• Title/Summary/Keyword: Spot measurement

Search Result 234, Processing Time 0.022 seconds

An In-Process Measurement Technique for Non-contact Monitoring of Surface Roughness and form Accuracy of Ground Surfaces (연삭 가공면의 표면조도와 형상정밀도의 비접촉식 인프로세스 측정기술)

  • Yim, Dong-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.2
    • /
    • pp.36-46
    • /
    • 1987
  • An optical technique using laser for non-contact measurement of surface roughness and form accuracy of ground surfaces is presented. It is found that, when a ground surface is illuminated by a beam of laser light, the roughness height and slope distribution has significant influence on the pattern of reflection and it maintains an unique Gaussian distribution relationship with the surface roughness. The principle idea of the optical measurement system is therefore monitor the radiation, and then calibrate it in process against surface roughness by means of necessary digital data processing. On the other hand, measuring the form accuracy of a ground surface is accomplished by using a triangular method, which is based on observing the movement of an image of a spot of light projected onto the surface. The image is focused, through a series of lenses for magnification, on a photodetector array lf line configur- ation. Then the relative movement of image and consequently the form accuracy of the surface can be obtained through appropriate calibration procedures. Experimental test showed that the optical roughness measurement technique suggested in this work is very efficient for most industrial applications being capable of monitoring the roughness heights ranging 0.1 to 0.6 .$\mu$m CLA values. And form accuracy can be measured in process with a resolution of 10 .$\mu$m.

  • PDF

A Free-Space Method for Measurement and Analysis of Dielectric Characteristics of Electromagnetic Absorbing Materials at Microwave Frequencies (자유공간 기법을 적응한 마이크로파 대역 전파흡수재의 유전 특성 분석)

  • 배근식
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • For measurements and analysis of dielectric characteristics of planar slabs of microwave absorbing materials, I have applied a free-space method in the frequency range of 8~14 GHz. The measurement system for free-space method consists of transmit and receive antennas, mode transitions, precision coaxal cables, the network analyzer, and a computer Special Spot-focused horn lens antenna was used to eliminate diffraction effects. Diffraction effects at the edges of the sample are minimized by satisfying the condition for minimum transverse dimension of the plate and the beamwidth of the antennas at the focus. The time-domain gating feature of the network analyzer and the thru, reflect, and line(TRL) calibration technique were used to eliminate the effects of undesirable multiple reflections. The complex coefficients of reflection and transmission, $S_{11}$ and $S_{21}$, of planar samples were measured for standard materials such as Teflon, Rexolite$\textregistered$ 2200. The results were compared with existing measurement method. And I applied a free-space method for measurement to measure dielectric constants of some electromagnetic absorbing materials. Dielectric properties for the same samples were also measured with a 7mm coxial transmission line method for purposes of comparison with the free-space method.

Development of Intelligent Compaction System for Efficient Quality Control (효율적 품질관리를 위한 지능형 다짐 시스템 개발)

  • Lee, Soomin;Park, Sangil;Lee, Riho;Seo, Jongwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.751-760
    • /
    • 2018
  • Currently, the quality measurement of the work is carried out by the supervisor's visual inspection, as the workers individually judge the number of resolutions, thickness, speed and vibration. After work, we are conducting follow-up work through traditional spot test, which is less representative. Therefore, it is impossible to check the results of the resolution, and there is always the possibility that problems will arise due to poor construction. This study demonstrates the feasibility of using the continuous compaction strength measurement method by comparing the continuous compaction strength measurement method and the conventional compaction strength measurement method after performing the compaction in the actual field scale in various test conditions. The validity is verified by analyzing the Compaction Meter Value of an Intelligent Compaction roller composed of a Global Positioning System and an accelerometer, Based on the proven results, a full range of quality can be confirmed without a single test. The quality confirmation is visualized in the compaction control program developed in this study, This enables the field manager to perform real-time quality monitoring at the same time as compaction.

Inductance Characteristics of Tokamak Poroidal Field Coil by the Plasma Current (Plasma Current에 의한 Tokamak Poroidal Field Coil의 Inductance 특성)

  • Chung, Yoon-Do;Lee, Seung-Je;Kim, Tae-Joong;Kim, Kee-Man;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.801-803
    • /
    • 2000
  • The large scale magnets like thermalnuclear fusion devices are necessary for superconducting CICC cable, When the Cable In Conduit Conductors(CICC) is occurred by the external turbulence, the CICC occurs to quench, The CICC can be broken because the CICC spends all energy in the quench-happened spot. Therefore, it is necessary to develop measurement systems of the quench detection. The measurement systems of the relative good degree of efficiency are the voltage tap sensors. The weak points of voltage tap sensors are effected by EMF noise and inductance. The thermalnuclear fusion devices easily can't measure inductance value because of plasma current. In the experiment, The value of inductance was estimated by FEM techniques and the decrement of Inductance value measured as long as remaining plasma current.

  • PDF

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

Improving the Capture-range Problem in Phase-diversity Phase Retrieval for Laser-wavefront Measurement Using Geometrical-optics Initial Estimates

  • Li, Li Jie;Jing, Wen Bo;Shen, Wen;Weng, Yue;Huang, Bing Kun;Feng, Xuan
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.473-478
    • /
    • 2022
  • To overcome the capture-range problem in phase-diversity phase retrieval (PDPR), a geometrical-optics initial-estimate method is proposed to avoid a local minimum and to improve the accuracy of laser-wavefront measurement. We calculate the low-order aberrations through the geometrical-optics model, which is based on the two spot images in the propagation path of the laser, and provide it as a starting guess for the PDPR algorithm. Simulations show that this improves the accuracy of wavefront recovery by 62.17% compared to other initial values, and the iteration time with our method is reduced by 28.96%. That is, this approach can solve the capture-range problem.

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.