• Title/Summary/Keyword: Sprague-Dawley Rats

Search Result 3,881, Processing Time 0.038 seconds

Effects of Vitamin C on Residual Aflatoxin $B_1$ in Rat Sera Treated with Radiation and Aflatoxin $B_1$ (Vitamin C가 방사선과 Aflatoxin $B_1$을 투여한 흰쥐의 혈청 중 Aflatoxin $B_1$ 잔류량에 미치는 영향)

  • Chung, Do-Young;Kim, Han-Soo;Kang, Jin-Soon
    • Food Science and Preservation
    • /
    • v.18 no.3
    • /
    • pp.374-382
    • /
    • 2011
  • Aflatoxin ($AFB_1$) is a potent hepatotoxic and hepatocarcinogenic mycotoxin in humans. It is also well-known to be accumulated in animal tissues via various metabolic pathways. This study was conducted to determine the effects of vitamin C on the residual $AFB_1$ in rat sera that were treated with radiation and $AFB_1$. Six week-old male Sprague-Dawley rats were randomly divided into five groups: a control group, $AFB_1$-treated group, the group treated with $AFB_1$ and vitamin C, the group treated with X-ray and AFB1, and the group treated with X-ray and $AFB_1$ with vitamin C. On the first day of the experiment, only one dose of X-rays was exposed to the entire liver at 1,500 cGy. Next, vitamin C was injected at 10 mg/kg body weight via intraperitoneal injection, followed 1 hr later by the administration of 0.4 mg/kg of $AFB_1$ via intraperitoneal injection. These treatments were then administered every three days over a period of 15 days. On the 16th day of treatments, the animals were sacrificed. The contents of $AFB_1$ in rat sera were determined via indirect competitive ELISA and HPLC method. In the quantitative analysis of $AFB_1$ in rat sera via ELISA, $5.17{\pm}0.34$ ng/mL of $AFB_1$ was detected in the $AFB_1$-treated groups, but the amount more significantly decreased to $3.23{\pm}0.76$ ng/mL in the groups treated with $AFB_1$ and vitamin C (p<0.01) than in the $AFB_1$-treated groups. The $AFB_1$ contents of the rat sera of the groups treated with X-ray and $AFB_1$ did not significantly decreased with the administration of vitamin C. The $AFB_1$ content of the rat sera that was analyzed via HPLC showed a tendency similar to that of the content that was analyzed via ELISA. With regard to these data, vitamin C was very effective in reducing $AFB_1$ residue in rat sera.

Development of Anti-diabetes Drink Using with Silkworm(Bombyx mori L.) Extract (누에(Silkworm) 추출물을 이용한 기능성 항당뇨음료의 개발)

  • 최진호;김대익;박시향;백승진;김남주;류강선
    • Journal of Sericultural and Entomological Science
    • /
    • v.45 no.2
    • /
    • pp.96-102
    • /
    • 2003
  • This study was designed to develope the functional anti-diabetes drink, Dia-D using silkworm (Bombyx mori L) extract Sprague-Dawley (SD) male rats (160${\pm}$10g) were fed basic diet (control group), and experimental diets (SWE-l0, 30, 60 groups and Daonil-40, 80 groups) added silkworm extract 10, 30 and 60mg/day or diabetes drug prepared and marketed by Handok Pham. Co., Daonil 40 and 80 mg/day for 12 days. Blood glucose contents were significantly decreased 25-30% in SWE-30 and SWE-60 groups, and about 35% in Daonil 40 and Daonil 80 groups compared with control group. Triglyceride (TG) and lipid peroxide (LPO) contents were significantly inhibited 10-16% and 8-13%, respectively, in SWE-30 and 60 groups, whereas these contents were 13-30% and 15%, respectively, in Daonil-40 and 80 groups compared with control group. Hydroxyl radical (OH) contents were significantly inhibited 19-20% in SWE-30 and 60 groups, and 7-12% in Daonil-40 and 80 groups compared with control group. Superoxide dismutase (SOD) activities were significantly increased 11-14% in SWE-30 and 60 groups, and 12-29% in Daonil-40 and 80 groups compared with control group. In results of clinical test using normal subjects, blood glucose content tested in NIAST subjects as anti-diabetes drink, Dia-D willi 100mg/vial was significantly decreased 17.5%, and these content tested in PKNU subjects as anti-diabetes drink, Dia-D with 150mg/vial was significantly decreased 20.5% compared with control group. These results suggest that administration of Dia-D as an anti-diabetes drink prepared with silkworm extract may playa very effective role in a decreasing of blood glucose in hyperglycemia patients.

