• Title/Summary/Keyword: Spherical radius

Search Result 145, Processing Time 0.017 seconds

Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery (정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인)

  • Kang, Young-Nam;Lee, Dong-Jun;Kwon, Soo-Il;Kwon, Yang
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 1996
  • It is important that the precise decision of the region and the accurate delivery of radiation dose required for treatment in the stereotactic radiosurgery. In this research, radiosurgery was carried with Leksell streotactic frame(LSF) which is especially developed water phantom to verify in experiment. Leksell Gamma Knife and LSF are used in radiosurgery is the spherical water phantom has the thickness of 2 mm, the radius of 160mm. The film for target localization and ionchamber for dose delivery was used in measurement instruments We compare the coordinate of target which is initialized by biplannar film with simple X-ray to the coordinate of film measured directly. The calculated dose by computer simulation and the measured dose by ionization chamber are compared. In this research, the target localization has the range ${\pm}$0.3mm for the acceptable error range and the absolute dose is :${\pm}$0.3mm for the acceptable error range. This research shows that the values measured by using the especially manufactured phantom are included the acceptable error range. Thus, this water phantom will be used continuously in the periodic quality assurance of Gamma Knife Unit and Leksell Stereotactic Frame.

  • PDF

Relationship of Refractive and Anatomical Changes on Eyes after Alcohol Ingestion (알코올 섭취에 의한 눈의 굴절변화와 해부학적 변화와의 관계)

  • Kim, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.

Chain Length Effect on the Configurational Properties of an n-Alkane Chain in Solution

  • Jeon, Seung-Ho;Ree, Tai-Kyue;Oh, In-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.5
    • /
    • pp.367-371
    • /
    • 1986
  • Dynamic and equilibrium properties of n-alkane chains immersed in solvent molecules have been investigated by a molecular dynamics method. The n-alkane chain is assumed to be a chain of elements (CH$_2$) interconnected by bonds having a fixed bond length and bond angle, but each bond of the chain is allowed to execute hindered internal rotation. We studied the effect of the number of the chain elements (N$_c$ = 10, 15 and 20) on the equilibrium properties of the system, e.g., the pair correlation functions between a chain element and solvent molecules, g$_{cs}$(r), and between the chain elements, g$_{cc}$(r), and the configurational properties such as the mean-square end-to-end distance < R$^2$ >, the mean-square radius of gyration < S$^2$ >, and the eigenvalues of the moment-of-inertia tensor < S$_i^2$ > / < S$^2$ > (i = 1, 2 and 3). We also studied the dynamic properties of the system, e.g., the autocorrelation function C(A;t) where A = R$^2$(t), = S$^2$(t), or = ${\vec{V}}(t)({\vec{V}}$ = velocity of the center of mass), and the diffusion coefficient D. The g$_{cs}$(r)'s are almost equal irrespective of the change of Nc while g$_{cc}$(r) becomes larger as N$_c$ increases; The MD computed configurational properties < R$^2$2 > and < S$^2$ > were found to be a little different from the values calculated from the statistical equations of < R$^2$ > and < S$^2$ >, it may be due to the fact that our model for the MD simulations includes a long-range volume effect. From the < S$_i^2$ > / < S$^2$ >, it is found that the chain molecule has a nearly spherical shape irrespective of the variation of N$_c$. For the dynamic properties we found that the C(R$^2$;t) and C(S$^2$;t) of lower N$_c$ decay faster than those of higher N$_c$, while the C($\vec V$;t) of the center of mass in the chain is weakly dependent on the N$_c$. The center of mass diffusion coefficient D$_c$ decreases as N$_c$ increases while the end point diffusion coefficient D$_e$ is nearly equal irrespective of the change of N$_c$.

Surface-error Measurement for a Convex Aspheric Mirror Using a Double-stitching Method (이중 정합법을 이용한 볼록비구면 반사경의 형상 오차 측정)

  • Kim, Goeun;Lee, Yun-Woo;Yang, Ho-Soon
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.314-322
    • /
    • 2021
  • A reflecting telescope consists of a concave primary mirror and a convex secondary mirror. The primary mirror is easy to measure, because it converges the beam from an interferometer, while the secondary mirror diverges the beam and so is not easy to measure, even though it is smaller than the primary mirror. In addition, the Korsch-type telescope uses the central area of the secondary mirror, so that the entire area of the secondary mirror needs to be measured, which the classical Hindle test cannot do. In this paper, we propose a double-stitching method that combines two separate area measurements: the annular area, measured using the Hindle stitching method, and the central area, measured using a spherical wave from the interferometer. We test the surface error of a convex asphere that is 202 mm in diameter, with 499 mm for its radius of curvature and -4.613 for its conic constant. The surface error is calculated to be 19.5±1.3 nm rms, which is only 0.7 nm rms different from the commercial stitching interferometer, ASI. Also, the two results show a similar 45° astigmatism aberration. Therefore, our proposed method is found to be valuable for testing the whole area of a convex asphere.

Influence of electrode geometry on electrical resistivity survey: Numerical study (전극의 기하학적 형상이 전기비저항 탐사에 미치는 영향: 수치 해석 연구)

  • Tae-Young Kim;Seung-Hun Lee;Hee-Hwan Ryu;Song-Hun Chong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.101-120
    • /
    • 2023
  • Electrical resistivity survey have been widely conducted at diverse scales, from a few centimeters for laboratory tests to kilometers for field tests. It measures electrical resistance through relationship of electric potential difference and current between two electrodes penetrated on the surface of medium, and eventually quantifies electrical resistivity known as inherent properties of the medium. In field or full-scale test, it assumes the electrodes as equivalent half-sphere electrodes that have a same surface area with different electrodes for ease of calculation because the contact area between electrode and medium is small and sufficient distance between two electrodes. However, small-scale laboratory test is significantly affected by the electrode geometries (penetrated depth, height, radius of electrode and distance between electrodes), which change the equipotential surface and electric current flow. Indeed, the electrode geometries may eventually cause a difference of electrical resistivity value. This study reviews the theoretical electrical resistance derived with various electrode geometries (half-sphere, cylinder, cylindrical with half-spherical tip, cylindrical with conical tip) and verifies the developed numerical module by comparing results with the theoretical electrical resistance. The distributions of electrical resistance around electrodes and among electrodes are analyzed. In addition, it is discussed how the electrical characteristic of cylindrical electrode with conical tip widely used in field test has effect on the electric current flow.