• Title/Summary/Keyword: Spiral Scan

Search Result 46, Processing Time 0.03 seconds

Reconstruction Algorithms for Spiral-scan Echo Planar Imaging (Spiral scan 초고속 자기공명영상 재구성 알고리즘)

  • Ahn, C.B.;Kim, C.Y.;Park, D.J.;Kim, H.J.;Ryu, Y.S.;Yi, Y.;Oh, C.H.;Lee, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.157-160
    • /
    • 1996
  • In this paper, reconstruction algorithms of spiral scan imaging which has been used for ultra fast magnetic resonance imaging have been reviewed, and some simulation results using two different algorithms are reported. Since the trajectory of the spiral scan in k-space is the spiral, reconstruction of the spiral scan is not as straight forward as that used in Fourier imaging technique where the sampling points are usually on the rectangular grids. Originally the reconstruction of the spiral scan imaging was based on the convolution backprojection algorithm modified with a shift term, however, some other reconstruction techniques have also been tried by remapping sampling points from spiral trajectory to Cartesian grids. Some experimental aspects of MR spiral scan imaging will also be addressed.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

초고속 자기 공명 영상 기법 - Echo Planar 영상 및 Spiral Scan 영상

  • 안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.6-12
    • /
    • 1999
  • Echo Planar Imaging (EPI) Spiral Scan 영상을 초고속 자기공명영상 기법으로서 전체 k-space의 데이터를 한번 scan에 다 받을 수 있기 때문에 데이터 측정시간을 100ms 이내로 단축시킬 수 있다. 이러한 초고속 영상 기법은 최근 활발히 연구되고 있는 뇌기능 영상과 관련하여 중요도가 더욱 커지고 있다. EPI는 직각좌표계에서 데이터를 받기 때문에 재구성은 비교적 쉬우나 eddy current를 많이 야기시키는 단점을 가지고 있다. 반면에 Spiral Scan 영상은 먼저 데이터를 원 또는 직각좌표계로 interpolation을 한 후 재구성하여야 하는 단점이 있으나, 상대적으로 eddy current가 작고, 방향과 무관하게 균일한 point spread function을 가지며, 혈류와 관련한 위상이 스스로 rephasing 되어 심장 영상 등에 유리한 장점이 있다.

  • PDF

Improved Reconstruction Algorithm for Spiral Scan Fast MR Imaging with DC offset Correction (DC offset을 보정한 나선 주사 초고속 자기공명영상의 재구성 알고리즘)

  • 안창범;김휴정
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.243-250
    • /
    • 1998
  • Reconstruction aspects of spiral scan imaging for ultra fast magnetic resonance imagine(MRI) have been investigated with polar and rectangular coordinates-based reconstruction. For the reconstruction of the spiral scan imaging, acquired data in spiral trjectory should be converted to polar or rectangular grids, where interpolation techniques are used. Various reconstruction algorithms for spiral scan imaging are tested, and reconstructed image qualities are compared with computed phantom. An improved reconstruction algorithm with dc-offset correction in projection domain is proposed, which provides the best reconstructed image quality from the simulation. Image artifact with existing algorithms is completely removed with the proposed method.

  • PDF

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

Interleaved Spiral Scan Imaging (Interleaved 나선 주사 영상)

  • Ahn, C.B.;Kim, H.J.;Shin, J.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.98-99
    • /
    • 1998
  • In this paper, an interleaved spiral scan imaging is investigated for an ultra fast MR imaging. The interleaved spiral technique has relative advantage over single shot spiral imaging with improved resolution and less inhomogeneity-related artifact. An improved reconstruction algorithm is devised with DC-offset correction. Some preliminary experimental results are shown at 1.0 Tesla and 3.0 Tesla whole body MRI system.

  • PDF

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

Eddy current compensation using a gradient system modeling in MR Spiral scan imaging (MR Spiral scan 영상에서 Gradient system의 모델링을 이용한 Eddy current compensation)

  • Cho, S.H.;Kim, P.K.;Kang, S.W.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.339-340
    • /
    • 2007
  • Gradient system에 spiral waveform 입력을 가하면 Hardware limitation에 의하여 만들어지는 gradient fields에 Transient time delay가 발생한다. 이를 보상하기 위하여, Gradient system을 R-L-C 회로로 모델링하여 재구성에 필요한 k-space trajectory를 보정하여 개선된 image를 획득하였다.

  • PDF

Higher Order Shimming for Spiral Scan image (초고속 나선 주사 영상을 위한 고차 Shimming)

  • Kim, Pan-Ki;Jeon, Su-Yeol;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.341-342
    • /
    • 2007
  • 3T MRI system에서 고해상도 영상을 얻기 위해서는 magnetic field를 균일하게 만들어야 한다. 특히 초고속 영상 기법인 Spiral scan 방식과 EPI scan 방식에서는 이미지 영역에서의 magnetic field의 inhomogeneity에 의해 영상의 왜곡이 심해진다. 본 논문에서는 magnetic field의 inhomogeneity를 단시간 내에 측정하기 위해 fast spin echo방식의 pulse sequence 제안하고, magnetic field를 분석하기 위한 field map의 구성과, field pattern의 효과적인 분석을 통하여, magnetic field를 균일하게 만드는 방법을 제안한다.

  • PDF

INITIAL ACQUISITION PROCEDURE FOR KOMPSAT2 WITH K13ANTENNA

  • Lee Jeong-bae;Yang Hyung-mo;Ahn Sang-il;Kim Eun-kyou
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.501-504
    • /
    • 2005
  • In general, most incomplete communication link setup between satellite and ground station right after separation from launcher come from less accurate orbital vector ground station uses to track the satellite because only predicted orbital state vector is available during first few orbits. This paper describes the developed procedure for successful initial acquisition for KOMPSAT-2 using scanning functions ofK13 antenna system with predicted orbital information. Azimuth scan, raster scan, spiral scan functions were tested with KOMPSA Tl under intentionally degraded orbital information for antenna operation. Through tests, spiral scan function was decided to be best search scan among 3 scans. Developed procedure can assure the successful acquisition only if azimuth offset and time offset value are within +/-2deg and +/-30sec, respectively.

  • PDF