• 제목/요약/키워드: Spray Control

검색결과 829건 처리시간 0.025초

Residue analysis of spinetoram and spinosad on paprika leaf using the modified QuEChERS pre-treatment methods

  • Kim, Young-Shin;Yang, Jun-Young;Jin, Na-Young;Yu, Yong-Man;Youn, Young-Nam;Lim, Chi-Hwan
    • 농업과학연구
    • /
    • 제44권4호
    • /
    • pp.487-494
    • /
    • 2017
  • Spinosad and spinetoram are widely used insecticides for the control of lepidopteran larvae, leaf miners, and thrips; however, they might also have low toxicity toward beneficial insects like bees. Because these pesticides are easily photolyzed by ultraviolet radiation, the QuEChERS method, with its simple pretreatment procedure, is often used for analyzing residues of spinosad and spinetoram. The present study performed a residue analysis using a modified QuEChERS method by pretreating with ammonium salt. The limit of detection (LOD) of the modified method was 0.05 mg/kg and the limit of quantification (LOQ) was 0.25 mg/kg. The coefficient of determination ($R^2$) for the calibration curve was 0.999. Also, we examined any change in the adhesion of spinosad and spinetoram on the plants depending on a spray volume. The adhesion was approximately 70% when the spray volume was increased from 60 L to 120 L per 10 a whereas the adhesion was approximately 37% when the spray volume was increased from 125 L to 250 L. This showed that the amount of adhesion decreased with the higher spray volume. The efficacy result of spinetoram was that over 90% of Frankliniella occidentalis was controlled with the application volume of 125 L per 10 a. Therefore, the result of this study indicates that control of insects is effective and sufficient with a spray volume of 125 L per 10 a in paprika cultivation facilities.

스마트 운영 모드를 활용한 농업용 방제 드론의 특성 분석에 관한 실험적 검증 (Experimental Verification of the Characteristic Analysis of the Aricultural Drone using Smart Operating Mode)

  • 이우람
    • 문화기술의 융합
    • /
    • 제9권6호
    • /
    • pp.1049-1055
    • /
    • 2023
  • 농업용 드론을 이용한 방제 작업의 경우 그 경제적 효율성으로 인해 활용도가 증가하고 있으나, 작업자의 숙련도에 따라 효과의 차이가 발생한다. 이에 본 연구에서는 스마트 운영 모드를 적용하여, 수동 비행 모드에서 제어의 단점을 보완하고 이에 대한 수치적 모델을 제안하고, 선행 연구와 비교 검증을 통해 실험적 검증을 수행하였다. 그 결과 농업용 방제 드론들의 분사 시간 및 방제면적을 도출하였고, 수치적 모델과 유사성이 높은 방제용 드론을 선정하여 실험적으로 검증하였다. 이를 통해 수동 비행 모드보다 스마트 운영 모드 적용 시 살포 면적 및 작업(살포 균일도 및 작업 효율)이 상대적으로 효과적인 것을 확인하였다.

분무탑식 스크러버에서 이류체 정전분무에 의한 집진효율의 향상 (Collection Efficiency Enhancement of Spray Tower Scrubber by Introducing Electrospray with Two-flow Nozzle)

  • 황유성;김종호;김종현
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.339-345
    • /
    • 2010
  • There have been a number of efforts to satisfy national emission regulations and reduce the amount of emitted air pollutants. There are several air pollution control devices, however, only wet scrubber is efficiently used to remove particulate matters and gaseous pollutants, even if it has minimum collection efficiency in the particle size range of $0.1{\sim}1{\mu}m$. This study aimed to improve the collection efficiency of a spray tower type scrubber by introducing an electrospray system with two-flow nozzle. We found that the collection efficiency of a spray tower type scrubber was similar to that of a conventional wet scrubber. However, installation of an electrospray system in the scrubber resulted in drastic further improvement of collection efficiency comparing to that of a conventional scrubber, which is 26%, 35.2%, and 45.1% at the liquid to gas ratio of 0.26 $L/m^3$ and 19.9%, 35.1%, and 42.5% at 0.34 $L/m^3$ for the applied voltage of -30 kV, -35 kV, and -40 kV, respectively. Therefore, we found that the introduction of an electrospray system is very effective to improve the collection efficiency of a spray tower type scrubber.

