• 제목/요약/키워드: Spiral CT

검색결과 87건 처리시간 0.028초

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

상부기도병변의 평가에 있어 나선식컴퓨터단층촬영술을 이용한 3차원적 영상의 유용성 (The Usefulness of Three-Dimensional Imaging with Spiral CT for Evaluation of the Upper Airway Lesions)

  • 김진환;김현웅;소상훈;노영수;임현준;윤대영
    • 대한기관식도과학회지
    • /
    • 제4권1호
    • /
    • pp.43-51
    • /
    • 1998
  • Background: Three-dementional imaging with spiral CT(3D spiral CT) is a well established imaging modality which has been investigated in various clinical settings. However the 3D spiral CT in upper airway disease is rarely reported and its results are still obscure. Objectives: To access the usefulness of 3D spiral CT imaging in patients with upper airway diseases. Materials and Methods We performed 3D spiral CT in fourteen patients In whom upper airway diseases were clinically suspected. Nine of these patients had upper airway stenosis, two had laryngeal cartilage fracture, and three had laryngo-hypopharyngeal cancer. For evaluation of location and extent of the lesions, we compared the findings of 3D imaging with those of air tracheogram, conventional 2D CT images, endoscopic and operative findings. Results: In case of stenosis, 3D spiral CT provide significant useful information, particularly the site and length of the stenotic segment. But, it was difficult to define the fracture of the laryngeal framework and to detect the cartilagenous invasion by head and neck cancer using the 3D imaging. Conclusion : The 3D spiral CT was an useful adjunctive method to assess some kind of upper airway disease but not in others. So, we should compare the findings of 3D images with those of other diagnostic tools for accurate diagnosis of the upper airway disease.

  • PDF

폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교) (The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan))

  • 고재현;오은영;박정호;박상준;윤정환;박정웅;서지영;정만표;이경수;권오정;이종헌
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권4호
    • /
    • pp.564-573
    • /
    • 1999
  • 배 경: 폐색전증의 임상증상은 비특이적이어서 임상증상 만으로 진단이 어렵다. 폐색전증의 진단을 위하여 폐환기관류주사가 선별검사로 널리 사용되고 있으나 PIOPED(the prospective investigation of pulmonary embolism diagnosis) 연구의 결과처럼 저 중등도 확률 소견일 경우 폐색전증의 진단을 내리거나 배제하는데 도움이 되지 않으며 PIOPED 연구의 약 60%의 환자가 저 중등도 확률 소견을 보인다. 이러한 환자들은 확진을 위해 폐동맥조영술이 필요하지만 침습적이며 쉽게 시행할 수 없다는 단점이 있다. 최근 가공 영상을 줄이고 조영제 일시주사 기술로 혈관구조를 조영할 수 있게 한 spiral CT가 폐동맥조영술을 대신하여 폐색전증의 진단에 이용하는 전향적 연구가 이루어지고 있다. 이에 저자들은 폐색전증의 진단에서 spiral CT의 유용성을 알아보고자 폐색전증을 의심하여 spiral CT를 찍은 환자를 대상으로 후향적 조사를 시행하였다. 방 법: 1994년 10월부터 1997년 2월까지 삼성서울병원에 입원한 환자 중 폐색전증이 의심되어 spiral CT를 시행한 20명(남자 : 13명, 여자 : 7명, 평균연령 : 58세)을 대상으로 하였다. 폐색전증의 위험인자로 심부정맥혈전증과 고령이 가장 많았고 폐색전증이 의심된 임상증상으로 갑자기 발생하였거나 악화된 호흡곤란이 가장 많았다. 결 과: 20명의 환자 중 spiral CT로 폐색전증으로 진단된 환자는 16명이었고 3명은 각각 폐암, 폐기종 환자에서 발생한 폐농양을 동반한 폐렴, 울혈성 심부전에 의한 흉막삼출증으로 색전을 확인할 수 없었다. 나머지 1명은 spiral CT에서 정상 소견이었다. 폐환기관류주사에서 고확률로 판정된 12명의 환자중 1명에서 spiral CT로 폐기종 환자에서 발생한 폐농양을 동반한 폐렴인 위양성으로 진단할 수 있었다. 폐환기관류주사에서 저 중동도 확률을 보이는 4명 중 3명에서 spiral CT로 폐색전증을 진단할 수 있었다. 야간, 기계호흡 등의 이유로 폐환기관류주사를 시행치 못한 3명에서 spiral CT로 폐색전증을 진단 또는 배제할수 있었다. 폐색전증으로 진단된 16명 중에서 폐엽동맥 수준 이상의 색전은 11례 였으며 분절하동맥 수준 이하의 색전 경우는 5례였다. 결 론: 이상의 결과로 spiral CT는 폐분절동맥까지의 폐색전증의 진단에 유용하며, 특히 중심성 폐색전증의 확진과 배제에 있어서 중요한 진단방법이라고 생각된다. 향후 폐색전증의 진단에 spiral CT가 진단과정에 도입될 수 있는지에 대한 대규모의 전향적인 연구가 필요할 것으로 사료된다.

