• Title/Summary/Keyword: Split strength

Search Result 253, Processing Time 0.02 seconds

Influence of silpozz and rice husk ash on enhancement of concrete strength

  • Panda, K.C.;Prusty, S.D.
    • Advances in concrete construction
    • /
    • v.3 no.3
    • /
    • pp.203-221
    • /
    • 2015
  • This paper presents the results of a study undertaken to investigate the enhancement of concrete strength using Silpozz and Rice Husk Ash (RHA). The total percentage of supplementary cementitious material (SCM) substituted in this study was 20%. Six different concrete mixes were prepared such as without replacement of cement with silpozz and RHA (0% silpozz and 0% RHA) is treated as conventional concrete, whereas in other five concrete mixes cement was replaced by 20% of silpozz and RHA as (0% silpozz and 20% RHA), (5% silpozz and 15% RHA), (10% silpozz and 10% RHA), (15% silpozz and 5% RHA) and (20% silpozz and 0% RHA) with decreasing water-binder (w/b) ratio i.e. 0.375, 0.325 and 0.275 and increasing super plasticiser dose. New generation polycarboxylate base water reducing admixture i.e., Cera Hyperplast XR-W40 was used in this study. The results of this research indicate that as w/b decreases, super plasticiser dose need to be increased so as to increase the workability of concrete. The effects of replacing cement by silpozz and RHA on the compressive strength, split tensile strength and flexural strength were evaluated. The concrete mixture with different combination of silpozz and RHA gives higher strength as compared to control specimen for all w/b ratios and also observed that the early age strength of concrete is more as compared to the later age strength. It is also observed that the strength enhancement of concrete mixture prepared with the combination of cement, silpozz and RHA is higher as compared to the concrete mixture prepared with cement and silpozz or cement and RHA.

Monitoring of Fish Aggregations Responding to Artificial Reefs Using a Split-beam Echo Sounder, Side-scan Sonar, and an Underwater CCTV Camera System at Suyeong Man, Busan, Korea (소너 및 수중 CCTV 카메라 시스템을 이용한 수영만 인공어초 주변에 군집한 어군의 모니터링)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.3
    • /
    • pp.266-272
    • /
    • 2013
  • The objective of this study was to monitor and evaluate the schooling characteristics, including the distribution density (volume backscattering strength) and acoustic size (target strength), of commercially valuable species swimming in response to artificial reefs installed at Suyeong Man, Busan, Korea. Fish aggregations at two artificial reef areas and at a nearby natural rocky reef habitat were recorded and analyzed using a 70 kHz split-beam echo sounder and 330 kHz side-scan sonar from August to September, 2006. An underwater CCTV camera system was also used to observe marine organisms in physical contact with and swimming very close to artificial reefs. During the acoustic observations at three reef sites, useful information about schooling characteristics of fish aggregations responding to artificial reefs were obtained, but more trials are needed to confirm significant differences in schooling behavior and geographical distributions in areas containing natural reef structures and artificial reefs.

An Analytical Approach to the Flight Safety of Split Yaw Swaged Rod for a Rotor Craft (회전익기 요 스웨지드 로드 분할에 따른 비행 안전성에 대한 해석적 접근)

  • Lim, Hyun-Gyu;Choi, Jae-hyung;Kim, Dae-Han;Jang, Min-Wook;Yoon, Jae-Huy;Yang, Pil-Joo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.3
    • /
    • pp.74-80
    • /
    • 2017
  • As for A rotary wing aircraft, the configuration change about split yaw swaged rod was executed to improve hit treat capability for dealing with a long rod. The purpose of this study was to analyze if or not the quality of the split yaw swaged rod was obtained, and so the flight safety was ensured or not. Buckling analysis, Coupling Thread Strength Analysis, Thermal Stress analysis and Rod Natural Frequency Analysis were executed for structural analysis. The results of the analysis were presented that the split rod had the sufficient margin of safety and so there were no anomalies in the limit load and no failures in the ultimate load. And there were no resonances in result of natural frequency analysis. In conclusion, this study showed that the split yaw swaged rod had structural safety, so flight safety of rotary wing aircraft was secured and there was no problem in aircraft operation. It is certain that the technology of splitting the yaw swage rod will contribute to the operational Safety of the rotary wing aircraft in the future.

