• Title/Summary/Keyword: Spin loss

Search Result 109, Processing Time 0.023 seconds

Characteristics of Thin-Film Inductors Using EeZrBAg Magnetic Thin Films (FeZrBAg 자성막을 이용한 박막 인덕터의 임피던스 특성)

  • 송재성;민복기;허정섭;김현식
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.250-255
    • /
    • 2000
  • Double rectangular spiral thin-film inductors were fabricated using $Fe_{86.7}Zr_{3.3}B_{4}Ag_{6}$ thin film with high permeability and resistance, in which easy axis of magnetization of the thin-film was perpendicular or parallel to the current direction. The perpendicular geometry inductor revealed higher inductance than the parallel geometry one, because spin aligns of magnetic film were more easily along the field direction due to higher field intensity in the perpendicular geometry. The increase of the inductance, however, resulted in the decrease of resonance frequency. The permeability was monitored by annealing the thin-films at different temperatures. With increasing the permeability, the inductance increased, but total resistance also increased due to the increase in magnetic core loss. As the resonance frequency was higher in air-core inductor than in magnetic thin-film core inductor, it is suggested to increase the resonance frequency that the characteristic of air-core inductor rather than the magnetic properties of the thin-film should be enhanced..

  • PDF

Improved DNA Extraction Method for Molecular Diagnosis from Smaller numbers of Cells

  • Oh, Seo Young;Han, Jeong Yeon;Lee, So Ra;Lee, Hoon Taek
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.3
    • /
    • pp.99-105
    • /
    • 2014
  • Isolating total DNA from small samples using traditional methods is difficult and inefficient mainly due to loss of DNA during filtration and precipitation. With advances in molecular pathology, DNA extraction from micro-dissected cells has become essential in handling clinical samples. Genomic DNA extraction using small numbers of cells can be very important to successfully PCR amplify DNA from small biopsy specimens. We compared our experimental genomic DNA extraction method (A) with two other commercially available methods: using spin columns (B), and conventional resins (C), and determined the efficacy of DNA extraction from small numbers of cells smeared on a glass slide. Approximately 50, 100, 200, 500 and 1000 cells were isolated from fine needle aspiration biopsy (FNAB) slides aspirated from histologically proven papillary thyroid carcinoma masses. DNA was extracted using the three techniques. After measuring DNA quantity, PCR amplification was performed to detect the ${\beta}$-globin and $BRAF^{V600E}$ gene mutations. DNA extracted by method (A) showed better yield than the other methods in all cell groups. With our method, a suitable amount of genomic DNA to produce amplification was extracted from as few as 50 cells, while more than 100 to 200 cells were required when methods (B) or (C) were applied. Our genomic DNA extraction method provides high quality and improved yields for molecular analysis. It will be especially useful for paucicellular clinical samples which molecular pathologists often confront when handling fine needle aspiration cytology, exfoliative cytology and small biopsy specimens.

Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.

The Photovoltaic Effect of Iodine-Doped Metal Free Phthalocyanine/ZnO System (Ⅰ) (요오드가 도핑된 무금속 프탈로시아닌/산화아연계의 광기전력 효과(Ⅰ))

  • Heur, Soun-Ok;Kim, Young-Soon;Park, Yoon-Chang
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.3
    • /
    • pp.163-175
    • /
    • 1995
  • Metal free phthalocyanine($H_2Pc$) partially doped with iodine, $H_2Pc(I)x$, has been made to improve photosensitizing efficiency of ZnO/$H_2Pc$. The content of iodine dopant level(x) for $H_2Pc(I)x$ upon $H_2Pc$ polymorphs was characterized as ${\chi}-H_2Pc(I)_{0.92}$ and ${\beta}-H_2Pc(I)_{0.96}$ by elemental analysis. Characterization of iodine-oxidized $H_2Pc$ were investigated by TGA (thermogravimetric analysis), UV-Vis, FT-IR, Raman and ESR (electron spin resonance) spectrum, and the adsorption properties of $H_2Pc(I)x$ on ZnO were characterized by means of Raman and ESR studies. TGA for $H_2Pc(I)x$ showed a complete loss of iodine at approximately 265$^{\circ}C$ and the Raman spectrum of $H_2Pc(I)x$ and ZnO/$H_2Pc(I)x$ at 514.5 nm showed characteristic $I_3^-$ patterns in the frequency region 90∼550 $cm^{-1}$. ZnO/$H_2Pc(I)x$ exhibited a very intense and narrow ESR signal at $g=2.0025{\pm}0.0005$ compared to $H_2Pc$/ZnO. Iodine doped ZnO/$H_2Pc(I)x$ showed a better photosensitivity compared to iodine undoped ZnO/$H_2Pc$. That is, the surface photovoltage of ${\chi}-H_2Pc(I)_{0.92}$/ZnO was approximately 31 times greater than that of ZnO/${\chi}-H_2Pc$ and ZnO/${\beta}-H_2Pc(I)_{0.96}$ was 5 times more efficient than ZnO/${\beta}-H_2Pc$ at 670 nm. And the dependence of photosensitizing effect upon $H_2Pc$ polymorphs was exhibited that the surface photovoltage of ZnO/${\chi}-H_2Pc(I)_{0.92}$ was approximately 5 times greater than ZnO/${\beta}-H_2Pc(I)_{0.96}$ at 670 nm. Therefore Iodine doping of H_2Pc$ resulted in increase in photoconductivity of $H_2Pc$ and photovoltaic effect of ZnO/$H_2Pc$ in the visible region.