  • PDF

Spiral CT를 이용한 경동맥 질환의 평가 (The Evaluation of Carotid Artery Stenosis Using Spiral CT.)

  • 윤희석;황윤천;신현길;백천기;윤석민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권2호
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

Spiral CT의 고속 영상재구성 알고리즘에 관한 연구 (A Study on the Fast Image Reconstruction Algorithm for Spiral CT)

  • 허창원;진승오;이재덕;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교 (Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.154-161
    • /
    • 1997
  • 목적: 횡격막 파열은 그 진단이 어렵고 지연되는 경우가 많으며, 진단이 늦어지면 유병율과 사망율이 높아지므로 조기진다는 매우 중요하다. 저자들은 최근 많이 이용되는 영상진단법인 나선형 CT와 자기공명영상, 그리고 초음파건사중 어떤 방법이 가장 예민하고 정확한 진단방법인지 동물실험 모델을 통하여 평가하고자 하였다. 대상 및 방법: 토끼에서 인위적으로 횡격막파열을 대, 중, 소로 만든 후 1일, 3일, 7일째 나선형 CT와 자기공명영상, 그리고 초음파검사를 동시에 시행하였다. 결과: 횡격막파열의 진단 민감도와 특이도는 초음파검사가 94.4%와 92.9%, 자기 공명영상이 54.0%와 85.75, 나선형 CT가 46.0%와 78.6%이었다. 횡격막 파열의 진단은 초음파검사, 자기공명영상, 나선형 CT순으로 정확하였으며 초음파 검사가 자기공명영상이나 나선형 CT보다 유의하게 우월하였고(P<0.05), 자기공명영상과 나선형 CT는 유의한 차이가 없었다. 초음파검사는 파열의 크기와 상관없이 횡격막파열의 구별이 용이하였고 자기공명영상과 나선형 CT는 파열의 크기가 클수록 횡격막파열의 구별이 용이하였으나 통계적으로 유의한 차이는 없었다(P>0.05). 수술후 1일에는 전예에서 늑막삼출액이나 혈흉을 동반하였다. 이때에는 초음파나 자기공명영상이 나선형 CT에 비해 우월하였다. 시간경과에 따랄 초음파검사와 자기공명영상은 진단율이 상대적으로 저하되었으나 통게적으로 유의한 차이는 없었다(P>0.05) 탈장을 동반한 경우에는 진단의 민감도가 자기공명영상, 나선형 CT, 초음파검사순으로 높았으며 초음파검사가 상대적으로 낮았다. 그러나 통계적으로 유의한 차이는 없었다(P>0.05). 결론: 초음파검사가 횡격막파열의 진단에 가장 유용한 것으로 밝혀졌으며, 이러한 결과는 앞으로 임상에 적용하여 검증되어야 할 필요가 있다고 생각된다.

