• Title/Summary/Keyword: Spray pattern

Search Result 215, Processing Time 0.024 seconds

Effects of irradiation periods on the Lettuce Growth (광원 조사기간이 상추생육에 미치는 영향)

  • Kim, Dong-Eok;Kim, Bong-Soo;Kim, Hyun-Bae;Yoon, Yong-Cheol;Kim, Chi-Ho;Kim, Hyeon-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.4
    • /
    • pp.459-466
    • /
    • 2012
  • The objective of this study is to observe growth pattern of grand rapids(lettuce) according to different dexperimental conditions for minimizing its growth period such as composition of nutrient, irradiation time of light source and cultivation mode. The culture of water spray type using seeds of grand rapids was performed during growth period of total 50 days. Experimental conditions consist of five compositions of nutrient (PW 0.5 mS/cm, PW 1.0 mS/cm, PY 0.5 mS/cm, PY 1.0 mS/cm, PW 2.0 mS/cm) and three irradiation times of light source (12h(on) / 12h(off), 18h(on) / 06h(off), 24h(on) / 00h(off)). Illumination was adjusted to ratio of 7:1:1 of red, blue and white color, respectively. Indoor environmental condition for cultivating grand rapids is as follows: temperature (19-$22^{\circ}C$), relative humidity (60-70%) and carbon dioxide (1,000-1,200 ppm). The data were obtained from five iteration tests. The maximum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PY 1 mS/cm for 1st week of cultivation period, 24 hr(on) / 00 hr(off) and PY 1mS/cm for 2nd week of cultivation period, and 24 hr(on) / 00hr(off) and PW 1 mS/cm for 3rd week of cultivation period, respectively. On the contrary, the minimum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PW 0.5 mS/cm for 1st week of cultivation period, 12 hr(on) / 12 hr(off) and PW 0.5 mS/cm for 2nd week of cultivation period, and 12 hr(on) / 12 hr(off) and PY 0.5 mS/cm for 3rd week of cultivation period, respectively. Based on the results obtained from this study, it is concluded that the growth level of grand rapids varied with different irradiation time of light source and composition ratio of nutrient according to cultivation period.

Effects of Tree-spray of Calcium Agent, Coating Agent, GA4+7 + BA and Paper Bagging on Russet Prevention and Quality of 'Gamhong' Apple Fruits (칼슘제, 피막제, GA4+7 + BA의 수체살포 및 봉지씌우기에 의한 '감홍' 사과의 동녹 방지와 과실품질)

  • Moon, Young-Ji;Nam, Ki-Woong;Kang, In-Kyu;Moon, Byung-Woo
    • Horticultural Science & Technology
    • /
    • v.34 no.4
    • /
    • pp.528-536
    • /
    • 2016
  • This study was conducted to examine the effect of 0.4% of $CaCl_2$, $2H_2O$, $1mg{\cdot}L^{-1}$ of Calmodulin (CaM)-SH, 250-folds of coating agent (WE-36), 1,000-folds of $GA_{4+7}+BA$ and 3 types of paper bagging treatments on russet incidence and fruit quality attributes of 'Gamhong' apple. The pattern of russet occurrence was slightly different for 4 years (from 2012 to 2015) in 'Gamhong' apple. The russet occurrence was lowest in $GA_{4+7}+BA$ treatment at 20 days after full bloom (DAFB), compared with other treatments. The $GA_{4+7}+BA$ treatment increased fruit weight at 20 DAFB, while the other fruit quality attributes were not influenced. The russet occurrence was lower not only in a single bag application than in untreated ones but also in yellow bagging and discolored bagging applications than in a white bagging application. The russet occurrence in a bagging application was lower at 20 DAFB than at 30 and 40 DAFB, while fruit quality attributes were not affected by bagging applications. The russet incidence was lower in $GA_{4+7}+BA$ twice treatments at 20 and 30 DAFB, and calcium coated bag at 30 DAFB after $GA_{4+7}+BA$ treatment at 20 DAFB than in untreated fruit. The rate of russet incidence was lowest at equator region in $GA_{4+7}+BA$ treatment, compared with the other fruit regions. Overall, the results suggest that one and/or two applications of $GA_{4+7}+BA$ (1,000-folds) treatment at 20 DAFB should reduce the risk of russet incidence in 'Gamhong' fruit.