  • PDF

Tumor-like Presentation of Tubercular Brain Abscess: Case Report

  • Karki, Dan B.;Gurung, Ghanashyam;Sharma, Mohan R.;Shrestha, Ram K.;Sayami, Gita;Sedain, Gopal;Shrestha, Amina;Ghimire, Ram K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.231-236
    • /
    • 2015
  • A 17-year-old girl presented with complaints of headache and decreasing vision of one month's duration, without any history of fever, weight loss, or any evidence of an immuno-compromised state. Her neurological examination was normal, except for papilledema. Laboratory investigations were within normal limits, except for a slightly increased Erythrocyte Sedimentation Rate (ESR). Non-contrast computerized tomography of her head revealed complex mass in left frontal lobe with a concentric, slightly hyperdense, thickened wall, and moderate perilesional edema with mass effect. Differential diagnoses considered in this case were pilocytic astrocytoma, metastasis and abscess. Magnetic resonance imaging (MRI) obtained in 3.0 Tesla (3.0T) scanner revealed a lobulated outline cystic mass in the left frontal lobe with two concentric layers of T2 hypointense wall, with T2 hyperintensity between the concentric ring. Moderate perilesional edema and mass effect were seen. Post gadolinium study showed a markedly enhancing irregular wall with some enhancing nodular solid component. No restricted diffusion was seen in this mass in diffusion weighted imaging (DWI). Magnetic resonance spectroscopy (MRS) showed increased lactate and lipid peaks in the central part of this mass, although some areas at the wall and perilesional T2 hyperintensity showed an increased choline peak without significant decrease in N-acetylaspartate (NAA) level. Arterial spin labelling (ASL) and dynamic susceptibility contrast (DSC) enhanced perfusion study showed decrease in relative cerebral blood volume at this region. These features in MRI were suggestive of brain abscess. The patient underwent craniotomy with excision of a grayish nodular lesion. Abundant acid fast bacilli (AFB) in acid fast staining, and epithelioid cell granulomas, caseation necrosis and Langhans giant cells in histopathology, were conclusive of tubercular abscess. Tubercular brain abscess is a rare manifestation that simulates malignancy and cause diagnostic dilemma. MRI along with MRS and magnetic resonance perfusion studies, are powerful tools to differentiate lesions in such equivocal cases.

Standards for Applying Reasonable Receive Bandwidth to Suppress Metal Artifacts in MRI (MRI 검사 시 금속 인공물 억제를 위한 합리적인 수신대역폭 적용 기준)

  • Se-Jong Yoo;Min-Cheol Jeon;Nam-Yong An;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1115-1122
    • /
    • 2023
  • This study aimed to present reasonable reception bandwidth application standards for the purpose of suppressing metal objects during MRI examinations. For this purpose, T2 contrast images were acquired using high-speed spin echo technology on a phantom made of screws for spinal surgery, and metal objects were detected. In addition, images were obtained by increasing the reception bandwidth from 100 Hz/PX to 800 Hz/PX by 100 Hz/PX. The metal artifacts were determined as the sum of the areas of the signal attenuation area and the signal accumulation area. In addition, Pearson correlation analysis was performed to analyze the pattern of metal artifacts according to imaging variables. As a result, the signal accumulation area did not change significantly as the reception bandwidth increased (p>0.05), but the signal loss area and the area of metal artifacts decreased as the reception bandwidth increased (p<0.05). Interestingly, the area of metal objects decreased to a maximum in the section where the reception bandwidth was increased from 100 Hz/PX to 200 Hz/PX, consistent with the section where the echo spacing was reduced to a maximum due to the increase in reception bandwidth. In addition, the correlation analysis results also showed that the eco spacing was more related to the signal attenuation area and the area of metal objects than to the reception bandwidth. Therefore, if the reception bandwidth is increased for the purpose of reducing metal objects, it is reasonable to set it based on a value that minimizes the echo spacing in consideration of image quality factors.

Some Factors Affecting Bone Mineral Status of Postmenopausal Women (폐경 후 여성의 골격상태에 영향을 미치는 요인분석)

