• Title/Summary/Keyword: Spine position

Search Result 251, Processing Time 0.022 seconds

Reliability and Convergent Validity of Standing Posture Measurement Using a Mobile Application in Forward Head Posture (전방머리자세 성인을 대상으로 모바일 어플리케이션을 이용한 자세정렬 측정의 신뢰도 및 수렴 타당도 연구)

  • Kang, Hyojeong;Kim, Minkyu;Yang, Hoesong;Lee, Wanhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • Purpose : The aim of this study was to assess the intra- and inter-rater reliability and validity of measurements of head, neck, and pelvis posture using a mobile application in subjects with forward head posture. Methods : Forty-eight volunteers (22 men, 26 women) participated in this study. Two raters independently examined whole body picture images in a lateral standing posture with arms crossed using a CA-Smart Posture Reminder (CA-SPR), and a rater took and calculated posture images twice to assess reliability. We measured five parameters: craniovertebral angle 1 (CVA1), anterior shoulder translation (AST), pelvic tilt (PT), knee angle (KA), and ankle angle (AA) in the subject's sagittal plane using CA-SPR. We examined whole spine X-ray images in the same position to assess validity. We measured four variables in the subjects: CVA2, translation distance (AHT), anterior pelvic plane (APP), and sacral slope (SS). The intra- and inter-rater reliability were calculated using the intraclass correlation coefficient (ICC). Convergent validity was calculated using Pearson's correlation coefficient. Results : The intra-rater reliability (ICC=.889 -.989) and inter-rater reliability (ICC=.800 -.980) were excellent for all variables measured using CA-SPR. The variables measured using CA-SPR and X-ray were significantly positively correlated (r=.623, p<.01). However, the correlation of the variables in the pelvis was not statistically significant. Conclusion : This study shows that a mobile application (CA-SPR) is a useful tool for measuring head and neck posture in subjects with forward head posture. However, further study is needed to measure pelvic variables when using a mobile application.

Intrarater and Interrater Reliability of the Lateral Scapular Slide Test in Patients with Chronic Shoulder Pain (만성 견부통 환자를 대상으로 한 측방 견갑골 활주 검사의 측정자내 및 측정자간 신뢰도)

  • Park, Young-Seok;Kim, Suhn-Yeop;Seo, Young-Joo;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.32-40
    • /
    • 2009
  • Purpose: The purposes of this study were to determine the intertester and intratester reliabilities of the Lateral Scapular Slide Test (LSST) method, and to examine if significant differences existed in scapular positions among the pain groups (right-shoulder pain group, left-shoulder, pain group and both-shoulders pain group). 27 female subjects (mean age = 51.6, mean height = 157.7 cm, mean weight = 57.5 kg) with shoulder pain were recruited for this study. Methods: The bilateral distances between the root of the scapular spine and T3/4 (RSS), and between the inferior scapular angle and T7/8 (IA), were recorded. Subjects were tested at three positions: the with arms with abducted at 0, 45 and 90 degrees in the coronal plane. The LSST measurements were performed by two testers, selected randomly. Results: The results were as follows: Intraclass correlation coefficients (ICCs) for the intertester reliability were excellent (ICC 0.78-0.94). And the ICCs for the intratester reliability were excellent (ICC 0.83-0.99). In the right-shoulder and both-shoulders pain groups, the right-side RSS and IA values of right side were significantly greater than of the left-side RSS values left side for the arms abducted at 0 degrees of right shoulder pain group and both shoulder pain group (p<.05). However, the side-to-side difference was less than 1.5 cm. Conclusion: Our results suggest that the LSST is highly reliable in identifying the abnormal scapular position of patients with shoulder problems. Future research should be continued to clarify the clinical usefulness of this method.

  • PDF

A Proposal for Applying an Onsite Exercise Program for the Prevention of Work-Related Chronic Back Pain in the Automobile Manufacturing Field (자동차 제조업 장의 작업 관련성 만성 허리통증 예방을 위한 현장적용 운동프로그램 제안)

  • Kim, Seong-Su;Lee, Eun-Sang;Kim, Young-Ok;Lee, Young-Sin
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Purpose : The purpose of this research was to develop a proposal by investigating the work habits associated with exercise programs for the prevention of chronic back pain. Methods : The symptoms, areas and causes of musculoskeletal patients were analyzed during a three-month period in order to develop and apply prevention programs that stimulate lumbar deep layer muscle movement. Results : The results of this study show that the lumbar and shoulders are primary areas of pain. According to the literature, lumbar and shoulder pain is caused due to long periods in the standing position and unhealthy posture during work. A preliminary program was conducted for one month to study lower back pain prevention. Preliminary results of the program showed a lumbar stabilizing effect caused by the strengthening of abdominal muscles. In addition, the alignment of the spine often leads to effective action. Therefore, action-oriented programs should be implemented in order to induce contractions of the transverse abdominis muscle. Conclusion : The completed program should consider habit and practices of workers within their working environment. The promotion of health through exercise for both employers and workers is expected to bring physical and psychological benefits that will positively affect economic results.

Effects of the Hip Internal Rotation Gait on Gluteal and Erector Spinae Muscle Activity (고관절 내회전 보행이 둔부 근육과 척추 기립근의 근활성도에 미치는 영향)

  • Kwon, Oh-Yun;Won, Jong-Hyuck;Oh, Jae-Seop;Lee, Won-Hwee;Kim, Soo-Jung
    • Physical Therapy Korea
    • /
    • v.13 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • The purpose of this study was to identify the effect of the hip internal rotation on gluteal and erector spinae muscle electromyographic (EMG) activity during treadmill walking. Eleven healthy subjects were recruited. All subjects performed treadmill walking while maintaining the hip in neutral position (condition 1) and in internal rotation (condition 2). Surface EMG activity was recorded from four muscles (gluteus maximus (GM), gluteus medius (GMED), tensor fascia latae (TFL), and erector spinae (ES)) and the hip internal rotation angle was measured using a three dimensional motion analysis system. The gait cycle was determined with two foot switches, and stance phase was normalized as 100% stance phase (SP) for each condition using the MatLab 7.0 program. The normalized EMG activities according to the hip rotation (neutral or internal rotation) were compared using a paired t-test. During the entire SP of treadmill walking, the EMG activities of GM in condition 1 were significantly greater than in condition 2 (p<.05). The EMG activities of TFL and ES in condition 2 were significantly greater than in condition 1 (p<.05). The EMG activities of the GMED in condition 1 were significantly greater than in condition 1 (p>.05) except for 80~100% SP. Further studies need randomized control trials regarding the effect of hip internal rotation on the hip and lumbar spine muscle activity. Kinetic variables during gait or going up and down stairs are also needed.

  • PDF

Cervical Open-Door Laminoplasty by Hydroxyapatite Implant Insertion Without Suturing

  • Kawanabe, Yoshifumi;Fujimoto, Motoaki;Sato, Tsukasa
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.362-367
    • /
    • 2018
  • Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.

Correlation of Radiographic and Patient Assessment of Spine Following Correction of Nonstructural Component in Juvenile Idiopathic Scoliosis

  • Lee, Jin Gyeong;Yun, Young Cheol;Jo, Won Jae;Seog, Tae Yong;Yoon, Yong-Soon
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.863-871
    • /
    • 2018
  • Objective To evaluate the association between progression of curvature of scoliosis, and correction for functional component in patients with juvenile idiopathic scoliosis (JIS). Methods We retrospectively reviewed medical data of patients prescribed custom molded foot orthosis (FO) to correct inequality of RCSPA (resting calcaneal stance position angle), and chose 52 patients (26 females, 26 males) with Cobb angle ${\geq}10^{\circ}$ in radiology and uneven pelvic level at iliac crest by different RCSPA (${\geq}3^{\circ}$) as a factor of functional scoliosis. They had different hump angle ${\geq}5^{\circ}$ in forward bending test, for idiopathic scoliosis component. Their mean age and mean period of wearing FO were $79.5{\pm}10.6months$ and $18.6{\pm}0.70months$. Results Cobb angle was reduced from $22.03^{\circ}{\pm}4.39^{\circ}$ initially to $18.86^{\circ}{\pm}7.53^{\circ}$ after wearing FO. Pelvis height difference and RCSPA difference, were reduced from $1.07{\pm}0.25cm$ initially to $0.60{\pm}0.36$, and from $4.25^{\circ}{\pm}0.71^{\circ}$ initially to $1.71^{\circ}{\pm}0.75^{\circ}$ (p<0.01). Cobb angle improved most in 9 months. However, there was no significant improvement for those with more than $25^{\circ}$ of Cobb angle initially. Mean Cobb angle improved in all age groups, but patients less than 6 years had clinically significant improvement of more than $5^{\circ}$. Conclusion JIS can have functional components, which should be identified and managed. Foot orthosis is useful in correcting functional factors, in the case of pelvic inequality caused by different RCSPA, for patients with juvenile idiopathic scoliosis.

