• 제목/요약/키워드: Spray Measurements

검색결과 187건 처리시간 0.024초

Fabrication and Evaluation of a Total Organic Carbon Analyzer Using Photocatalysis

  • Do Yeon Lee;Jeong Hee Shin;Jong-Hoo Paik
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.140-146
    • /
    • 2023
  • Water quality is crucial for human health and the environment. Accurate measurement of the quantity of organic carbon in water is essential for water quality evaluation, identification of water pollution sources, and appropriate implementation of water treatment measures. Total organic carbon (TOC) analysis is an important tool for this purpose. Although other methods, such as chemical oxygen demand (COD) and biochemical oxygen demand (BOD) are also used to measure organic carbon in water, they have limitations that make TOC analysis a more favorable option in certain situations. For example, COD requires the use of toxic chemicals, and BOD is time-consuming and can produce inconsistent and unreliable results. In contrast, TOC analysis is rapid and reliable, providing accurate measurements of organic carbon content in water. However, common methods for TOC analysis can be complex and energy-intensive because of the use of high-temperature heaters for liquid-to-gas phase transitions and the use of acid, which present safety risks. This study focuses on a TOC analysis method using TiO2 photocatalysis, which has several advantages over conventional TOC analysis methods, including its low cost and easy maintenance. For TiO2, rutile and anatase powders are mixed with an inorganic binder and spray-coated onto a glass fiber substrate. The TiO2 powder and inorganic binder solutions are adjusted to optimize the photocatalytic reaction performance. The TiO2 photocatalysis method is a simple and low-power approach to TOC analysis, making it a promising alternative to commonly used TOC analysis methods. This study aims to contribute to the development of more efficient and cost-effective approaches for water quality analysis and management by exploring the effectiveness and reliability of the developed equipment.

연성 플라스틱 기판위에 스프레이 코팅방법으로 제조한 유·무기 보호막의 특성 (Properties of Organic-Inorganic Protective Films on Flexible Plastic Substrates by Spray Coating Method)

  • 이상희;장호정
    • 마이크로전자및패키징학회지
    • /
    • 제24권4호
    • /
    • pp.79-84
    • /
    • 2017
  • 태양전지와 같은 광전소자의 특성 및 신뢰성 유지하기 위해서는 수분과 산소 등으로 부터 소자 내부가 보호되어야 한다. 본 연구는 여러 연성(flexible) 플라스틱 기판위에 유 무기 복합 보호막을 스프레이코팅 방법으로 형성하여 공정조건(노즐 위치, 박막 두께, 기판 구성)에 따른 소자의 보호특성을 연구하였다. 사용된 복합 보호막 재료로서 PVA (polyvinyl alcohol)와 SA(sodium alginate) 혼합 유기 물질(P.S)에 $Al_2O_3$($P.S+Al_2O_3$)과 $SiO_2$($P.S+SiO_2$) 나노 분말을 혼합하여 유 무기 복합 보호막 용액을 합성하였다. 플라스틱 기판 위에 코팅한 보호막의 두께가 $5{\mu}m$에서 91%의 투과율을 나타내었으며 $78{\mu}m$에서 $178{\mu}m$로 두께가 증가할 경우 광 투과율은 81.6%에서 73.6%으로 감소하였다. 또한 합성한 $P.S+Al_2O_3$ 복합재료를 사용하여 PEN(polyethylene naphthalate), PC(polycarbonate) 단일 플라스틱 기판과 Acrylate film과 PC 이중막(Acrylate film/PC double layer) 구조와 $Al_2O_3$ 무기박막과 PEN 이중막($Al_2O_3$ film/PEN double layer) 구조의 기판 위에 $P.S+Al_2O_3$ 용액을 사용하여 수분투과도(water vapor transmission rate, WVTR)와 표면형상 등을 측정하여 최적의 보호막 구조를 확인하였다. 즉, $Al_2O_3$ film/PEN 이중막 기판위에 형성한 보호막의 수분투과 값은 $0.004gm/m^2-day$로 가장 우수한 내 투습 특성을 나타내었다.

