• Title/Summary/Keyword: Spray Test

Search Result 859, Processing Time 0.03 seconds

Research and Development Trend of Gas Turbine Combustor in Korea (한국의 가스터빈엔진 연소기 연구개발 동향)

  • Choi, Seongman
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.287-289
    • /
    • 2012
  • The research and development history of the gas turbine combustor in Korea is introduced briefly. It is very important to understand the fuel spray, mixing phenomena in achieving combustion performance. In this paper, two kinds of fuel injection system such as duplex fuel injector and rotary spray system are introduced in developing gas turbine combustor in Korea. The extensive experimental research of fuel spray, ignition, performance and endurance rig test makes gas turbine combustor successfully in Korea.

  • PDF

A Study on Diesel Spray Combustion Modeling by Eulerian and Lagrangian Conditional Moment Closure Models (Eulerian 및 Lagrangian CMC 모델을 사용한 디젤분무연소 모델링에 관한 연구)

  • Kim, Woo Tae;Cho, Hyun Su;Huh, Kang Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.195-198
    • /
    • 2012
  • Numerical simulation is performed to evaluate the conditional moment closure (CMC) models for spray development, ignition, and turbulent combustion for the Engine Combustion Network (ECN) test cases. The CMC model is implemented in the open source code, OpenFOAM, to provide conditional flame structures through the solution of Eulerian as well as Lagrangian conditional transport equations. In spite of more accurate treatment of the convective term, Eulerian CMC provides similar ignition delays and lift-off lengths with Lagrangian CMC.

  • PDF

STUDY ON THE CURVE DEPENDENT WHEEL FLANGE LUBRICATOR WITH CREASE SPRAY TYPE (곡선감지형 그리스 분사식 후렌지 도유기에 관한 연구)

  • 이주호;노양환;양방섭
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.188-192
    • /
    • 2002
  • In this study, Curve dependent wheel flange lubricator with grease spray type is introduced and checked and estimated a point of view reducing wheel flange wear and noise in the curve. Advantage of curve dependent wheel flange lubricators with grease spray type is found on the basis of the result of field test applied to KNR No. 1 Line(reconstruction car).

  • PDF

A study on the velocity distribution measurement for the fine water mist spray by using LSP method (LSP법에 의한 미세 물 분무 입자 고도분포계측에 관한 연구)

  • 이동호
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.24-28
    • /
    • 1996
  • The speckle photography technique is one of the novelest velocity measurement methods. This study examines the possibility that this technique will become practically applicable. In this study, LSP is applied to the fine water mist spray. Moreover, a He-Ne gas laser is employed as the light source in order to enhance the validity of this technique. It becomes clear that this technique using a He-Ne gas laser can obtain a whole instantaneous two-dimensional velocity distribution and also apply to test the performance of fine water spray.

  • PDF

Adhesion of Plasma Spray Coated Hydroxyapatite Film on the Two-Step Anodized Dental Implant

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.126-126
    • /
    • 2012
  • In this study, adhesion of plasma spray coated hydroxyapatite film on the two-step anodized dental implant was investigated. The plasma spray was carried out on the dental implant after two step anodization. The adhesion of coated HA film was investigated by FE-SEM after fatigue test. In the case of two-step anodized implant showed a good adhesion between implant and coated film.

  • PDF

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

Spray Charaeteristics and Exhaust Emission Tests far a Diesel Engine Using Emulsified Fuels (에멀젼 연료를 이용한 디젤엔진의 분무 및 배기특성 연구)

  • 서희준;오승묵;허환일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.60-68
    • /
    • 2002
  • Experiments have been conducted to investigate the effects of emulsified fuels on the spray characteristics and exhaust emissions in a diesel engine. Four different fuels were examined : diesel, emulsified fuels with water contents which were varied with 13, 15, and l7wt%. Characteristics of fuel spray were measured by an optical method, PLLIF(planar liquid laser induced fluorescence). Compared to diesel fuel, emulsified fuels which had relatively high kinematic viscosity showed smaller spray angle and longer spray tip penetration. The qualitative droplet distributions of emulsified fuels showed worse atomization process than that of diesel fuel. As the water contents were increased, PM and NOx could be reduced simultaneously. It was specially noted that the emulsified fuel with l7wt% water content was found to be the best in reducing rates, NOx 30% and PM 40%.

Evaluation of Unavailability of the Containment Spray System by use of a Cause-Consequence Chart

  • Park, Gwi-Tae;Chun, Hee-Young;Lee, Chang-Kun
    • Nuclear Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.195-202
    • /
    • 1979
  • In this paper, a cause-consequence chart is applied to evaluate the probability that the containment spray system in a nuclear power plant may not be woring properly, given a demand for spryaing at loss of coolant accident (LOCA). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of this system, in case the test policy of the system is taken into account, i.e., average probability that the containment spray cannot be established, and average probability that the containment spray is established : spray stops before the required operating time is over.

  • PDF

Photocatalytic Properties of $TiO_2$ Coatings Prepared by Cold Spray Process

  • Han, Jong-Hyuck;Lee, Soo-Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.183-184
    • /
    • 2005
  • Four different coatings deposited using cold spray process were studied with two different powder agglomerating techniques (spray d교 and evaporated powder) and using $TiO_2$ nano-sized powders with and without a 10wt% addition of ZnO. Characterization was performed by SEM, XRD and roughness test. Also the photocatalytic effect of the coatings was evaluated. Although the change of powder preparation techniques and the addition of ZnO into $TiO_2$ did not show appreciable variations in the surface morphology and Anatase phase transformation, it did show influence on the surface roughness of the coating, the highest roughness being found in the coatings made by spray powder prepared method. Regarding the photocatalytic effect it was observed that the using the spray dry coating and the addition of ZnO are promoter of purification at higher rates.

  • PDF

Fire Suppression Experiment for Road Tunnel Low Pressure Water Spray Systems (도로터널 저압 물분무설비 화재진압 실험)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.218-221
    • /
    • 2008
  • The real scale fire suppression test inside a road tunnel were carried out for water spray systems. The dimension of the tunnel is 7.5m in height and 11.6m in width. 3 different water spray nozzle systems with low operating pressure less than 3.5 bar were used in the experiment. Two types of fires were tested. One is a $1.4m^2$ heptane pool fire and the other is a 2000CC passenger car fire. From the experiment, the spray densities of tested systems were about $6.0\;l/min/m^2$ which is currunt domestic guideline. Although all the systems cannot extinguish the tested fires, it was found that they can reduce the tunnel temperature and have a capability to control and suppress the tested fire.

  • PDF