• 제목/요약/키워드: Spot measurement

검색결과 234건 처리시간 0.029초

연삭 가공면의 표면조도와 형상정밀도의 비접촉식 인프로세스 측정기술 (An In-Process Measurement Technique for Non-contact Monitoring of Surface Roughness and form Accuracy of Ground Surfaces)

  • 임동열
    • 한국정밀공학회지
    • /
    • 제4권2호
    • /
    • pp.36-46
    • /
    • 1987
  • An optical technique using laser for non-contact measurement of surface roughness and form accuracy of ground surfaces is presented. It is found that, when a ground surface is illuminated by a beam of laser light, the roughness height and slope distribution has significant influence on the pattern of reflection and it maintains an unique Gaussian distribution relationship with the surface roughness. The principle idea of the optical measurement system is therefore monitor the radiation, and then calibrate it in process against surface roughness by means of necessary digital data processing. On the other hand, measuring the form accuracy of a ground surface is accomplished by using a triangular method, which is based on observing the movement of an image of a spot of light projected onto the surface. The image is focused, through a series of lenses for magnification, on a photodetector array lf line configur- ation. Then the relative movement of image and consequently the form accuracy of the surface can be obtained through appropriate calibration procedures. Experimental test showed that the optical roughness measurement technique suggested in this work is very efficient for most industrial applications being capable of monitoring the roughness heights ranging 0.1 to 0.6 .$\mu$m CLA values. And form accuracy can be measured in process with a resolution of 10 .$\mu$m.

  • PDF

자유공간 기법을 적응한 마이크로파 대역 전파흡수재의 유전 특성 분석 (A Free-Space Method for Measurement and Analysis of Dielectric Characteristics of Electromagnetic Absorbing Materials at Microwave Frequencies)

  • 배근식
    • 한국군사과학기술학회지
    • /
    • 제6권2호
    • /
    • pp.73-82
    • /
    • 2003
  • For measurements and analysis of dielectric characteristics of planar slabs of microwave absorbing materials, I have applied a free-space method in the frequency range of 8~14 GHz. The measurement system for free-space method consists of transmit and receive antennas, mode transitions, precision coaxal cables, the network analyzer, and a computer Special Spot-focused horn lens antenna was used to eliminate diffraction effects. Diffraction effects at the edges of the sample are minimized by satisfying the condition for minimum transverse dimension of the plate and the beamwidth of the antennas at the focus. The time-domain gating feature of the network analyzer and the thru, reflect, and line(TRL) calibration technique were used to eliminate the effects of undesirable multiple reflections. The complex coefficients of reflection and transmission, $S_{11}$ and $S_{21}$, of planar samples were measured for standard materials such as Teflon, Rexolite$\textregistered$ 2200. The results were compared with existing measurement method. And I applied a free-space method for measurement to measure dielectric constants of some electromagnetic absorbing materials. Dielectric properties for the same samples were also measured with a 7mm coxial transmission line method for purposes of comparison with the free-space method.

효율적 품질관리를 위한 지능형 다짐 시스템 개발 (Development of Intelligent Compaction System for Efficient Quality Control)

  • 이수민;박상일;이리호;서종원
    • 대한토목학회논문집
    • /
    • 제38권5호
    • /
    • pp.751-760
    • /
    • 2018
  • 현재 다짐공사는 작업자가 정해진 다짐횟수, 두께, 속도, 진동여부 등을 자신의 경험에 의해 개별적으로 판단하고 감독자의 육안 검사에 의해 다짐공사의 품질측정이 이루어지고 있으며, 작업 후 대표성이 떨어지는 재래식 다짐강도 측정방법인 일점시험(Spot test)을 통하여 후속 단계의 작업을 진행하고 있는 실정이다. 따라서 다짐작업 결과에 대한 정량적 확인이 불가능하며, 시공부실로 인한 문제점이 제기될 가능성이 상존하고 있다. 본 연구에서는 여러 가지 시험조건에서 실제 현장규모로 다짐을 수행한 후 연속 다짐강도 측정 방법과 재래식 다짐강도 측정 방법과의 비교를 통해 연속 다짐강도 측정 방법의 사용 타당성을 입증하였다. 타당성 입증은 연속 다짐강도 측정방법인 GPS (Global Positioning System)와 가속도계로 구성된 IC (Intelligent Compaction) 롤러의 CMV (Compaction Meter Value)를 분석하는데 있으며, 입증된 결과를 토대로 일점시험을 배제한 현장 전 범위 품질확인이 가능하다. 품질 확인은 본 연구에서 개발한 다짐공사 관제프로그램에 시각화되며, 이를 통해 현장관리자는 다짐작업과 동시에 실시간 품질 모니터링이 가능하다.

Plasma Current에 의한 Tokamak Poroidal Field Coil의 Inductance 특성 (Inductance Characteristics of Tokamak Poroidal Field Coil by the Plasma Current)

  • 정윤도;이승제;김태중;김기만;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.801-803
    • /
    • 2000
  • The large scale magnets like thermalnuclear fusion devices are necessary for superconducting CICC cable, When the Cable In Conduit Conductors(CICC) is occurred by the external turbulence, the CICC occurs to quench, The CICC can be broken because the CICC spends all energy in the quench-happened spot. Therefore, it is necessary to develop measurement systems of the quench detection. The measurement systems of the relative good degree of efficiency are the voltage tap sensors. The weak points of voltage tap sensors are effected by EMF noise and inductance. The thermalnuclear fusion devices easily can't measure inductance value because of plasma current. In the experiment, The value of inductance was estimated by FEM techniques and the decrement of Inductance value measured as long as remaining plasma current.

  • PDF

HDR이미지를 이용한 공동주택 외부조명의 휘도 분석 (Luminance Analysis of the Apartment Exterior Lighting using HDR Images)

  • 홍승대;신은주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권2호
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권5호
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

Improving the Capture-range Problem in Phase-diversity Phase Retrieval for Laser-wavefront Measurement Using Geometrical-optics Initial Estimates

  • Li, Li Jie;Jing, Wen Bo;Shen, Wen;Weng, Yue;Huang, Bing Kun;Feng, Xuan
    • Current Optics and Photonics
    • /
    • 제6권5호
    • /
    • pp.473-478
    • /
    • 2022
  • To overcome the capture-range problem in phase-diversity phase retrieval (PDPR), a geometrical-optics initial-estimate method is proposed to avoid a local minimum and to improve the accuracy of laser-wavefront measurement. We calculate the low-order aberrations through the geometrical-optics model, which is based on the two spot images in the propagation path of the laser, and provide it as a starting guess for the PDPR algorithm. Simulations show that this improves the accuracy of wavefront recovery by 62.17% compared to other initial values, and the iteration time with our method is reduced by 28.96%. That is, this approach can solve the capture-range problem.

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • 제1권1호
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.