Construction of a Data Bank for Acoustic Target Strength with Fish Species, Length and Acoustic Frequency for Measuring Fish Size Distribution (어류 체장의 자동 식별을 위한 어종별, 체장별 및 주파수별 음향 반사 강도의 데이터 뱅크 구축)

  • LEE Dae-Jae;SHIN Hyeong-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.4
    • /
    • pp.265-275
    • /
    • 2005
  • A prerequisite for deriving the abundance estimates from acoustic surveys for commercially important fish species is the identification of target strength measurements for selected fish species. In relation to these needs, the goal of this study was to construct a data bank for converting the acoustic measurements of target strength to biological estimates of fish length and to simultaneously obtain the target strength-fish length relationship. Laboratory measurements of target strength on 15 commercially important fish species were carried out at five frequencies of 50, 70, 75, 120 and 200 kHz by single and split beam methods under the controlled conditions of the fresh and the sea water tanks with the 389 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $+45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N $(-5.0^{\circ},\;15.0^{\circ})$. The TS to fish length relationship for each species was independently derived by a least-squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to a fish length, wavelength and fish species. For four of the frequencies (50, 75, 120 and 200 kHz), an empirical model for fish target strength (TS, dB) averaged over the dorsal sapect of 602 fishes of 10 species and which spans the fish length (L, m) to wavelength (\Lambda,\;m)$ ratio between 5 and 73 was derived: $TS=19.44\;Log(L)+0.56\;Log(\Lambda)-30.9,\;(r^2=0.53)$.

Potential use of mine tailings and fly ash in concrete

  • Sunil, B.M.;Manjunatha, L.S.;Ravi, Lolitha;Yaragal, Subhash C.
    • Advances in concrete construction
    • /
    • v.3 no.1
    • /
    • pp.55-69
    • /
    • 2015
  • Tailing Material (TM) and Fly Ash (FA) are obtained as waste products from the mining and thermal industries. Studies were carried out to explore the possibility of utilizing TM as a part replacement to fine aggregate and FA as a part replacement to cement, in concrete mixes. The effect of replacing fine aggregate by TM and cement by FA on the standard sized specimen for compressive strength, split tensile strength, and flexural strengths are evaluated in this study. The concrete mix of M40 grade was adopted with water cement ratio equal to 0.40. Concrete mix with 35% TM and 65% natural sand (TM35/S65) has shown superior performance in strength as against (TM0/S100, TM30/S70, TM40/S60, TM50/S50, and TM60/S40). For this composition, studies were performed to propose the optimal replacement of Ordinary Portland Cement (OPC) by FA (Replacement levels studied were 20%, 30%, 40% and 50%). Replacement level of 20% OPC by FA, has shown about 0-5% more compressive strength as against the control mix, for both 28 day and 56 days of water curing. Interestingly results of split tensile and flexural strengths for 20% OPC replaced by FA, have shown strengths equal to that of no replacement (control mix).

Effect of air-jet texturing conditions on the physical properties of split-type ultrafine P/N filaments

  • Lee Eun-Ju;Bok Jin-Seon;Ju Chang-Hwan
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1998.10a
    • /
    • pp.394-397
    • /
    • 1998
  • Characteristics of air-jet textured yarns are determined by linear density, strength, and instability together with structural properties. Such characteristics are affected by various processing parameters and supply yam properties. In this Paper, specially, we have studied on the effect of air jet texturing conditions not only on texturing characteristics but also on splitting behavior using split-type ultrafine P/N filaments and their draw textured yarns as raw materials. (omitted)

  • PDF

Effect of Relative Levels of Mineral Admixtures on Strength of Concrete with Ternary Cement Blend