The effect of sacroiliac joint manual therapy on heart rate variability in women with primary dysmenorrhea

  • Park, Sun-Geon;Song, Seong-Hyeok;Jung, Ji-Hye;Joo, Young-Lan;Yang, You-Jin;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.252-260
    • /
    • 2020
  • Objective: Disorder of the autonomic nervous system is considered to be the cause of primary dysmenorrhea. The spine has a close relationship with the autonomic nervous system, and the sacrum is mechanically and neurologically connected to the uterus through ligaments. Therefore, this study was conducted to check the effect on the autonomic nervous system through measurement of heart rate variability by applying manual therapy to the sacroiliac joints of subjects with primary dysmenorrhea and to suggest an effective treatment method for dysmenorrhea. Design: Randomized controlled trial. Methods: Thirty females with dysmenorrhea were assigned to either the manual therapy group and sham treatment group according to the random treatment method. The manual therapy was applied to the sacroiliac joints, and the sham treatment was only treated with the hands placed in the same position of the intervention. Heart rate variability and the Visual Analogue Scale (VAS) were measured on the day when menstruation began ±2. Interventions were performed between the groups, followed by a 5-minute break and then re-measurements were made. Results: There were significant differences in autonomic balance and VAS scores in the manual therapy group before and after the intervention between groups (p<0.05). In the sham treatment group, there were significant differences in low frequency, autonomic balance, and VAS scores (p<0.05). There were significant differences in autonomic balance between groups (p<0.05). Conclusions: In females with primary dysmenorrhea, manual therapy applied to the sacroiliac joint was found to be effective for a short time on autonomic activity.

Comparison of Activity and Use of Hip Abductor Muscle Group According to Range of Motion during the Clam Exercise (클램 운동 시 운동범위에 따른 엉덩관절 벌림근의 활성도와 사용 비교)

  • Choi, Yong-Gil;Lee, Sang-Yeol;Choi, Su-Hong;Yoon, Sung-Young;Kim, In-Gyun
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.341-349
    • /
    • 2022
  • Purpose: The purpose of this study is to compare the muscle activity of the hip abductors and the ratio between the hip abductor muscle group according to the range of hip abduction during the clam exercise. Methods: This study was conducted on 18 healthy men in their aged 20 to 29 who had not been diagnosed with spine-related diseases. The subjects performed a clam exercise without rotation of the pelvis in a state of 60° hip flexion and 90° knee joint flexion in the side-lying position. Using Myomotion equipment and EMG, the muscle activity of the hip abductor muscles and the activity ratio between the hip abductor muscle group were measured during the clam exercise by dividing the range into initial, mid-range, and terminal sections. Repeated measures analysis of variants was employed to compare the activity and use of hip abductor muscles according to range of motion during the clam exercise. Results: Gluteus medius muscle activation was significantly increased in the comparison of muscle activity in the initial, mid-range, and terminal sections of hip abduction. Tensor fasciae latae muscle activation was significantly increased in the comparison of muscle activity in all range of motion sections as well. The gluteus medius-tensor fasciae latae muscle activation ratio was significantly increased in the terminal section compared to the initial section. Conclusion: The gluteus medius and tensor fasciae latae had higher muscle activities as they approached the terminal section during the clam exercise, and the hip abduction activity ratio of the gluteus medius and tensor fasciae latae was higher as the range of motion approached the terminal section.

Posture Correction Guidance System using Arduino (아두이노를 활용한 자세교정 유도 시스템)

  • Kim, Donghyun;Kim, Jeongmin;Bae, Woojin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.369-372
    • /
    • 2021
  • These days, people spend more time sitting at a desk for studies or work. Also, because people continue to use computers, smartphones, and tablet PCs often during break times, their posture is getting worse. Maintaining a position of bad posture for an extended period of time causes problems with the musculoskeletal system related to the neck, shoulders, and spine. Additionally, problems such as physical fatigue and posture deformation are predicted to expand to a wide range of age groups. Therefore, the core function of the system we are developing is to ensure correct sitting posture and to receive alert notifications via the created mobile application. To create the system, a flex sensor, pressure sensor, and tilt sensor are attached to a chair and utilized. The flex sensor detects and compares the amount of bending in the chair's posture and transmits this value to an Arduino Uno R3 board. Additionally, information such as body balance and incline angle are collected to determine whether or not the current sitting posture is correct. When the posture is incorrect, a notification is sent through the mobile application to indicate to the user and the monitoring app that their posture is not correct. The system proposed in this study is expected to be of great help in future posture-related research.

  • PDF

Development of Postural Correction App Service with Body Transformation and Sitting Pressure Measurement (체위 변환과 좌압 측정을 통한 자세교정 앱 서비스의 개발)

  • Jung-Hyeon Choi;Jun-Ho Park;Young-Ki Sung;Jae-Yong Seo;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.1
    • /
    • pp.15-20
    • /
    • 2023
  • In general, maintaining an incorrect sitting posture for a long time is widely known to adversely affect the spine. Recently, several researchers have been interested in the causal relationship between incorrect sitting posture and spinal diseases, and have been studying methods to precisely measure changes in sitting or standing posture to prevent spinal diseases. In previous studies, we have developed a sensor device capable of measuring real-time posture change, applied a momentum calculation algorithm to improve the accuracy of real-time posture change measurement, and verified the accuracy of the postural change measurement sensor. In this study, we developed a posture measurement and analysis device that considers changes in the center of body pressure through the developed sitting pressure measurement, and it confirmed the sensor as an auxiliary tool to increase the accuracy of posture correction training with improving the user's visual feedback.