  • 오세인;이행신;이미숙;김초일;권인순;박상철
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.1
    • /
    • pp.121-129
    • /
    • 2002
  • Osteoporosis, the typical metabolic bone disease of the elderly, is characterized by a reduction in bone mineral density (BMD) and increased fracture risk. Genetic and environmental factors are known to play a key role in bone metabolism, and diet is also considered to be one of the important factors. The purpose of the present study was to investigate the relationship among the factors affecting BMD, including stature, body weight, age, time period since onset of menopause, and biochemical markers of bone turnover in postmenopausal women. Seventy-eight postmenopausal women who visited health promotion center for health examinations volunteered to participate in this study and they were divided into two groups according to the time period since onset of menopause : women with a time period since onset of menopause of less than 5 years (Group 1) and women with a time period since onset of menopause of 5 years or more (Group 2). The demographic characteristics and dietary intake were surveyed using a questionnaire. BMDs of the lumbar spine and femoral neck of subjects were measured by dual energy X-ray absorptiometry. Serum levels of 25-hydroxy-vitamin D and parathyroid hormone (PTH), known to be indicators of bone related hormone status, were anlyzed. Serum samples were measured for calcium, phosphorus, alkaline phosphatase, and osteocalcin as bone formation indicators, and urine was analysed for deoxypyridinoline, creatinine, calcium, and sodium as bone resorption indicators. The results are as follow : The mean BMDs of the lumbar spin and femoral neck were $1.02 \pm 0.02 g/cm^2 and 0.81 \pm 0.02 g/cm^2 respectively, and the BMD level of Group 2 was significantly lower than tat of Group 1 (p<0.01, p<0.05, respectively). The mean daily intake of energy was 1838 $\pm$ 55 kcal. When nutrient intake was compared with the recommended dietary allowances (RDA) of the subjects, only calcium, vitamin A and riboflavin intake showed means lower than the RDA. The nutrient intake did not show any significant differences between Group 1 and 2 Serum and urine levels of biochemical markers of bone turnover did not show any significant differences between Group 1 and 2, and all were within the normal range. However, the PTH and deoxypyridinoline levels showed a tendency to be higher, and the osteocalcin level to be lower in Group 2 than in Group 1. Although age and years after menopause (YAM) showed negative correlations with lumbar spine bone mineral density (LBMD) (r= -0.38, p<0.001, and r= -0.26, p< 0.05, respectively), no correlation was found with femoral neck bone mineral density (NBMD). While height, body weight and body mass index (BMI) showed a positive correlation with LBMD (r= 0.32, p<0.001, r= 0.38, p<0.001, r= 0.22, p= 0.05, respectively), only body weight and BMI showed a positive correlation with NBMD (r= 0.30, p<0.01, and r= 0.27, p<0.05, respectivley). There was no significant corealtion between BMDs and the nutrient intake of subjects, except in the case of carbohydrates (r= 0.22, p<0.05). Also, serum and urine levels of bone turnover markers showed no significant correlation with nutrient intake. On the other hand, serum osteocalcin had a positive correlation with vitamin C intake (r= 0.22, p= 0.05), and urine deoxypyridinolin showed a negative correlation with niacin intake (r= -0.22, p= 0.05). Urinary na was negatively correlated with protein intake(r= -0.23, p= 0.05). The results suggested that it is difficult to prevent the decrease in bone mass among postmenopausal women eating the usual Korean diet. However, the BMDs of the lumbar spine and femoral neck were positively related to body weight ad BMI in postmenopausal women. Therefore, this study confirmed that one of the most effective ways to minimize bone loss in postmenopausal women would be to maintain an adequate body weight with balanced nutrient intake and activity in the pre-and postmenopausal periods.

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF

Significance of brain magnetic resonance imaging(MRI) in the assessment of occupational manganese exposure (직업적 망간 폭로에 있어서 뇌자기공명영상의 의의)

  • 정해관
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.14-30
    • /
    • 1998
  • Manganese is an essential element in the body. It is mainly deposited in the liver and to a lesser degree in the basal ganglia of the brain and eliminated through the bile duct. Rapid turnover of managanese in the body makes it difficult to evaluate the manganese exposure in workers, esecially in those with irregular or intermittent exposure, like welders. Therefore, conventional biomarkers, including blood and urine manganese can provide only a limited information about the long-tern or cumulative exposure to manganese. Introduction of magnetic resonance imaging (MRI) made a progress in the assessment of manganese exposure in the medical conditions related to manganese accumulation, e. g. hepatic failure and long-term total parenteral nutrition. Manganese shortens spin-lattice(T1) relaxation time on MRI due to its paramagnetic property, resulting in high signal intensity (HSI) on T1-weighted image(T1W1) of MRI. Manganese deposition in the brain, therefore, can be visualizedas an HSI in the globus pallidus, the substantia nigra, the putamen and the pituitary. clinical and epidemiologic studies regarding the MRI findings in the cases of occupational and non-occupational manganese exposure were reviewed. relationships between HSI on T1W1 of MRI and age, gender, occupational manganese exposure, and neurological dysfunction were analysed. Relationships betwen biological exposure indices and HSI on MRE werealso reviewed. Literatures were reviewed to establish the relationships between HSI, Manganese deposition in the brain, pathologic findings, and neurological dysfunction. HSI on T1W1 of MRI reflects regional manganese deposition in the brain. This relationship enables an estimation of regional manganese deposition in the brain by analysing MR signal intensity. Manganese deposition in the brain can induce a neuronal loss in the basal ganglia but functional abnormality is supposed to be related to the cumulative exposure of manganese in the brain, use of brain MRI for the assessment of exposure in a group of workers seems to be hardly rationalized, while ti can be a useful adjunct for the evaluation of manganese exposure int he cases with suspected manganese-related health problems.

  • PDF