  • Mala, Kanchan;Mullick, A.K.;Jain, K.K.;Singh, P.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.3
    • /
    • pp.239-249
    • /
    • 2013
  • In the present scenario to fulfill the demands of sustainable construction, concrete made with multi-blended cement system of OPC and different mineral admixtures, is the judicious choice for the construction industry. Silica fume (SF) and fly ash (FA) are the most commonly used mineral admixtures in ternary blend cement systems. Synergy between the contributions of both on the mechanical properties of the concrete is an important factor. This study reports the effect of replacement of OPC by fly ash (20, 30, 40 and 50 % replacement of OPC) and/or silica fume (7 and 10 %) on the mechanical properties of concrete like compressive strength and split tensile strength, with three different w/b ratio of 0.3, 0.4 and 0.45. The results indicate that, as the total replacement level of OPC in concrete using ternary blend of OPC + FA + SF increases, the strength with respect to control mix increases up to certain replacement level and thereafter decreases. If the cement content of control mixes at each w/b ratio is kept constant, then as w/b ratio decreases, higher percentage of OPC can be replaced with FA + SF to get 28 days strength comparable to the control mix. A new method was proposed to find the efficiency factor of SF and FA individually in ternary blend cement system, based on principle of modified Bolomey's equation for predicting compressive strength of concrete using binary blend cement system. Efficiency factor for SF and FA were always higher in ternary blend cement system than their respective binary blend cement system. Split tensile strength of concrete using binary and ternary cement system were higher than OPC for a given compressive strength level.

Proposal of Connection Details for a Double Split Tee Connection Without a Shear tap (전단탭이 없는 상·하부 스플릿 티 접합부의 접합부상세 제안)

  • Yang, Jae Guen;Lee, Hyung Dong;Kim, Yong Boem;Pae, Da Sol
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.423-433
    • /
    • 2015
  • A double split tee connection, which is a beam-column moment connection, shows different behavioral characteristics under the influences of the thickness of a T-stub flange, a high-strength bolt gauge distance, and the number and diameter of a high-strength bolt. A double split tee connection is idealized and designed that a flexural moment normally acting on connections can be resisted by a T-stub and a shear force by a shear tap. However, where a double split tee connection is adopted to a low-and medium-rise steel structure, a small-sized beam member can be adopted. Then, a shear tab may not be bolted to the web of a beam. This study was conducted to suggest the details of a connection to secure that a double split tee connection with a geometric shape has a sufficient capacity to resist a shear force. To verify this, this study was conducted to make a three-dimensional nonlinear finite element analysis on a double split tee connection.

Mechanical Properties of Polymer Concrete Using Waste Lime Stone (석회석 폐석을 이용한 폴리머 콘크리트의 역학적 성질)

  • 연규석;유능환;민경원;주명기;최동순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.77-83
    • /
    • 1996
  • This study evaluated mechanical characteristics of polymer concrete produced using waste lime stone aggregate. Study results showed that compressive strength, flexural strength, split tensile strength and fracture toughness were very high. Therefore, it was concluded that waste lime stone could be used as aggregate in polymer concrete production through appropriate processing.

  • PDF

An Experimental Study on the Structural Characteristics of Tension Joints with High-Strength Bolted Split-Tee Connection (고력볼트 스플릿-티 인장접합부의 구조성능에 관한 실험적 연구)

  • Choi, Sung Mo;Lee, Seong Hui;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.737-745
    • /
    • 2004
  • In general, most of the beam-to-column connections for steel structures are regarded as either rigid connections or pin connections. Recently, the concept of a semi-rigid connection was introduced for a correct analysis of steel structures. Several experimental and theoretical researches have been performed regarding the structural behaviors of frames and buildings with semi-rigid connections. The results are not well known, and structural frame/building has not been designed to introduce the concept of semi-rigid connections between a beam and column until this time. To resolve this, this research depends on design specifications prepared by other advanced countries for the design of buildings with semi-rigid connections. Such a specification, however, should incorporate domestic characteristics of steel material properties and load conditions. This paper deals with structural capacities and deformable behaviors for a split-T tensile connection with F10T high-strength bolts to investigate the structural characteristics of semi-rigid frames. The experimental parameters include the thickness of T-flanges, painted or not, preloaded or not, and load pushover pattern. A total of 20 specimens were fabricated and tested with a 300-ton UTM. The structural capacities and behavior for split-T tensile connections were evaluated on each research parameter.