• Title/Summary/Keyword: Spiral test

Search Result 193, Processing Time 0.022 seconds

Performance Evaluation of Long Span Bridge Columns Strengthened with High-Performance Glass Fiber (고성능 유리섬유로 보강된 해상장대교량 교각의 보강성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok;Lee, Jae-Uk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.125-133
    • /
    • 2010
  • Researches and studies which have been conducted so far on external confinement of long span concrete columns have mainly concentrated on concentric loading. But, long span bridge concrete columns over the sea are mainly subjected to concentrated axial load, and at the same time lange amount of moment by eccentric load. This paper experimentally investigates the performance of externally confined high-strength concrete columns subjected to loading mechanism and evaluates the effectiveness of two confinement materials carbon fibre and high performance glass fibre. Twelve short columns with the same dimensions were cast and tested Six columns were reinforced with hoop bars, the remaining six columns were reinforced with spiral bars and wrapped with three layers of carbon failure and high performance glass FRP sheets. Test variables considered were the shape of internal reinforcement and strengthening materials according to loading location. The experimental results showed that eccentric load could obviously lower down the maximum failure load of FRP-confined concrete columns, compared with the columns under concentric load. And compared with the carbon FRP-confined reinforced concrete columns, high performance glass FRP-confined columns displayed a higher load capacity and ductility, when tested both concentrically and eccentrically.

Effects of the PNF Leg Pattern according to Chain Exercise Postures and Resistance Intensity on the Contralateral Leg's Muscle Activity (사슬운동자세와 저항강도에 따른 PNF 다리패턴이 반대측 다리의 근활성도에 미치는 영향)

  • Seok, Him;Yoon, Sung-Young;Heo, Jae-Seok;Lee, Sang-Yeol
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.423-433
    • /
    • 2021
  • Purpose: Proprioceptive neuromuscular facilitation (PNF) is a method for promoting functional movements by facilitating neuromuscular responses through the stimulation of proprioceptors in the body using spiral and diagonal patterns. Irradiation, a basic principle of PNF, is a phenomenon in which the muscle activity of a body part caused by resistance is increased or spread into muscles in other parts via their connected muscles. Resistance training can be divided by body alignment into closed and open chain exercises. Methods: In this study, 19 healthy men in their 20s and 30s were selected as subjects. They performed PNF hip flexion, abduction, and internal rotation motions on their dominant side in an open chain exercise posture in which the nondominant sole was away from the wall, and in a closed chain exercise posture in which the sole was fixed to the wall. The nondominant leg's muscle activity was measured while resistance was maintained with applied pressure at 0%, 25%, 50%, 75%, and 100% of the maximum muscle strength in the last range of motions. A two-way analysis of variance (ANOVA) was conducted for a comparative analysis of the contralateral leg's muscle activity according to the chain exercise postures and the intensity of resistance intensity during PNF hip flexion, abduction, and internal rotation. In addition, an independent sample T-test was conducted for a comparative analysis of each chain exercise posture according to the intensity of resistance. A one-way ANOVA and a Scheffe post-hoc test were also performed to analyze the contralateral leg's muscle activity according to the intensity of resistance in the closed and open chain exercise postures. Results: Results of the two-way ANOVA found that the gluteus medius and the biceps femoris had statistically significant differences in both the chain exercise postures and resistance intensity (p<0.05), and that the vastus medialis and the gastrocnemius did not exhibit statistically significant differences in the chain exercise postures (p>0.05) but showed statistically significant differences in resistance intensity (p<0.05). As a result of the independent sample T-test, the application of the PNF hip flexion-abduction-internal rotation pattern led to a statistically significant difference in the contralateral gluteus medius during the closed chain exercise posture (p<0.05). According to the results of the one-way ANOVA and the Scheffe post-analysis, statistically significant differences were observed in the gluteus medius at 50%, biceps femoris at 75%, vastus medialis at 100%, and gastrocnemius at 100% during the closed chain exercise posture based on a resistance intensity of 0% (p<0.05). In the open chain exercise posture, statistically significant differences were found in the gluteus medius at 50%, biceps femoris at 50%, and vastus medialis at 75% based on the resistance intensity of 0% (p<0.05). In the same posture, there was no significant difference in the gastrocnemius's resistance intensity (p>0.05). Conclusion: When the PNF leg pattern is applied, each muscle requires effective chain exercise postures and resistance intensity to generate the contralateral leg muscle's irradiation.

Development and Usefulness of Acrylic Needle for Percutaneous Bone Biopsy (경피적 골생검용 아크릴 바늘의 제작과 유용성)

  • Kim, Tae-Hyung;Shin, Myung-Jin;Shin, Ji-Hoon;Lim, Jin-Oh;Ryu, Ji-Yeon;Oh, Jae-Seon;Woo, Chul-Woong;Nam, Jeung-Hee
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.25-29
    • /
    • 2010
  • To evaluate the usefulness of newly designed percutaneous bone biopsy needle for pumpkin's specimen collection. We manufactured three types of biopsy needle with different internal processing which were made of 10 mm-diameter acrylic material. We made the conventional type (Ct) similar to the clinical type then compared the test group. The type a (Ta) made 1 cm-length internal processing from the distal, type b (Tb) made taper, and type c (Tc) made internal processing like spiral configuration. We performed 20 times biopsy to get an 10 mm length specimen from pumpkin's surface and evaluated the success rate of the biopsy, length of the specimen, and determine internal processing type of the most suitable biopsy needle (ANOVA test). Success rates of Ct, Ta, Tb, and Tc were 55%, 80%, 90%, and 100%, respectively. The lengths of the specimen of Ct, Ta, Tb, and Tc were $5.6{\pm}1.1\;mm$, $5.9{\pm}0.87\;mm$, $3.9{\pm}0.77\;mm$, and $9.4{\pm}0.54\;mm$, respectively. All groups were statistically significant (p < 0.05) except the group between Ct and Ta (p = 0.28). Newly designed bone biopsy needle seems to be useful for obtaining enough specimen. Tc may be more effective than other types.