• Title/Summary/Keyword: Spray height

Search Result 142, Processing Time 0.021 seconds

An Experimental Study on Nozzle Spray Characteristics for the Design of Heat Exchangers of a Nano-Silver HVAC System (은나노 공조시스템의 열교환기 설계를 위한 노즐의 분무특성 실험)

  • Heo, Ju-Yeong;Kang, Byung-Ha
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.534-537
    • /
    • 2008
  • Growing attention has been given to sterilizing and antibacterial effects of nano-silver, recently. Nano-silver solution can be applied to the heat exchanger in an air conditioner to prevent bad smell or bacteria. The present study is directed at the nozzle spray characteristics over a heat exchanger. This problem is of particular interest in the design of a nano-silver HVAC system. The effects of nozzle position and flow rate on the spray area over a horizontal surface have been investigated for various nozzles. The results obtained indicate that spray area is increased as the height of spray position is increased or mass flow rate is increased. The wetted area over a practical heat exchanger is also studied at a given nozzle height. It is found that the wetted area is gradually increased with an increase in the flow rate. However, the effect of flow rate on the wetted area is a little affected by flow rate in the range of too much flow rate. It is also found that the wetted area is decreased as the inclination angle of a heat exchanger is increased.

  • PDF

Behavior of a Diesel Spray Impinged on a Wall (벽면에 충돌하는 디젤분무의 거동)

  • Cho, I.Y.;Oh, J.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.1-6
    • /
    • 1997
  • In the case of analyzing the combustion phenomena in a small high speed DI diesel engine, one demands the experimental results of the impinging spray on the wall as a basic characteristics. In the experiments presented here, diesel fuel oil was injected into a high pressure chamber in which compressed air at room temperature was charged. The single spray was impinged on a flat wall. The growth of the spray was photographed with transmitted light or scattered light. The effect of the spray axis angle to the wall on the impinging spray was revealed. Finally, the experimental results was presented, that is, the radius and height of the impinging spray was influenced by above mentioned variable.

  • PDF

Effect of Foliar Spray and Soil Drench of Triazole Chemicals on Growth and Flowering in Zinnia elegans (Triazole계 화합물의 엽면살포 및 토양관주 처리가 백일홍의 생장 및 개화에 미치는 영향)

  • Lee, Seung Woo;Ahn, Sung Eun;Kim, Young Chai
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.568-573
    • /
    • 2001
  • The effects of foliar spray and soil drench application of triazole chemicals (diniconazole, myclobutanil, difenoconazole, tebuconazole, bitertanol, hexaconazole) on growth and flowering control in zinnia were investigated. For foliar spray application of tebuconazole, diniconazole and bitertanol on 'Dream Land Rose', plant height was decreased but tebuconazole gave the best result for dwarfing. Diameter, fresh and dry weights of flower were markably decreased at high concentration of tebuconazole. However, days to flowering was not affected by chemicals tested. For 'Dream Land Scarlet', plant height was decreased with all chemical treatments. Tebuconazole severely decreased plant height, in particulas. Diniconazole hastened flowering. For soil drench of 'Dream Land Rose', plant height was decreased by diniconazole and mycrobutanil, but diniconazole was more effective for plant height decrease. Flowering was hastened by diniconazole in both 'Dream Land Rose' and 'Dream Land Scarlet'. Plant height of 'Dream Land Scarlet' was decreased by all chemicals tested. Flowering was not occurred at $300mg{\cdot}L^{-1}$ myclobutanil with severe suppression of stem growth.

  • PDF

Design Factors of Boom Sprayer(I) - Spray Patterns of Nozzles - (붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(I) -노즐의 분무유형-)

  • 정창주;김학진;조성인;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.217-225
    • /
    • 1995
  • This study was conducted to find design factors of spraying device of the boom sprayer for low volume application. Four types of nozzles(standard flat nozzle, drift guard nozzle, even flat nozzle, and hollow cone nozzle) were used for the spray characteristic experiment. Spray patterns of the nozzles were distinguished by the nozzle type, spray distance, and spray direction. The flow rate was proportional to the square root of spray pressure in all nozzles. Increased nozzle height improved spray distribution at reduced pressures and/or increased spacing. Distribution tended to improve as pressure increased within the range of pressures used for fan nozzles.

  • PDF

Effect of Seed Soaking and Foliar Spray of Plant Growth Retardants on Growth and Flowering in Zinnia elegans (백일홍의 생장 및 개화에 미치는 식물생장억제제의 침종 및 경엽살포의 영향)

  • Lee, Seung Woo;Ahn, Sung Eun;Kim, Young Chai
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.574-578
    • /
    • 2001
  • The effects of seed soaking (8 and 24 hours) and foliar spray of plant growth retardants (daminozide, chlormequat and uniconazole) on growth control in zinnia were investigated. For seed soaking of 'Dream Land Rose', the changes in plant height was not affected by seed soaking time (8 and 24 hours), while it was severely suppressed by high concentration of chemicals tested. An application of $125mg{\cdot}L^{-1}$ uniconazole was most effective for plant height suppression. Flowering was promoted by all treatments of chemicals. However, for 'Dream Land Scarlet', plant height control at 24 hours seed soaking showed more effective than 8 hours, and all treatments of chemicals decreased plant height. Uniconazole gave the best result for plant height control. Flowering tended to be hastened by the treatment of chemicals. For foliar spray, plant height was remarkably decreased at high concentration of uniconazole. Flowering was promoted by chlormequat and uniconazole in both 'Dream Land Rose' and 'Dream Land Scarlet'. Also, daminozide decreased number of petals.

