four doses of alcohol(0.25, 0.5, 0.75, 1.0g/kg) and placebo on five separate occasions at weekly intervals, Treatment order was fully balanced using a $5{\times}5$ Latin square, Psychomotor performance tests[coritical flicker fusion threshold(CFF) and choice reaction time(CRT)] and self-estimate questionnaires were conducted at baseline and at time points of 20, 40, 60, 90, 120, 150, 180 minutes after consuming the test drug for 20 minutes, Blood alcohol concentrations(BACs) using breath analyzer were measured at baseline and at time points of 10, 20, 30, 40, 50, 60, 75, 90, 105, 120, 150, 180 minutes after drinking, The BACs and the mean changes in the psychomotor performances and subjective assessments from pre-alcohol baseline, were compared between the two groups. The findings were summarized as follows : 1) BACs were tended to be higher in the inactive group than the active in all of the four alcohol doses. However significant group differences were only after the 0.5g/kg dose of alcohol. 2) The inactive group showed significant impairment in CFFT at most time points alter 0.75 and 1.0g/kg doses of alcohol. 3) In CRT, total reaction time(TRT) significantly prolonged in the inactive group than the active group at 20 minutes after 0.25 and 1.0g/kg doses of alcohol and at 40, 60, 90 minutes alter 0.75g/kg dose of alcohol. In the inactive group, recognition time component significantly increased at 20, 60, 90 minutes after 1.0g/kg dose of alcohol, while movement time component significantly increased at 40, 60 minutes after 0.75g/kg dose of alcohol. 4) Subjective evaluation of the effect of alcohol revealed that physical and mental conditions as well as a self-estimate of the effects of alcohol on performance were significantly worse in the inactive group than the active at some time points alter all of the lour alcohol doses, wihch were more pronounced after 0.75 and 1.0g/kg doses of alcohol. 5) Most of the group differences mentioned above, still remained statistically significant after BAC was entered as a covariate, These findings demonstrated that the alcohol sensitivity is higher in individuals with inactive ALDH-I than those with active ALDH-I both on the subjective assessments and the objective psychomotor performances. Furthermore, these results suggest thai the alcohol sensitivity may be determined by acetaldehyde concentration rather than BAC per se. In future studies, after more accurate genotyping for ALDH-I, the relationships between BAC, acetaldehyde concentration and alcohol sensitivities should be clearly defined.

  • PDF

Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina (정상 망막과 변성 망막을 위한 전기자극 파라미터)

  • Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium launched for developing retinal prosthesis. One of the prerequisites for the success of retinal prosthesis is the optimization of the electrical stimuli applied through the prosthesis. Since electrical characteristics of degenerate retina are expected to differ from those of normal retina, we performed voltage stimulation experiment both in normal and degenerate retina to provide a guideline for the optimization of electrical stimulation for the upcoming prosthesis. After isolation of retina, retinal patch was attached with the ganglion cell side facing the surface of microelectrode arrays (MEA). $8{\times}8$ grid layout MEA (electrode diameter: $30{\mu}m$, electrode spacing: $200{\mu}m$, and impedance: $50k{\Omega}$ at 1 kHz) was used to record in-vitro retinal ganglion cell activity. Mono-polar electrical stimulation was applied through one of the 60 MEA channel, and the remaining channels were used for recording. The electrical stimulus was a constant voltage, charge-balanced biphasic, anodic-first square wave pulse without interphase delay, and 50 trains of pulse was applied with a period of 2 sec. Different electrical stimuli were applied. First, pulse amplitude was varied (voltage: $0.5{\sim}3.0V$). Second, pulse duration was varied $(100{\sim}1,200{\mu}s)$. Evoked responses were analyzed by PSTH from averaged data with 50 trials. Charge density was calculated with Ohm's and Coulomb's law. In normal retina, by varying the pulse amplitude from 0.5 to 3V with fixed duration of $500{\mu}s$, the threshold level for reliable ganglion cell response was found at 1.5V. The calculated threshold of charge density was $2.123mC/cm^2$. By varying the pulse duration from 100 to $1,200{\mu}s$ with fixed amplitude of 2V, the threshold level was found at $300{\mu}s$. The calculated threhold of charge density was $1.698mC/cm^2$. Even after the block of ON-pathway with L-(1)-2-amino-4-phosphonobutyric acid (APB), electrical stimulus evoked ganglion cell activities. In this APB-induced degenerate retina, by varying the pulse duration from 100 to $1200{\mu}s$ with fixed voltage of 2 V, the threshold level was found at $300{\mu}s$, which is the same with normal retina. More experiment with APB-induced degenerate retina is needed to make a clear comparison of threshold of charge density between normal and degenerate retina.

  • PDF