Effects of Ginsenoside Rb1 Loaded Films on Oral Wound Healing (Ginsenoside Rb1함유 필름의 구강 내 창상 회복 촉진 효과)

  • Jeong Hyun, Lee;Seung Hwan, Park;Asiri Naif, Mohammed;Myoung-Han, Lee;Dong-Keon, Kweon;Yongkwon, Chae;Koeun, Lee;Misun, Kim;Hyoseol, Lee;Sungchul, Choi;Ok Hyung, Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.300-309
    • /
    • 2022
  • This study aimed to evaluate the effects of two ginsenoside Rb1 (G-Rb1) loaded films on oral wound healing. Two types of G-Rb1 films, G-Rb1 loaded carboxymethyl cellulose (GCMC) film and G-Rb1 loaded hyaluronic acid (GHA) film, were developed. A total of 36 Sprague-Dawley rats were divided into 3 groups: control, GCMC, and GHA. After wound formation on midpalate, the control group was left without treatment, whereas the experimental groups had films attached. The specimen was analyzed clinically and histologically after 7 and 21 days. For clinical analysis, the area of incompletely re-epithelialized wound was measured. For histological analysis, the distance between the margins of the wound (soft tissue gap) was measured and the percentage of the collagen-stained area on the specimen was calculated. In clinical and soft tissue gap analysis, the GCMC group presented improved healing compared to the GHA group and the control at day 7 (p < 0.05). And, both GCMC (9.74 ± 10.12%) and GHA groups (19.50 ± 14.47%) presented greater collagen-positive pixels compared to control (0.89 ± 1.60%) at day 7 (p < 0.05). However, there were no differences in these parameters among the groups on day 21. Therefore, G-Rb1 loaded films improved oral wound healing.

Study on the Chemical Composition of Lotus Root and Functional Evaluation of Fermented Lotus Root Drink (연근의 성분분석 및 연근 발효음료의 기능성 평가)

  • Bae, Man-Jong;Kim, Soo-Jung;Ye, Eun-Ju;Nam, Hak-Sik;Park, Eun-Mi
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.2
    • /
    • pp.222-227
    • /
    • 2008
  • This study examined the chemical composition of lotus root and functionally evaluated a fermented lotus root drink. Electron-donating ability using DPPH along with nitrite-scavenging ability were used to compare the antioxidative activities of unfermented and fermented lotus root drinks. The electron-donating abilities of the unfermented lotus root drink (1%) and fermented lotusroot drink (1%) were 22.55% and 23.88%, respectively. At pH 6.0, the nitrite-scavenging abilities of the unfermented lotus root drink and the fermented lotus root drink (100%) were 27.64% and 40.3%, respectively, and their scavenging ability increased in a dose-dependent manner at all pH values. In order to study the anti-obesity effects of the two drinks, male Sprague-Dawley rats were divided into four groups (A: basal diet, B: high fat diet, C: high fat diet+unfermented lotus root drink, D: high fat diet+fermented lotus root drink). Net weight gains were not significantly different among the four groups. Plasma total cholesterol concentrations significantly decreased in the groups receiving the unfermented and fermented lotus root drinks. Also, plasma total lipid and triglyceride contents were lower in the groups receiving the unfermented and fermented lotus root drinks as compared to the high fat diet group; however, the differences among the three groups were not significant.

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF

Studies on the Repeated Toxicity Test of Food Red No.2 for 4 Weeks Oral Administration in SD Rat (SD랫드에서 식용색소 적색2호의 4주간 경구투여에 따른 반복독성시험에 관한 연구)

  • Yoo, Jin-Gon;Jung, Ji-Youn
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.42-49
    • /
    • 2012
  • This study was carried out to investigate the toxicity of food Red No.2 in the Sprague-Dawley (SD) female rat for 4 weeks. SD rats were orally administered for 28 days, with dosage of 500, 1,000, 2,000 mg/kg/day. Animals treated with food Red No.2 did not cause any death and show any clinical signs. They did not show any significant changes of body weight, feed uptake and water consumption. There were not significantly different from the control group in urinalysis, hematological, serum biochemical value and histopathological examination. In conclusion, 4 weeks of the repetitive oral medication of food Red No.2 has resulted no alteration of toxicity according to the test materials in the group of female rats with injection of 2,000 mg/kg. Therefore, food Red No.2 was not indicated to have any toxic effect in the SD rats, when it was orally administered below the dosage 2,000 mg/kg/day for 4 weeks.