작은 분무입자(噴霧粒子)에 있어서 원형분무입자(原形噴霧粒子) 직경(直徑)과 살포(撒布)된 입자직경(粒子直徑)의 관계(關係) (Relationships between Airborne Droplet and Impression Diameters in Small Droplets)

  • 이상우
    • 농업과학연구
    • /
    • 제6권2호
    • /
    • pp.192-197
    • /
    • 1979
  • 분무철포립자(噴霧撤布粒子)의 연구(硏究)에 있어서 공기중(空氣中)에 표류하고 있는 분무립자(噴霧粒子)의 직경(直徑)을 직접(直接) 측정(測定)하기 어려우므로 입자(粒子)자국의 직경(直徑)과의 비(比)인 확산비(擴散比)(Spread factor)를 이용(利用)함이 일반적(一般的)이다. 물에 Geigy Red Herbicide 물감을 0.5%로부터 2%까지의 중량비(重量比)로 혼합하여 분무액(噴霧液)을 준비하고 균일(均一)한 크기의 입자발생장치(粒子發生裝置)로 발생(發生)한 공기중(空氣中)의 표류 입자(粒子)의 직경(直徑)을 측정(測定)하고 이들 입자(粒子)들을 바로 표본기지(標本期紙) 또는 Eucalypt 잎위에 받아서 입자(粒子)자국의 직경(直徑)들을 측정(測定)하여 입자(粒子)자국의 직경(直徑) 대(對) 공기중(空氣中)의 표류입자(粒子)의 직경(直徑)의 비(比)인 확산비(擴散比)를 구(求)한 결과(結果) 다음과 같은 결론(結論)을 얻었다. 공기중(空氣中)의 표류입자(粒子)의 직경(直徑)과 Kromekote 용지(用紙) 또는 Eucalypt 잎위에 살포(撒布)된 입자(粒子)자국직경(直徑)의 상관성(相關性)의 방정식(方程式)의 일반형(一般形)은 지수방정식(指數方程式)인 $Y=aX^b$로서 log-log 그라프용지(用紙) 상(上)에 직선관계식(直線關係式)으로 나타났다. 엷은 농도 용액의 확산비가 진한 농도 용액의 확산비 보다 일반적(一般的)으로 크게 나타났다. Eucalypt 잎 상(上)에서의 확산비는 용액이 잎속으로 침투하고 엽면(葉面)의 오목한 기공(氣孔)을 가진 표면(表面)으로 인(因)하여 Kromekote 용지(用紙) 상(上)의 확산비보다 상당히 작게 나타났다. Eucalypt 잎 상(上)에 낙하된 입자(粒子)의 평균(平均)두께 추정식(推定式)은 $Y=aX^b$로서 확산비의 상관식(相關式)과 같은 형(形)이었고 이 식(式)은 병충해방제(病蟲害防除) 최소직경(最小直徑)의 입자(粒子)를 기준(基準)할 때 이기준치(基準値)보다 큰 입자(粒子)를 살포(撒布)하는 경우에 있어서 입자(粒子)가 클수록 과잉살포결과를 초래하고 있음을 의미(意味)하고 있다.

  • PDF

EFFECTS OF THE ER,CR:YSGG LASER ON BONE BED PREPARATION WITH VARIOUS LASER TIPS

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Hong, Seong-Doo;Lee, Shin-Jae;Lee, Joo-Hee
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.255-260
    • /
    • 2008
  • STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 ${\mu}s$ pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm${\Phi}$), Group 2: paralleled - shaped zirconia tip (0.6 mm${\Phi}$), Group 3: tapered sapphire tip (0.4 mm${\Phi}$). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

술 전 분무한 10% lidocaine이 현미경 하의 후두 미세 수술 시 혈역학적 반응에 미치는 영향 (The Effects of Preoperative Sprayed 10% Lidocaine on the Hemodynamic Response during Suspension Microlaryngeal Surgery)

  • 이덕희;도현석
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.162-169
    • /
    • 2007
  • 현미경 하 후두 미세 수술에서 10% lidocaine 술 전 분무가 혈역학적으로 어떠한 영향을 미치는 지를 보기 위하여 대상 환자 50명을 각 25명씩 두 군으로 나누어 대조군과 10% lidocaine 분무군으로 하였다. 마취 유도 후 대조군에서는 근이완제 투여 후 3분 30초에 기관내 삽관을 시행하였으며, 연구군은 근이완제 투여 2분 후 인후두 점막과 기관내에 lidocaine 1.5 mg/kg을 분무하였고 다시 1분 30초 후에 기관내 삽관을 시행하였다. 수축기 및 이완기 혈압과 심박수를 마취 유도 전에 측정하여 기준치(T0)로 삼았으며 기관내 삽관 후 1분(T1), 3분(T2), 5분(T3), 현수 후두경 거치 후 1분(T4), 3분(T5), 5분(T6), 10분(T7)에 각각 측정하여 기록하였다. 동맥압과 심박수가 기관내 삽관후 3분까지 그리고 현수 후두경 거치 후 3분까지 대조군에 비하여 10% lidocaine 분무군에서 유의하게 낮음을 보아 기관내 삽관 전 10% lidocaine 분무는 기관내 삽관과 현수 후두경으로 인한 심혈관계 자극을 효과적으로 완화시킴을 알 수 있다.

