• Title/Summary/Keyword: Spinal compression fracture

Search Result 59, Processing Time 0.031 seconds

Clinical evaluation of Oriental Medicine treatment of Stable Compression Fracture by D.I.T.I. (D.I.T.I로 본 Stable Compression Fracture의 한의학적 치료효과)

  • Lee, Geon-Mok;Moon, Sung-Jae;Lee, Byung-Chul
    • Journal of Oriental Medical Thermology
    • /
    • v.1 no.1
    • /
    • pp.28-37
    • /
    • 2002
  • Stable Compression Fractures(SCF hereafter) are most often caused by trauma such as traffic accidents. These SCFs usually occur in the thoracic and lumbar regions of the spinal cord. Human life spans have increased as a result of medical advances, which in turn has led to an increase in the elderly population. SCFs are divided into the categories of stable and unstable. The categories are determined through X-rays and P/Ex tests. The D.I.T.I. is then used to diagnose the severity and prognosis of the fracture injuries, and it allows an objective evaluation of the symptoms. This author researched 40 patients who were treated at Wonkwang University Oriental Medical Center from October 1995 to December 1996. The patients were diagnosed by X-ray as having SCFs and treated primarily with acupuncture. Both the changes in D.I.T.I. and patients' self-diagnoses of their conditions before and after treatment yielded the meaningful results which have been presented here. 1. 75% of those who suffer from Stable Compression Fractures are 60 years of older. Of those, the ratio of male to female is 1 to 4. This is due in part to the fact that many elderly women seek Oriental medicine treatment for conditions associated with advanced age. 2. 53.3% of these injuries occurred between T11 and L2. 3. 65% of patients were hospitalized for 10 to 29 days, and then able to be treated on an outpatiens basis. 4. The D.I.T.I. results showed 50% below $0.2^{\circ}C$, 30% between 0.3 and $0.5^{\circ}C$, 10% between 0.5 and $0.7^{\circ}C$, 10% between 0.7 and $0.9^{\circ}C$, and 0% over $0.9^{\circ}C$. 5. The results of treatment using Modified Evaluation System in Thoracolumbar Vertebral Fractures Method showed that 55% of patients achieved excellent recovery and 40% achived good recovery. After comparing the D.I.T.I. results before and after treatment, we found 50% of patients showed excellent recovery $({\Delta}T{\leq}0.2)$ and 40% showed good recovery$(0.2<{\Delta}T{\leq}0.5)$.

  • PDF

Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy

  • Son, Byung-Chul;Kim, Deog-Ryeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.61-64
    • /
    • 2015
  • A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.

Spontaneous Vertebral Reduction during the Procedure of Kyphoplasty in a Patient with Kummell's Disease

  • Hur, Won-Seok;Choi, Sang-Sik;Lee, Mi-Kyoung;Lee, Dong-Kyu;Lee, Jae-Jin;Kim, Kyong-Jong
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.231-234
    • /
    • 2011
  • Kummell's disease is a spinal disorder characterized by delayed post-traumatic collapse of a vertebral body with avascular necrosis. Although definitive treatment for Kummell's disease has not been established, it has been reported that percutaneous vertebroplasty or kyphoplasty has shown good results. However, these procedures are not recommended for severely collapsed vertebral bodies because of the risk of cement leakage or technical difficulties. Authors report a rare case of spontaneous reduction in vertebral height by the insertion of a working cannula into the vertebral body in Kummell's disease.

Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture (흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과)

  • Shim, Byeoung-Su;Kim, Keun-Su;Lee, Jung-Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

Relationship between the Progression of Kyphosis in Thoracolumbar Osteoporotic Vertebral Compression Fractures and Magnetic Resonance Imaging Findings (흉요추 골다공증성 압박 골절에서의 후만 변형의 진행과 자기공명영상 소견 사이의 관계)