Effects of FK224, a $NK_1$ and $NK_2$ Receptor Antagonist, on Plasma Extravasation of Neurogenic Inflammation in Rat Airways (미주 신경의 전기적 자극으로 유발된 백서의 기도내 혈장 유출에 대한 FK224의 효과)

  • Shim, Jae-Jeong;Lee, Sang-Yeub;Lee, Sang-Hwa;Park, Sang-Myun;Seo, Jeong-Kyung;Cho, Jae-Yun;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.744-751
    • /
    • 1995
  • Background: Asthma is an inflammatory disease because there are many inflammatory changes in the asthmatic airways. Axon reflex mechanisms may be involved in the pathogenesis of asthma. Sensory neuropeptides are involved in this inflammation, which is defined as neurogenic inflammation. Substance p, neurokinin A, and neurokinin B may be main neuropeptides of neurogenic inflammation in airways. These tachykinins act on neurokinin receptors. Three types of neurokinin receptors, such as $NK_1$, $NK_2$, and $NK_3$, are currently recognized, at which substance p, neurokinin A, and neurokinin B may be the most relevant natural agonist of neurogenic inflammation in airways. The receptor subtypes present in several tissues have been characterized on the basis of differential sensitivity to substance p, neurokinin A, and neurokinin B. Plasma extravasation and vasodilation are induced by substance p more potently than by neurokinin A, indicating NK1 receptors on endothelial cells mediate the response. But airway contraction is induced by neurokinin A more potently than by substance P, indicating the $NK_2$ receptors in airway smooth muscles. These receptors are used to evaluate the pathogenesis of brochial asthma. FK224 was identified from the fermentation products of Streptomyces violaceoniger. FK224 is a dual antagonist of both $NK_1$ and $NK_2$ receptors. Purpose: For a study of pathogenesis of bronchial asthma, the effect of FK224 on plasma extravasation induced by vagal NANC electrical stimulation was evaluated in rat airway. Method: Male Sprague-Dawley rats weighing 180~450gm were anesthetized by i.p. injection of urethane. Plasma extravasation was induced by electrical stimulation of cervical vagus NANC nerves with 5Hz, 1mA, and 5V for 2 minutes(NANC2 group) and for sham operation without nerve stimulation(control group). To evaluate the effect of FK224 on plasma extravasation in neurogenic inflammation, FK224(1mg/kg, Fujisawa Pharmaceutical Co., dissolved in dimethylsulphoxide; DMSO, Sigma Co.) was injected 1 min before nerve stimulation(FK224 group). To assess plasma exudation, Evans blue dye(20mg/kg, dissolved in saline) was used as a plasma marker and was injected before nerve stimulation. After removal of intravascular dye, the evans blue dye in the tissue was extracted in formamide($37^{\circ}C$, 24h) and quantified spectrophotometrically by measuring dye absorbance at 629nm wavelength. Tissue dye content was expressed as ng of dye per mg of wet weight tissue. The amount of plasma extravasation was measured on the part of airways in each groups. Results: 1) Vagus nerve(NANC) stimulation significantly increased plasma leakage in trachea, main bronchus, and peripheral bronchus compared with control group, $14.1{\pm}1.6$ to $49.7{\pm}2.5$, $17.5{\pm}2.0$ to $38.7{\pm}2.8$, and $12.7{\pm}2.2$ to $19.1{\pm}1.6ng$ of dye per mg of tissue(mean ${\pm}$ SE), respectively(p<0.05). But there was not significantly changed in lung parenchyma(p>0.05) 2) FK224 had significant inhibitory effect upon vagal nerve stimulation-induced airway plasma leakage in any airway tissues of rat,such as trachea, main bronchus, and peripheral bronchus compared with vagus nerve stimulation group, 49%, 58%, and 70%, respectively(p<0.05). Inhibitory effect of FK224 on airway plasma leakage in neurogenic inflammation was revealed the more significant in peripheral bronchus, but no significant in lung parenchyma. Conclusion: These results suggest that FK224 is a selective NK receptor antagonist which effectively inhibits airway plasma leakage induced by the endogenous neurotransmitters relased by neurogenic inflammation in rat airway. Tachykinin receptor antagonists may be useful in the treatment of brochial asthma.