MICROTENSILE BONDING OF RESIN FIBER REINFORCED POST TO RADICULAR DENTIN USING RESIN CEMENT (레진 시멘트를 이용한 레진 파이버 강화 레진포스트의 치근 상아질에 대한 미세인장결합강도)

  • Kim, Jin-Woo;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.80-88
    • /
    • 2003
  • Object The purpose of this study were to evaluate the microtensile bond strength of resin fiber reinforced post to radicular dentin using resin cement according to various dentin surface treatment and to observe the inter face between post and root dentin under SEM Material and Method A total 16 extracted human single rooted teeth were used. A lingual access was made using a #245 carbide bur in a high-speed handpiece with copious air water spray. The post space was mechanically enlarged using H-file(up to #60) and Gates Glidden bures(#3). This was followed by refining of the canal space using the calbrating drill set provided in ER Dentinpost(GEBR, BRASSELER GmbH&Co. KG). The 16 teeth were randomly distributed into 4 group of 4 teeth. Group 1 teeth had their post space prepared using 10% phosphoric acid as root canal surface treatment agent during 20s. The canal was then rinsed with saline and dried with paper point. Group 2 teeth had their post space prepared using 3% NaOCl as root canal surface treatment agent during 30min. The canal was then rinsed with saline and dried with paper point. Group 3 teeth had their post space prepared using 17% EDTA as root canal surface treatment agent during 1min. The canal was then rinsed with saline and dried with paper point. Group 4 teeth had their post space prepared using 17% EDTA as root canal surface treatment agent during 1min. After rinsing with saline, the canal was rinced 10m1 of 3% NaOCl for 30min. After drying with paper point, the post(ER Dentinpost, GEBR, BRASSELER GmbH&Co. KG) was placed in the treated canals using resin cement. Once the canal was filled with resin cement(Super bond C&B sunmedical co. Ltd.), a lentulo was inserted to the depth of the canal to ensure proper coating of the root canal wall. After 24 hours, acrylic resin blocks($10{\cdot}10{\cdot}50mm$) were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strengths for each stick was measured with Microtensile Tester. Failure pattern of the specimen at the interface between post and dentin were observed under SEM. Results 1. Tensile bond strengths(meen{\pm}SD$) ) were expressed with ascending order as follows group 4, $12.52{\pm}6.60$ ; group 1, $7.63{\pm}5.83$ ; group 2, $4.13{\pm}2.31$ ; group 3, $3.31{\pm}1.44$. 2. Tensile bond strengths of Group 4 treated with 17% EDTA +3%NaOCl were significant higher than those of group 1, 2 and 3 (p<0.05). 3. Tensile bond strengths of Group 1 treated with 10% phosphoric acid were significant higher than those of group 2 (p<0.05). Tensile bond strengths of Group 4 treated with 17% EDTA +3% NaOCl was significant higher than those of other groups.

Residual Pattern of Pesticide, Chlorfluazuron in Perilla Leaves Under Plastic House (들깻잎 재배 중 chlorfluazuron의 잔류량 변화 및 잔류분석법 시험)

  • Lee, Min-Ho;Kim, Seok-Ho;Park, Young-Guin;Jo, Gyeong-Yeon;Shin, Byung-Gon;Kim, Jong-Han;Kwon, Chan-Hyeok;Sohn, Jae-Keun;Kim, Jang-Eok
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.2
    • /
    • pp.106-116
    • /
    • 2007
  • Pesticide, chlorfluazuron was subjected to determine the safety of terminal residues at the harvesting date of perilla leaves cultivated in plastic house. After the pesticide applied on a foliar spray in 2005 and 2006, leaf persistence of its residue was analysed for 10 days before leaf harvest. The degradation rate of chlorfluazuron in the leaf was 32.3 %(standard application), 43.6 %(double application) and 78.0 %(standard), 80.4 %(double) at second and tenth day, respectively, under analysis of GC/ECD in 2005. The degradation rate of chlorfluazuron in the leaf was 33.1 %(GC/ECD analyze), 34.0 %(HPLC/UVD analyze) and 77.9 %(GC/ECD), 78.4 %(HPLC/UVD) at second and tenth day, respectively, under the standard level of pesticide in 2006. The biological half-life of the chlorfluazuron residue was estimated by the regression equation calculated from daily dissipation of pesticide in the perilla leaves. The longest half-life of the chlorfluazuron residue in perilla leaves was 5.5 days. The maximum residual limit(MRL) for chlorfluazuron based on the longest half-life was estimated 2.0ppm at harvesting day, 2.5ppm at second day and 7.1ppm at tenth day before leaf harvesting of perilla.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF