• Title/Summary/Keyword: Spiral test

Search Result 193, Processing Time 0.03 seconds

AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS (근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가)

  • Kim, Sung-Young;Lee, Mi-Jeong;Moon, Jang-Won;Lee, Se-Joon;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • The aim of this study was to evaluate the effectiveness of sealer placement in simulated root canal extensions. Forty resin blocks were attained from the Endo-training Bloc. In each block. The simulated root canal was made with $\#20$, 80taper GT file. After each block was longitudinally split into two halves, a standardized groove was prepared on one canal wall of two halves to simulate the canal extensions with various irregularities. The two halves of each block were assembled and all simulated root canals were obturated by single cone method with AH26 sealer. Four different methods of sealer placement were used: group A, $\#20$ K-file; group B, ultrasonic file; group C, lentulo spiral; group D, EZ-Fill bi-directional spiral. All obturated blocks were stored in $100\%$ humidity at $37^{\circ}C$ for 1 week, Using a low speed saw, each block was sectioned horizontally. Images of the sections were taken using a stereomicroscope at $\times$ 30 magnification and a digital camera. The amount of the sealer in the groove was evaluated using a scoring system, a higher score indicated better sealing effectiveness. The data was statistically analysed by Fisher's Exact Test. The sealing score was the lowest, specially at the middle area of canal extensions in group A, and that was statistically significant difference from other groups. In conclusion, the ultrasonic file, lentulo spiral and EZ-Fill bi-directional spiral were effective methods of sealer placement in simulated canal extensions. The K file was the least effective method, specially at the middle area of canal extensions.

Study of a Model Turbine Design Case Via Application of Spiral Case and Draft Tube Shape in Hydraulic Power Plant Modernization (수력 현대화 개·대체 시 스파이럴 케이스와 흡출관 형상에 따른 모델수차 설계 적용사례 연구)

  • Park, Nohyun;Kim, Jin-Hyuk;Kim, Seung-Jun;Hyun, Jungjae;Choi, Jongwoong;Cho, Yong
    • New & Renewable Energy
    • /
    • v.16 no.2
    • /
    • pp.35-46
    • /
    • 2020
  • Recently, turbines operating in hydro power plants are required to undergo renovation and modernization due to their age exceeding 30 years. In the process of renovation or modernization, a performance test of the scaled-down model is necessary to verify the performance of the real-size model. This model test method, with criteria that is similar to that of a real turbine, is the most economical and important method. Furthermore, the shapes of the runner and guide vane can be modified or replaced easily. However, during the process of modernization, the components with the spiral casing and draft tube are impossible to repair or replace because of the buried ground. Thus, in this study, numerical analysis is conducted to investigate the hydraulic performance based on the difference between the two-dimensional computer-aided design (CAD) shape and the real three-dimensional scan shape of the spiral casing and draft tube.

A study on the manoeuvrability of T/S SAEBADA by real sea trials (실선시험에 의한 새바다호의 조종 성능에 관한 고찰)

  • An, Young-Su;Kang, Il-Kwon;Kim, Hyung-Seok;Kim, Jung-Chang;Kim, Min-Seok;Jo, Hyo-Jae;Lee, Chun-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.4
    • /
    • pp.289-295
    • /
    • 2005
  • This study is intended to provide navigator with specific information necessary to assist in the avoidance of collision and in operation of ships to evaluate the manoeuvrability of own ship. The actual manoeuvering characteristics of ship can be adequately judged from the results of typical ship trials manoeuvres. Author carried out sea trials based full scale for turning test, zig-zag test, spiral tests and crash-stop test at actual sea going condition. The turning circle manoeuvres were performed on starboard and port sides with $35^{\circ}$ rudder angle at the service speed, and Zig-zag procedures were performed on both sides with $10^{\circ}$ and $20^{\circ}$ rudder angle respectively. Spiral tests were carried out on the both sides and crash stop test was also carried out. The results from tests could be compared directly with the standards of manoeuverability of IMO and consequently the manoeuvring qualities of the ship is fully satisfied with its.

Bond Characteristics of Hybrid Fiber Polymer Reinforcing bars with Different Relative Rib Area (하이브리드 FRP 보강근의 상대 리브면적에 따른 부착 특성)

  • Park Ji Sun;You Young Chan;Park Young Hwan;You Young Jun;Kim Hyeong Yeol;Kim Keung Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.201-204
    • /
    • 2005
  • The bond characteristics of two types hybrid FRP (fiber reinforced polymer) reinforcing bars with different rib geometry were analyzed experimentally. Two types of hybrid FRP. reinforcing bars such as spiral and cross type with different relative rib area were considered in this test. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found' that cross type hybrid FRP reinforcing bars showed the higher bond strength than that of spiral type's due to the higher relative rib area.

  • PDF

Development of new current path pattern of YBCO thin films for Superconducting fault current limiters (초전도 한류기용 YBCO 박막 전류 Path Pattern 개발)

  • Lee B. W.;Kang J. S.;Park K. B.;Oh I. S.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.113-117
    • /
    • 2005
  • In this study, electromagnetic analysis of current paths including meander pattern, spiral pattern, and bi-spiral pattern were performed and in order to verity the analysis results, experiments tests including quench test, and insulation tests were performed. In addition, bubble corner concepts were introduced to enhance insulation reliability. From our study, bi-spiral pattern of YBCO thin films were rather effective for quench and insulation than the other patterns. So this current path pattern was adopted for YBCO thin films in order to develop 6.6 kV resistive fault current limiters. Finally YBCO thin films were connected in series and parallel to enhance capacity, and the test results of current limiting characteristics of 6.6kV resistive SFCL were successful. The Progress in Superconductivity is published every six month and serves as a channel for publications on superconductivity and related topics. The author(s) are required to submit THREE copies of the manuscripts along with original figures directly to the Editor.

  • PDF

Characteristics of Uplift Capacity of a Embedded Foundation and Soil Type (매입기초와 토질에 따른 인발저항력 특성)

  • Lim, SeongYoon;Kim, YuYoung;Yu, SeokChul;Kim, MyeongHwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.23-30
    • /
    • 2019
  • In this study, we evaluated the applicability of proper embedded depth of fillings by examining the uplift resistance using spiral foundation and top base foundation. As a result of the model test, the maximum uplift resistance increased with the embedded depth. The maximum uplift resistance of each region was found to be 50cm depth. The spiral foundation was 335.14N of Sancheong, 312.32N of Seongju, 403.94N of Wanju, and the top base foundation was 745.06N of Sancheong, 1028.82N of Seongju and 950.76N of Wanju. The yield point after the elastic section in the stress-displacement graph of the top base foundation was calculated as the maximum uplift resistance. For this reason, farmers do not actually use top bases foundation. Therefore, it was considered that the additional load increase due to slip connector will not occur. Model test results show that the maximum uplift resistance increases with the purlinss installed under the ground. Therefore, additional comparative studies through purlins installation will be needed.

A Study on the Supporting Effect of a Spiral Bolt as a Support System (Spiral bolt의 지보효과에 관한 연구)

  • Cho, Young-Dong;Kang, Choo-Won;Kim, Jae-Woong
    • Tunnel and Underground Space
    • /
    • v.20 no.5
    • /
    • pp.332-343
    • /
    • 2010
  • This study aims to evaluate the supporting effect of a spiral bolt that is superior to a rock bolt in terms of constructability, stability, environmental and economic aspects as a support system. This study thus analyzed the mechanical properties of a rock bolt which is widely used as a support and a spiral bolt. In addition, laboratory pull-out tests were conducted for the evaluation of properties of the supports such as displacement, pull-out load, confining pressure etc. Moreover, the differences between a rock bolt and a spiral bolt were drawn by comparing the two results of laboratory pull-out tests and in-situ pull-out tests. Then, the differences of the supporting effect of the two supports were analysed by comparing the results of the two pull-out tests with a numerical analysis using FLAC3D.

The Effect of Trunk Stabilization Posture Wearing Spiral Elastic Band on Upper Extremity Function in Stroke Patients (나선형 탄력밴드를 착용한 몸통 안정화 자세가 뇌졸중 환자의 팔 기능에 미치는 효과)

  • Kim, Min-Ho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.2
    • /
    • pp.93-103
    • /
    • 2021
  • Purpose : This study aimed to investigate the effect of trunk postural stability maintained wearing a spiral elastic band on the upper extremity function of patients with stroke who undertook a functional activity program and to provide fundamental data useful for the application of therapeutic interventions in the clinical environment of occupational therapy. Methods : The research subjects included 16 patients with stroke who were evenly divided into an experimental group and a control group. The eight-week intervention consisted of a functional activity program aimed at improving the function of the affected-side upper extremity. The experimental group performed the functional activity program while maintaining a stable trunk posture by wearing a spiral elastic band. The control group followed the program without wearing the band. Upper extremity function was assessed before and after the intervention using a manual function test (MFT) and a motor activity log (MAL), and the effectiveness on the upper extremity function of the affected side was confirmed. Results : First, in the within-group comparison of the upper extremity function scores before and after the intervention, the experimental group showed a statistically significant difference in the MFT and MAL assessment(p<.05). The control group showed a statistically significant difference in the MAL assessment(p<.05). Second, in the between-group comparison of the change in scores after the intervention, a statistically significant difference was observed between the two groups in all assessments(p<.05). Conclusion : This study confirmed the positive effect on upper extremity function of trunk stabilization posture using a spiral elastic band. The results could be useful when implementing a task-oriented training program in the clinical environment of occupational therapy in the future, as application of the training while maintaining trunk postural stability by wearing a spiral elastic band could be more effective for improving the upper extremity function of patients with stroke.

A Study on Seismic Capacity of Circular Spiral Reinforced Concrete Bridge Piers used in High Strength Concrete (고강도 원형나선철근기둥의 내진성능에 관한 연구)

  • 김광수;김민구;배성용;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.547-552
    • /
    • 2001
  • This research was conducted to investigate the seismic behavior and capacity assessment of circular spiral reinforcement concrete bridge piers used in high strength concrete. The displacement ductility, response modification factor(R), effective stiffness and plastic hinge region etc. was used to assess the seismic behavior and capacity of circular spiral reinforcement concrete bridge piers. The experimental variables of bridge piers test consisted of amount and spacing, different axial load levels. From the quasi-static tests on 9 bridge piers and analysis, it is found that current seismic design code specification of transverse confinement steel requirements and details may be revised.

  • PDF

Evaluation of Thermal Fluid Characteristics for EGR Cooler with Spiral Type (Spiral 구조 EGR Cooler의 열유동 특성 평가)

  • 허형석;원종필;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.44-50
    • /
    • 2003
  • Cooled EGR is an effective method for the reduction of NOx from a diesel engine and an EGR Cooler is the key component of the system. High efficiency, low pressure loss and compactness are required for the EGR Cooler. To meet these requirements, new geometric tube must be developed. In this paper, a full size EGR cooler test bench has been developed to validate the CFD flow and heat transfer models. Fluid temperature and pressure drop measurements are provided. fillet temperature is $200^{\circ}C$ and $300^{\circ}C$, and flow rates vary from 0.008 kg/sec to 0.019 kg/sec. The gas flow and heat transfer in a single tube cooler have been studied using computational fluid dynamics(CFD). Analysis has been carried out in a single tube with a plain tube and six spirally enhanced tubes of varying pitch to depth ratio(p/e).