트랙터 부착 붐 방제기 노즐 분무특성 (Characteristic of Tractor Attachment Boom Sprayer Nozzle)

  • 강태경;김성우;김영근;이상희;최용;전현종;최일수;김형곤
    • 한국분무공학회지
    • /
    • 제21권4호
    • /
    • pp.195-199
    • /
    • 2016
  • Spraying of nozzles and design of tractor-attached boom sprayers have been studied for analysis of liquid spraying features. The following conclusions have been drawn. At all pressures, twin flat spray tips was finer than flat spray tips. A fine spray with VMD of 101 to 200 appeared at 1.5MPa. So, it was selected as the boom sprayer nozzle. In spraying uniformity analysis, Type B was proven to have more uniformity than Type A and Type C at 52.0 cm attached distance. Type A and Type C were proven to have more uniformity than Type B at 58.5 cm attached distance. It is concluded that these results reflect atomizing characteristics of nozzles during pest control with tractor-attached boom sprayer. Therefore, optimum setting will be putting Type C with 58.5 cm distance.

CRDI용 인젝터 드라이버 제작과 성능시험 (The Fabrication and Trial Performance of Injector Driver for CRDI)

  • 김상암;왕우경;김온
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.38-45
    • /
    • 2013
  • In this study, for carrying out the spray and combustion experiment using a Common Rail Direct Injection(CRDI) system, the controller was fabricated to drive a high speed camera, a injector and a laser beam sequentially at a low cost. CB280 module of one-chip micro processer was used for the controller. In order to confirm responsibility and utility of the controller, the current drive performance, the spray behavior and the injection rate were tested and analyzed under various experimental conditions. As this research results, we found that the fabricated controller was able to control the devices for the spray experiment precisely with the input value in program and it had the dynamic load responsibility and repetition. Also, we found that the injection rates of our experimental results were higher than those of others at the same injection pressure and the controller connected with the laser system and the data acquisition system had validity for carrying out the spray visualization experiment.

A Study on the Behavior of Evaporating Diesel Spray Using LIEF Measurement and KIVA Code

  • Yeom, Jeong-Kuk;Chung, Sung-Sik;Ha, Jong-Yul;Kim, Yong-Rae;Min, Kyoung-Doug
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2310-2318
    • /
    • 2004
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 400 bar to 800 bar by using a common rail injection system. Also, we conducted simulation study by modified KIVA-II code. The results of simulation study are compared with experimental results. The images of liquid and vapor phase for free spray were simultaneously taken by exciplex fluorescence method. As experimental results, the vapor concentration of injected fuel is leaner due to the increase of atomization in the case of the high injection pressure than in that of the low injection pressure. The calculated results obtained by modified KIVA-II code show good agreements with experimental results.

Spray characteristics of misaligned impinging injectors

  • Subedi, Bimal;Son, Min;Kim, Woojin;Choi, Jangsu;Koo, Jaye
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1257-1262
    • /
    • 2014
  • The variances of atomization characteristics with the misalignment of injectors defined as the fraction of skewness for various angles of impingement and pressure conditions were studied using the doublet impinging injectors with a like-on-like arrangement. Water was used as simulant and the spray characteristics along with the changes in the skewness were analyzed using the methods of spray image photography. Experiment was carried for the impinging nozzles of orifice diameter of 1.2 mm within Reynolds numbers ranging from $9{\times}10^3-4.5{\times}10^4$ and the fraction of skewness considered for the experiment ranges from 0.0 to 0.9 at ambient temperature condition. Flat sheet with a distinct rim produced perpendicular to the plane of impinging jets goes ondisappear and sheet appears comparatively shorterwith the increase in fraction of skewness resulting the atomization of fluid droplet very close to impingement point with decrease in breakup length and increase in spray angle up to certain extent. The maximum allowable skewness was found as the result. The skewness up to the certain extent can be considered as the parameter to control the atomization characteristics of simulant inside the combustion chamberproviding the high economic performance of fuel and time.