  • Jun, Deuk Soo;Baik, Jong-Min;Kwon, Hyuk Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.336-342
    • /
    • 2019
  • Purpose: To examine the relationship between the progression of a kyphotic deformity and the magnetic resonance imaging (MRI) findings in conservatively treated osteoporotic thoracolumbar compression fracture patients. Materials and Methods: This study categorized the patients who underwent conservative treatment among those patients who underwent treatment under the suspicion of a thoracolumbar compression fracture from January 2007 to March 2016. Among them, this retrospective study included eighty-nine patients with osteoporosis and osteopenia with a bone density of less than -2.0 and single vertebral body fracture. This study examined the MRI of anterior longitudinal ligament or posterior longitudinal ligament injury, superior or inferior endplate disruption, superior of inferior intravertebral disc injury, the presence of low signal intensity on T2-weighted images, and bone edema of intravertebral bodies in fractured intravertebral bodies. Results: In cases where the superior endplate was disrupted or the level of bone edema of the intravertebral bodies was high, the kyphotic angle, wedge angle, and anterior vertebral compression showed remarkably progression. In the case of damage to the anterior longitudinal ligament or the superior disc, only the kyphotic angle was markedly prominent. On the T2-weighted images, low signal intensity lesions showed a high wedge angle and high anterior vertebral compression. On the other hand, there were no significant correlations among the posterior longitudinal ligament injury, inferior endplate disruption, inferior disc injury, and the progression of kyphotic deformity and vertebral compression. The risk factors that increase the kyphotic angle by more than 5° include the presence of injuries to the anterior longitudinal ligament, superior endplate disruption, and superior disc injury, and the risk factors were 21.3, 5.1, and 8.5 times higher than those of the uninjured case, and the risk differed according to the level of bone edema. Conclusion: An osteoporotic thoracolumbar compression fracture in osteoporotic or osteopenic patients, anterior longitudinal ligament injury, superior endplate and intravertebral disc injury, and high level of edema in the MRI were critical factors that increases the risk of kyphotic deformity.

Study on the Movement of New Qi-gong "WuQinXi" Exercise for Lumbar Spinal Disease : Based on 10 Mode, 15 Mode, 18 Mode (요추 질환에 대한 신기공 오금희의 동작연구 -10식, 15식, 18식을 중심으로-)

  • You, Kyung Gon;Yeom, Seung Ryong;Lee, Sang Yeong;Kwon, Young Dal;Jeong, Hyun Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.280-288
    • /
    • 2013
  • Hua-Tuo(145-208) created five "WuQinXi" exercise by imitating the movements of a tiger, a deer, a bear, a monkey and a bird. The "WuQinXi" exercise, one of the medical Qi-gongs, is an exercise maximizing human's self healing power and has been effective significantly at several modern researches. There are many exercise therapies in western medcine, such as Willamss flexion exercise, Mckenzie's extension exercise, vertebral stabilization exercise and so on. However, there isn't a special exercise therapy which can be applied for medical practice in oriental medicine. So We selected some motions from "WuQinXi" exercise, which are suitable for lumbar spinal disease, and analyzed them. After that, We assorted them by kinds of lumbar spinal disease. First, We selected 22 motions which are related with lumbar movements from 3 type "WuQinXi" exercises ; 10 mode, 15 mode, 18 mode. And then, We classified them according to lumbar movements as flexion, extention, lateral bending and rotation, and also functions as stabilization and rubbing. Next, with these classifications, We assorted those motions by kinds of lumbar spinal disease as HIVD(herniation of intervertebral disc), spinal stenosis, spondylolysis and spondylolisthesis, facet joint syndrome, compression fracture and spondylosis. We expect that trying "WuQinXi" exercise at clinic in this way, the particular exercise therapy of oriental medicine, "WuQinXi" exercise will become more popular. And Oriental medical doctors will be able to teach patients "WuQinXi" exercise's motions easily at clinic, depending on kinds of lumbar spinal disease each patient suffers from. We plan to study more about 20 mode, 30 mode, 40 mode and the effect of "WuQinXi" exercise by comparing patients who do the "WuQinXi" exercise with the patients who do the western medical exercise therapy.