  • PDF

환원된 그래핀 산화물을 보호 층으로 적용한 4H-SiC 표면 거칠기 향상 연구 (Improvement of 4H-SiC surface morphology using r-GO as a capping layer)

  • 성민제;김성준;김홍기;강민재;이남석;신훈규
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1226-1229
    • /
    • 2018
  • 본 연구에서는 이온주입 된 4H-탄화규소(SiC) 에피 층 위에 환원된 그래핀 산화물 (r-GO)을 보호 층으로 적용하여 고온 열처리 공정 중 발생하는 표면 거칠기 악화를 개선하였다. 실험에 사용 된 4H-SiC 에피 층은 $4^{\circ}$ off-axis n-형 4H-SiC 기판 위에 $10{\mu}m$ 두께로 성장되었다. $n^+$-형 4H-SiC 층을 제공하기 위해 $1.73{\times}10^{15}cm^{-2}$ 농도의 질소를 고온 고에너지 이온주입 공정으로 주입하였고, 보호 층으로 사용한 r-GO는 스프레이 코팅 방식으로 4H-SiC 층 위에 형성하였다. r-GO를 보호 층으로 적용 한 결과, 적용하지 않은 시료에 비해 고온 열처리 후 표면 거칠기 (RMS)가 10배 개선되었으며, 전기적 측정으로 추출한 누설 전류를 통해 표면 거칠기 개선으로 표면 상태가 완화되었음을 확인하였다.

섬유질 단열재의 열적 특성 및 내화성능 (Thermal Property and Fire Resistance of Cellulose Insulation)

  • 권영철;서성연;김성용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.203-212
    • /
    • 2005
  • 섬유질 단열재는 주로 폐신문지로 만드는 데, 내화성능을 위해 내화재로 처리된다. 내화재로 인해 연소가 되지 않을 뿐 아니라, 연기도 나지 않는다. 섬유질 단열재의 열저항은 유리섬유나 암면보다 더 뛰어나다. 섬유질 단열재는 폐지로 만들어지므로 폐기시에는 잘 부식되고, 내재에너지 또한 매우 작은 친환경 단열재이다. 국내 건축물에 섬유질 단열재를 광범위하게 이용하기 위해서는 국내 건축법규 상의 단열규정에 적합한지 여부를 판단할 수 있는 물리적 성능 테스트가 필요하다. 따라서 국내에서 생산되는 섬유질 단열재에 대한 열전도율 및 내화성능 실험을 ASTM C 518과 ASTM C 1485에 근거하여 실시하였다. 국내생산 섬유질 단열재는 동일밀도의 미국제품에 비해 열전도율이 약 5%정도 높게 나타났다. 이러한 결과는 폐지원지의 섬유질이 서로 다른데서 기인하는 것으로 판단된다. 습식분사방식과 공기충진방식 모두 온도가 $5.5^{\circ}C$ 상승할 때 마다 약 1.5%씩 열전도율이 높아지는 것으로 나타났다. 섬유질 단열재의 내화성능은 내화재의 함유량에 비례하여 일정하게 증가되는 것으로 나타났다. 높은 내화성능으로 인해 불에 약한 우레탄폼이나 스치로폼을 대체할 수 있다. 섬유질 단열재의 열전도율은 시편의 온도가 $4-43^{\circ}C$인 경우 $0.037-0.043W/m{\cdot}K$로 나타났다. 이는 국내 건축법규 상의 "나"등급에 해당하는 값이다. 내화재가 열전도율에 미치는 영향은 미미하였으며, 내화재가 전혀 들어있지 않은 경우가 가장 열전도율이 높게 나타났다. 섬유질 단열재의 단열성능은 유리섬유나 암면에 비해 뛰어나고, 스치로폼이나 우레탄폼에 비해 내화성능은 훨씬 뛰어나다. 따리서, 물리적인 성능을 고려한다면 위의 기존 단열재들을 대체할 수 있다. 섬유질 단열재는 스치로폼이나 우레탄폼에 비해 값도 싸므로 국내에서도 더욱 폭 넓게 사용하는 것이 추천된다.