스월유동이 분무특성에 미치는 영향에 관한 연구 (Study on the Effect of Swirl Flow on Spray Characteristics)

  • 최승환;전충환;장영준
    • 한국분무공학회지
    • /
    • 제7권1호
    • /
    • pp.14-20
    • /
    • 2002
  • It is well known that the flow and spray characteristics is critical factor on the performance and emission of a direct injection diesel engine. So this study aims to investigate the interaction of flow and spray characteristics. At first, in cylinder flow distributions in swirl adaptor for 4-valve cylinder head of DI Diesel engine were investigated under steady conditions for different SCV angles mounted on the cylinder head with steady rig test and 2-D LDV. And the in-cylinder flow was quantified in terms of mean flow coefficient and swirl ratio/tumble ratio. It was found that the swirl ratio is controlled between 2.3 and 3.8. Then spray characteristics of the intermittent injection were investigated. PDA system was utilized for measurement of a droplet size and velocity. The analyses of the PDA results are carried out with Time Dividing Method. It was found that there is a correlation between the swirl flow and SMD. The droplet size and the velocity were nearly constant value with each SCV angle. And the swirl ratio is higher, SMD smaller. The swirl ratio was helpful factor to the atomization of droplet.

  • PDF

루프소기형태의 2행정기관에서 분사압력 및 분사각도에 따른 분무특성 연구 (Effects of Injection Pressure and Injection Angle on Spray Characteristics in Loop Scavenged Type 2-stroke Engines)

  • 채수;유홍선
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.165-176
    • /
    • 1996
  • The flow field and spray characteristics for loop scavenged type 2stroke engine having pancake shape was numerically computed using KIVA-Ⅱ code. The cylinder has 1intake port, 2side intake ports and 1exhaust port with induced flow angle 25 deg. In engine calculation, the chop techniques is used to strip or add planes of cells across the mesh adjacent to the TDC and the BDC(ports parts) for preventing the demand of exceed time during the computation, providing a control on cell height in the squish region. The modified turbulent model including the consideration of the compressibility effect due to the compression and expansion of piston was also used. The case of 25 deg.(injection angle) which is opposite to scavenging flow direction shows better the distribution of droplets and the evaporation rate of droplets compared to other cases(0 deg., - 25 deg.). When injection pressure was increased, the spray tip penetration became longer. When injection pressure was increased, the interaction between the upward gas velocity and spray droplets strongly cause. Thus the breakup of droplets is strongly occurred and the evaporation rate of droplets was found to be better.

  • PDF

가변추력을 위한 기체주입식 와류형 분사기의 분무특성 (Spray Characteristics of Effervescent Swirl Injectors for Variable Thrust)

  • 이원구;황동현;안규복;윤영빈
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.1-12
    • /
    • 2019
  • 액체로켓엔진에서의 추력조절을 위해 기체주입식 가변추력 방법에 대한 기초적인 연구를 수행하였다. 기체주입식 가변추력은 간단한 구조로 추력을 조절할 수 있을 뿐만 아니라 밀도 감소에 비례하여 증가된 분사차압에 의해 미립화 성능 증가라는 장점을 갖는다. 본 연구에서는 기체주입식 와류형 분사기를 이용하여 액체 질량유량과 기체주입량의 변화에 따른 분무 불안정, 분무형상, 분무각, 분열 길이와 같은 분무특성을 살펴보았다.