Cauda Equine Syndrome Induced by Spinal Epidural Hematoma due to a Low-Energy Osteoporotic Vertebral Fracture (저 에너지 손상 골다공증성 척추체 압박골절 이후 지연성으로 발생한 척추 경막외 혈종으로 인한 마미증후군)

  • Hwang, Seok-Ha;Suh, Seung-Pyo;Hong, Sung-Ha;Kim, Joo-Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.187-191
    • /
    • 2019
  • Spinal epidural hematoma (SEH) can occur naturally or traumatically and is most common in patients with an underlying disease of the vascular structure or coagulation disorder. Most SEHs occur naturally for no apparent reason, and epidural hematoma caused by trauma is less common, comprising 1.0%-1.7% of total spinal injuries. Few reports of SEH induced cauda equine syndrome resulting from low-energy injury caused by osteoporotic vertebral compression fractures are available. The authors experienced a case of delayed SEH after hemorrhage due to a low-energy injury in an elderly patient. No cases in Korea have been reported; therefore, this case is reported with a review of the relevant literature.

Diagnosis and treatment of the odontoid process fracture of the axis in a dog (강아지 고리뼈의 치아돌기 골절 진단과 치료)

  • Hyoung Joon Park;ShinHo Lee;Chung Hui Kim;ChungKil Won;Jae-Hyeon Cho
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.1
    • /
    • pp.87-92
    • /
    • 2023
  • A 7-year-old dog weighing 3.9 kg visited the hospital with symptoms of inability to stand and quadriparesis. There were seizure symptoms 2 months before admission to the hospital, and the symptoms of stiffness and rigidity appeared. Radiographs showed normal vertebrae in cervical vertebral column. Magnetic resonance imaging (MRI) and computed tomography (CT) were performed immediately to diagnose vertebral lameness. As a result of the CT, it was possible to observe the fracture of the odontoid process of the axis, and the exact location of the damage was identified. The odontoid process was fractured and separated from the body of the 2nd cervical vertebra (axis), and fragment of the process was observed inside the vertebral arch of the first cervical vertebra (atlas), and the body of the axis was lifted to the dorsal side. The MRI examination reflected the CT findings and confirmed severe spinal cord compression due to the fracture of the odontoid process. The patient was applied by neck brace and medical management including Mycophenolate mofetil administration was performed. The patient was able to move legs and tail after 2 weeks, and was able to voluntarily defecate, urinate and stand up after 4 weeks of administration.

Efficacy and Safety of Balloon Kyphoplasty in the Treatment of Osteoporotic Vertebral Body Compression Fractures : Compared with Vertebroplasty

  • Yi, Won-Jae;Lee, Jung-Ho;Lee, Hyuk-Gee;Ryu, Kee-Young;Kang, Dong-Gee;Kim, Sang-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2007
  • Objective : Kyphoplasty and vertebroplasty are two minimally invasive procedures for osteoporotic vertebral compression fractures. The purpose of this retrospective study was to compare the radiological findings and clinical outcomes between two procedures. Methods : Osteoporotic vertebral fractures were treated in 76 vertebrae, using kyphoplasty (n=35 vertebrae) and using vertebroplasty (n=41 vertebrae). Fractured vertebral bodies were diagnosed by correlating the clinical symptoms with radiologic study. The responses of pain symptoms were measured by a self-reported Visual Analog Scale (VAS) score. Plain X-rays were checked preoperatively and postoperatively at admission and 6 months. The vertebral body height and kyphotic angle were measured to assess the reduction of the sagittal alignment. Results : The mean pain scores were decreased significantly for both procedures postoperatively, but there were no significant differences between two groups. Kyphoplasty led to a significant reduction of the vertebral body height and improvement of kyphotic angle. There were no neurological deficits after kyphoplasty, but one patient experienced paraparesis after vertebroplasty. During the 6 months follow-up both procedures provided stabilization of the sagittal alignment. Conclusion : Kyphoplasty and vertebroplasty are considered effective minimally invasive techniques for the stabilization of osteoporotic vertebral body fractures, leading to a statistically significant reduction in pain. Kyphoplasty significantly restore sagittal alignment. Also, complications and the incidence of bone cement leakage are significantly lesser than vertebroplasty. Therefore, kyphoplasty seems to be reasonable procedure for osteoporotic vertebral body compression fractures when medical treatment fail.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.