  • PDF

Changes in Immunogenicity of Preserved Aortic Allograft (보존된 동종동맥편 조직의 면역성 변화에 관한 연구)

  • 전예지;박영훈;강영선;최희숙;임창영
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1173-1181
    • /
    • 1996
  • The causes of degenerative changes in allograft cardiac valves are not well known to this day. Today's preserved allografts possess highly viable endothelial cells and degeneration of allografts can be facilitated by immune reaction which may be mediated by these viable cells. To test the antigenicity of endothelial cells, pieces from aortic wall were obtained from fresh and cryo-preserved rat allograft. Timings of sampling were prior to sterilization, after sterilization, after 1, 2, 7, 14 days of fresh preservation and cryopreservation. Endothelial cells were tested by immunohistochemical methods using monoclonal antibodies to MHC class I(MRC OX-18), class II(MRC OX-6) and ICAM-1 antigens. After transplantation of each group of aortic allograft at the subcutaneous layers of rats, population of CD4$^{+}$ T cell and CD8$^{+}$ T cell were analyzed with monoclonal antibodies after 1, 2, 3, 4, 6 and 8 weeks. MHC class I expression was 23.95% before preservation and increased to 35.53~48.08% after preservation(p=0.0183). MHC Class II expression was 9.72% before preservation and 10.13~13.39% after preservation(P=0.1599). ICAM-1 expression was 15.02% before preservation and increased to 19.85~35.33% after preservation(P=0.001). The proportion of CD4$^{+}$ T-cell was 42.13% before transplantation. And this was 49.23~36.8% after transplantation in No treat group (p=0.955), decreased to 29.56~32.80% in other group(p=0.0001~0.008). In all the groups, the proportion of CD8$^{+}$ T-cell increased from 25.57% before transplantation to 42.32~58.92% after transplantation(p=0.000l~0.0002). The CD4$^{+}$/CD8$^{+}$ ratio decreased from 1.22~2.28 at first week to 0.47~0.95 at eighth week(p=0.0001). The results revealed that the expression of MHC class I and ICAM-1 in aortic allograft endothelium were increased but that of MHC class II were not changed, despite the different method of preservation. During 8 weeks after transplantation of aortic allograft, the subpopulations of CD4$^{+}$ T cell were not changed or only slightly decreased but those of CD8$^{+}$ T cell were progressively increased.ely increased.

  • PDF

Changes of the blood chemistry, lipid and protein components in blood and liver tissue of the rat after oral combined administration of caffeine, iron and vitamin E (Caffeine, 철분 및 vitamin E 혼합투여시 rat의 혈액과 간조직내에서 혈액화학성분과 지질 및 단백질 구성성분의 변화)