  • PDF

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

A Case Study on the Measurement Volatile Organic Compounds and Total Hydrocarbon Concentrations in Block Paint-Shops at a Shipyard (조선소 블록 도장시설에서의 휘발성 유기화합물과 총 탄화수소 농도측정 사례)

  • Yang, Sung-Bong;Yu, Mee Seon;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1177-1189
    • /
    • 2016
  • In order to prepare the information needed to construct a reduction system for volatile organic compounds (VOCs) exhausted from ship-block paint-booths in a giant shipyard, VOCs in paint-shop airs were analyzed and compared to the components in paint thinners. Aromatic hydrocarbons containing eight and nine carbon atoms are known to be major VOC compounds found in shipyard paint-shops. The total hydrocarbon (THC(C7)) concentrations calibrated using toluene gas, were measured in block paint-shops with two photo-ionization detector (PID) meters, and the resulting THC(C7) data were converted to THC(C1) concentrations according to the Standard Methods for the Measurements of Air Pollution in South Korea. THC(C1) concentrations near the spray site ranged from 10 to 2,000 ppm, but they were less than 400 ppm near the walls of the paint-booth. The measurements of THC concentrations, based on the height of the monitoring sites, were related to the height of the target to which the spray paints were applied. The maximum concentrations occurred at almost the same height as the spray targets. When painted blocks had been dried-by warming with no spraying, the THC concentrations were 80~100 ppm.

The Effect of Ambient Gas Density on the Development of Impinging Diesel Spray (분무실 밀도 변화가 충돌 디젤분무 특성에 미치는 영향)

  • Kim, J.H.;Lee, B.S.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.4 no.2
    • /
    • pp.40-46
    • /
    • 1999
  • Experimental investigation of unsteady impinging diesel spray on the flat plate have been carried out using high speed camera and Malvern system. The density ratios of ambient gas to diesel fuel were varied using $N_2$ and Ar gas in the case of 14.9, 21.2, 28.4, 35.1, 40.4, and 50.1. With the increase of gas density ratio, the radial penetration is decreased due to the resistance of the ambient gas. With the increase of the gas density ratio and the distance between nozzle tip and flat plate, the height of spray is increased due to the entrance and circulation. With the increase of gas density ratio, SMD is decreased on the nearby position at the center of flat plate, but SMD is increased on the far position. As the distance between nozzle tip and flat plate is increased, SMD is always decreased.

  • PDF

Assessment of Dispersion Coefficients and Downward Positions of Water Spray for Small-Scale Release of Chlorine Gas

  • Jang, Seo-Il;Kim, Youngran;Yu, Wooyun;Shin, Dongil;Park, Kyoshik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • To assess downward positions of water spray for the small-scale release of chlorine gas, dispersion coefficients for the Gaussian dispersion model were validated at the small-scale release experiment. And the downwind distances of water spray were assessed with the simulated results. As results, the Gaussian plume model using the Briggs' dispersion coefficient well estimated the dispersed characteristics for small-scale release of chlorine gas. The best adequate downwind position of water spray is the position of the maximum concentration of chlorine at the ground level. And the adequate vertical and horizontal dimensions of water spray consider the maximum width and height of cloud.

Recent Developments in Agricultural Sprays : Review

  • No, S. Y.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.44-54
    • /
    • 2002
  • A brief review of current status in the field of agricultural spray and future research challenges are presented. Researches on the pesticides sprays, pollen sprays, postharvest sprays, and biological control agent sprays among the various applications of agricultural spray were selected and reviewed. In the agrochemical sprays, the techniques to increase the deposition such as electrospray and reduce the drift such as introductions of drift retardants and of mechanical means are reviewed. The introduction of mechanical means includes low drift, air-assisted, air inclusion, shield or shroud assisted and pulse flow nozzles. For flat fan nozzles, the data of breakup length and thickness of liquid sheet are essential to understand the atomization processes and develop the transport model to target In the air-assisted spray technology to reduce drift, further works on the effect of application height on drift and air assistance on droplet size should be followed. In addition, methods for quantifying the included air in the air inclusion techniques are required. The atomization characteristics of biopesticides spray are not being elucidated and the formulations of biopesticides should be taken into account the spray characteristics of existing nozzle and sprayer. A few researches on the droplet size of fallout can be found in the literature. A combined technology with electrostatic method into one of method for the reduction of drift may be an effective strategy for increasing deposition and reducing drift. Only an integrated approach involving all stakeholders such as engineers, chemists, and biologists, etc. can result in improved application of agricultural spray.

  • PDF