  • PDF

축방향 CT 스캔과 나선형 CT 스캔에서 영·유아의 장기흡수선량 비교 평가 (A Comparative Evaluation of Organ Doses in Infants and toddlers between Axial and Spiral CT Scanning)

  • 김상태;은성종;김성길
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 성인에 비해 방사선에 민감하고 검사건수가 증가하고 있는 영 유아의 CT 스캔 시의 장기흡수선량을 평가하기 위해 스캔부위를 머리부위와 가슴부위로 구분하고 64 MDCT를 이용하여 축방향 스캔과 나선형 스캔으로 비교했다. 스캔부위에 상관없이 나선형 스캔 시의 선량이 축방향 스캔 시 보다 유의하게 낮은 것으로 나타났다. 축방향 스캔과 비교해서 나선형 스캔 중 피치 1.355를 사용했을 때가 나머지 두 피치(0.525, 0.988)를 사용했을 때보다 가슴부위 스캔의 평균 장기흡수선량이 유의하게 높게(평균 -12.03%) 나왔다. 나선형 스캔 시 장기흡수선량이 축방향 스캔보다 평균 20.54% 낮게 나왔다. 결과적으로 인체모형을 통한 장기흡수선량을 평가한 본 연구는 몬테카를로 시뮬레이션 결과값을 실증하고, CT 검사를 받는 영 유아의 장기흡수선량의 보다 정확한 평가에 기여할 것이다.

폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성 (The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism)

  • 김우규;임병성;김미영;황홍곤
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.669-680
    • /
    • 1999
  • 연구배경: 폐색전증은 조기진단으로 신속한 치료를 요하는 치명적인 질환으로 관심여부에 따라서는 비슷한 조건의 병원규모라 하더라도 진단율이 상이한 차이를 나타내는 것으로 알려져있다. 폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술은 높은 민감도와 특이도를 나타낸다고 알려져있다. 저자들은 폐색전증에서 나선식 전산화 단층촬영 혈관조영술의 2, 3차원 영상소견과 진단적 가치를 평가하였고, 나선식 전산화 단층촬영 혈관조영술과 폐관류 스캔을 비교하였다. 방 법: 1997년 9월에서부터 1998년 8월까지 20명의 환자에서 나선식 전산화 단층촬영 혈관조영술을 시행하였고, 이 중 14명의 환자에서 폐관류 스캔을 동시에 시행하여 그 임상적 기록과 함께 분석하였다. 또한 색전의 위치에 따른 혈관 분포 및 동반된 폐실질의 변화를 분석하였다. 결 과: 폐색전증의 색전의 위치에 따른 분포양상을 보면, 좌측 혜(n=103) 보다 우측 폐(n=129)에, 좌 우측폐의 상엽과 중엽을 합친 것(n=101)보다 하엽(n=116)에 많은 빈도를 보였고, 세분절이하로 갈수록 많은 빈도를 보이는데 하엽에서는 5 번째에서 감소되는데, 이것은 세분절이하 혈관 색전에서 나선식 전산화 단층촬영 혈관조영술의 낮은 발견율 및 동반된 폐경색과 무기폐 등이 주로 하엽에 생기기 때문에 가려진 것으로 생각된다. 나선식 전산화 단층촬영 혈관조영술로 폐색전증 진단시, 1명에서 위음성을 보여 95%(19명/20명)의 발견율을 보였고, 급성 및 만성 소견이 각각 16명, 3명이었고, 폐경색, 무기폐, 흉막삼출이 각각 9명(45%), 4명(20%), 6명(30%)이었다. 결 론: 2, 3차원 영상이 포함된 나선식 전산화 단층촬영 혈관조영술은 폐색전증에서 비침습적인 진단 방법으로 1) 폐실질을 포함하여 색전의 전체적 분포를 용이하게 알 수 있으며, 2) 진단시 높은 발견율을 보이며, 3) 비교적 급성과 만성의 구분이 되고, 4) 동반된 폐실질의 변화와 흉막삼출을 보는데 유용한 진단방법이며, 5) 폐관류 스캔 소견과 높은 연관성을 보였다. 제한점으로는 세분절이하에서 인지 장애(perception error)가 있다. 또한, 만성 폐쇄성 폐질환, 천식, 결핵 등이 동반된 호흡기 질환에서는 색전이 나선식 전산화 단층촬영 혈관조영술에서 간과(missing) 될 수 있다.

  • PDF

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • 제48권4호
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.