  • Do, Jae-cheul;Huh, Rhin-sou
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.577-598
    • /
    • 1996
  • This study was conducted to identify the effects of caffeine or combinations of caffeine and iron or vitamin E on the lipid and protein components or blood chemistry levels of the serum as well as the total homogenate, mitochondrial and microsomal fraction of the rat(Sprague-Dawley, female) liver. Chronic test were conducted to determine those effects. The chronic test was conducted by dividing rats into 5 groups according to the type of drugs and dosages administrated as follows; the control(group A), and group B was given 25mg/kg caffeine orally once daily for 30 days, group C was given 50mg/kg caffeine orally once daily for 30 days, group D was given 25mg/kg caffeine and orally ferric chloride once daily for 30 days and group E was given 25mg/kg caffeine and 25mg/kg vitamin E once daily for 30 days. The concentrations of glucose, urea nitrogen, uric acid, creatinine, total protein, albumin, A/G ratio, triglyceride, total cholesterol, HDL-cholesterol, free fatty acid, phospholipid as well as the activities of alanine aminotransferase(ALT), aspartate aminotransferase(AST) and alkaline phosphatase(ALP) were measured in the serum of each experimental groups. The concentrations of the carbonyl group and malondiaidehyde(MDA) and the patterns of the SDS-PAGE(Sodium Dodecyl Sulfate - Polyacrylamide Gel Electrophoresis) and fatty acid compositions in free fatty acids and phospholipids were analyzed to determine the oxidative damages and metabolic changes on the lipid and protein components in the serum, and total homogenate, mitochondrial and microsomal fractions of the rat liver. The results obtained from this study were summarized as follows; 1. Body weights of groups B, C, D and E were significantly decreased(p < 0.01) in comparison with that of the control in the chronic test. 2. The concentrations of serum glucose in groups B(124.5mg/dl), C(130.1mg/dl), D(122.1mg/dl), E(119.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(101.5mg/dl). But, there were no significant differences in the concentrations of urea nitrogen, uric acid, creatinine, total protein, albumin and A/G ratio in comparison to that of the control. 3. The concentrations of total cholesterol and HDL-cholesterol in serum of groups B(69.6, 53.4mg/dl), C(73.0, 56.3mg/dl), D(68.9, 51.1mg/dl) and E(68.2, 51.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(52.6, 38.8mg/dl). On the other hand, the concentrations of triglyceride in serum of groups B(45.0mg/dl), C(40.4mg/dl), D(33.8mg/dl) and E(47.2mg/dl) were significantly lower(p < 0.01) in comparison to that of the control(66.2mg/dl). There were no significant differences in the activities of ALT, AST and ALP in comparison to that of the control. 4. The concentrations of free fatty acid and phospholipid in serum of groups B(45.7, 154.4mg/dl), C(50.0, 167.2mg/dl), D(52.5, 148.4mg/dl) and E(41.1, 159.2mg/dl) were higher(p < 0.01) in comparison to that of the control(35.2, 125.3mg/dl). And the concentrations of the carbonyl group and malondialdehyde in serum of group D(1.82, 0.52nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(1.53nM/mg protein). 5. The concentrations of carbonyl group in total homogenate, mitochondrial and microsomal fraction of group D(1.45, 0.94, 1.67nM/mg protein) were significantly higher (p < 0.01) in comparison to the control(1.16, 0.66, 1.27nM/mg protein). And the concentrations of malondialdehyde in the total homogenate, mitochondrial and microsomal fraction of group D(6.70, 6.10, 1.36nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(5.17, 3.64, 0.68nM/mg protein). 6. As the analytical results of the fatty acid compositions of free fatty acid in serum, the proportions of stearic acid and arachidonic acid of groups B(16.52, 12.62%), C(17.52, 15.18%), D(19.73, 13.47%) and E(17.62, 13.28%) were significantly higher(p < 0.01) in comparison to the control(14.75, 7.88%), but the proportions of oleic acid and linoleic acid of groups B(12.97, 32.59%), C(10.88, 31.23%), D(12.37, 30.66%) and E(11.95, 32.41%) were significantly lower(p < 0.01) in comparison to the control(16.44, 35.12%). Otherwise, as the results of the fatty acid compositions of phospholipid in serum, the proportions of stearic acid and arachidonic acid of groups B(39.37, 16.39%), C(40.63, 17.83%), D(42.73, 15.39%) and E(39.16, 15.70%) were significantly higher(p < 0.01) in comparison to the control(37.74, 14.24%), but the proportions of oleic acid and linoleic acid of groups B(4.03, 14.38%), C(3.54, 12.38%), D(4.52, 11.68%) and E(4.29, 13.64%) were significantly lower(p < 0.01) in comparison to the control(5.53, 16.14%). 7. As the analytical results of the fatty acid compositions of free fatty acid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of oleic acid of groups B(7.8**, 8.73**, 6.88%) and C(6.89**, 7.75**, 6.58%) were lower(**:p < 0.01) in comparison to the control(8.67, 10.08, 7.81%), but the proportions of arachidonic acid of group C(22.62, 19.79, 23.71%) were significantly higher(p < 0.01) in comparison to the control(20.93, 18.47, 22.24%). And the proportions of palmitic acid of group D(25.95**, 26.16, 26.34**%) were significantly higher(**:p < 0.01) in comparison to the control(24.43, 25.42, 23.34%). In addition, the proportions of linoleic acid of group D(23.43, 25.02, 23.95%) were also significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). The proportions of stearic acid of group D(19.87, 19.76**%) in mitochondrial and microsomal fraction were lower(**:p < 0.01) in comparison to the control(21.01, 24.18%), and the proportions of stearic acid of group E(16.71*, 19.65**%) in mitochondrial and microsomal fraction were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(21.01, 24.18%), and the proportions of linoleic acid of group E(25.04, 29.20, 26.48%) in total homogenate, mitochondria and microsome were significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). 8. As the results of the fatty acid compositions of phospholipid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of palmitic acid of group D(17.58**, 18.78*, 18.23%**) were significantly higher(**:p < 0.01, *:p < 0.05) in comparison to the control(16.28, 17.22, 16.38%), and the proportions of stearic acid of group D(36.41, 37.23, 39.53%) were also significantly higher(p < 0.01) in comparison to the control(34.18, 34.16, 36.04%). But the proportions of oleic acid(3.41*, 3.11**, 3.12**%) and linoleic acid (18.03**, 15.79**, 14.74**%) of group D were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(oleic : 3.63, 3.72, 3.79%, linoleic : 20.03, 18.71, 18.48%). 9. In order to determine the oxidative damages to the protein in serum, mitochondrial and microsomal fraction of the rat liver, the patterns of the SDS-PAGE were identified, but the results of SDS-PAGE were not significantly different between the control and experimental groups.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF