• Title/Summary/Keyword: Speed Regulation

Search Result 392, Processing Time 0.029 seconds

Study on Constant Speed Drive Method of SRM (SRM의 정속도 운전방식에 관한 연구)

  • Jung, Tae-Uk;Oh, Seok-Gyu;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.30-32
    • /
    • 1995
  • The SRM has high efficiency, a wide speed range, high speed capability and DC-series Motor characteristics. So the SRM has been studied as adjustable speed machine. The speed of SRM can be adjusted to switching angle and exciting voltage. This paper suggests an constant speed drive method of SRM. In this method, the speed is controlled by voltage regulation using PI control and the torque is controlled by advance angle in accordance with, load torque variation.

  • PDF

Design of Speed Controller for Stall Blade Wind Turbine Complying with the Speed Limit During Speed Overshoot (속도 오버슈트 발생 시 제한 속도를 초과하지 않는 실속형 블레이드 풍력터빈의 속도제어기 설계)

  • Kim, Ye-Chan;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.438-445
    • /
    • 2022
  • Blade efficiency decreases when the rotor speed is kept constant even though the wind speed is higher than the rated value. Therefore, a speed controller is used to regulate the rotor speed in the high-wind-speed region. In stall-blade wind turbine, the role of the speed controller is important because precise aerodynamic regulation is unavailable. In this study, an effective parameter design method of a PI speed controller is proposed to limit the speed overshoot of a type 4 wind turbine with stall blades even though wind gust occurs. The proposed method considers the efficiency characteristics of the stall blade and the mechanical inertia of the wind turbine rotor. It determines the bandwidth of the speed controller to comply with the speed limit during generator speed overshoot for the worst case of wind gust. The proposed method is verified through intensive simulations with a MATLAB/SIMULINK model and experimental results obtained using a 3 kW MG set of wind turbine simulator.

Stand-Alone Pico-Hydro Generation System using a High-Efficiency IPM Synchronous Generator

  • Kurihara, Kazumi;Kubota, Tomotsugu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.121-125
    • /
    • 2014
  • This paper presents a successful stand-alone pico-hydro generation system using a high-efficiency interior permanent-magnet (IPM) synchronous generator. A 1-kW 4-pole V-type IPM generator with low voltage regulation is used for laboratory test in stand-alone hydro energy conversion system. It has been found from experimental results that the constant output voltage is supplied stably by the proposed system under wide speed range.

Induction Motor Direct Torque Control with Fuzzy Logic Method

  • Chikhi, Abdessalem;Chikhi, Khaled
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.234-239
    • /
    • 2009
  • In this article we present the simulation results of induction motor speed regulation by direct torque control with a classic PI regulator. The MATLAB Simulink programming environment is used as a simulation tool. The results obtained, using a fuzzy logic, shows the importance of this method in the improvement of the performance of such regulation.

Control of Rotational Angular Speed using Magneto-rheological Fluid (자기유변유체를 이용한 회전 각속력 제어)

  • 신성철;정재성;김정훈;이종원
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.67-72
    • /
    • 1999
  • A magneto-rheological(MR) fluid based rotary loading and braking device is developed. The loading and braking forces of the device are accurately adjustable by controlling the yield stress of MR fluid, so that the vibration control, the precision position control and the speed control of rotating machines equipped with the device can be achieved. As an engineering application, constant rotational speed regulation is conducted using the device manufactured in laboratory, introducing PI control action not only with varying torque due to gravitation, with initial angular speed, but also with constant external torque made by hand. To do this, first, mathematical model was obtained via experiments. And then, simulation was carried out, based on the experimentally identified model. Its result was confirmed through experiment. It is identified by simulation and experimental results that PI action leads to satisfactory control performance in both cases that varying torque due to gravitation, with initial angular speed, and constant external torque are applied.

  • PDF

Fatigue Life Evaluation of Motor Block Bracket Units for KTX-Sancheon Trains (KTX-산천 열차용 모터 감속기 고정대의 피로 수명 평가)

  • Lee, Chan-Woo;Lee, Dong-Hyong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.626-631
    • /
    • 2012
  • In this study, fatigue life of the motor block bracket units for KTX-Sancheon trains was assessed. Design evaluation for railway structures was performed based on the UIC 566 regulation, and test and evaluation of fatigue life in welded parts was performed in accordance with standard ERRI B 12/RP17 and ERRI B 12/RP60. The actual vehicle dynamic stress testing was executed in KTX-Sancheon service line with the service operating speed. The dynamic stress was measured with commercial data acquisition system (MGC plus). The cumulative damage was evaluated by applying standard BS 7608 - Class F and cycle counting was used rain-flow counting method. As a result, the motor block bracket units for KTX-Sancheon trains was designed to fit the regulation and the safety of fatigue life for 30 years, assuming that KTX-Sancheon trains travels 600,000km annually, were confirmed under current operating conditions.

Static VAR Compensator-Based Voltage Regulation for Variable-Speed Prime Mover Coupled Single- Phase Self-Excited Induction Generator

  • Ahmed, Tarek;Noro, Osamu;Sato, Shinji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.185-196
    • /
    • 2003
  • In this paper, the single-phase static VAR compensator (SVC) is applied to regulate and stabilize the generated terminal voltage of the single-phase self-excited induction generator (single-phase SEIG) driven by a variable-speed prime mover (VSPM) under the conditions of the independent inductive load variations and the prime mover speed changes The conventional fixed gain PI controller-based feedback control scheme is employed to adjust the equivalent capacitance of the single-phase SVC composed of the fixed excitation capacitor FC in parallel with the thyristor switched capacitor TSC and the thyristor controlled reactor TCR The feedback closed-loop terminal voltage responses in the single-phase SEIG coupled by a VSPM with different inductive passive load disturbances using the single-phase SVC with the PI controller are considered and discussed herem. A VSPM coupled the single-phase SEIG prototype setup is established. Its experimental results are illustrated as compared with its simulation ones and give good agreements with the digital simulation results for the single-phase SEIG driven by a VSPM, which is based on the SVC voltage regulation feedback control scheme.

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

A Study Fast Response Control of Induction Motor by Vector Control Algorithm (벡터제어 알고리즘에 의한 유도전동기의 속응제어에 관한 연구)

  • Hwang, Lak-Hoon;Jang, Jin-Hyog;Shin, Yang-Ho;Lee, Chun-Sang;Cho, Mun-Teak
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1172-1175
    • /
    • 2001
  • Recently, vector control without a speed sensor for an inverter induction motor system has been developed. In this paper describes the vector control system estimates rotor speed based on FMRAS(Flux Model Reference Adaptive System). Because of improving the initial condition and drift problem by pure integrator is eliminated, we can be expected to rapid responsibility of the speed estimation. The stability of speed estimator is proved on the basis of hyperstability theory. Proposed control system used TMS320C31 DSP for high speed processing. The effectiveness of the proposed system is verified by simulation and experimental results. This result shows that the highly characteristic speed estimation and robust character of load regulation.

  • PDF

A SPEED CONTROLLER FOR VEHICLES USING FUZZY CONTROL ALGORITHM WITH SELF0LEARNING (자기 학습 능력을 가진 퍼지 제어기를 이용한 차량의 속력 제어기 개발)

  • 정승현;김상우
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.880-883
    • /
    • 1996
  • This paper suggests a speed control algorithm for the ICC(Intelligent Cruise Controller) system. The speed controller is designed using the fuzzy controller which shows the good performance in nonlinear system having the complex mathematical model. The fuzzy controller was equipped with the capability of a self-learning in real time in order to maintain the good performance of the speed controller in a time-varying environment the self-learning properties and the performance of the fuzzy controller are showed via computer simulation. The suggested fuzzy controller will be applied to the PRV-III which is our test vehicle.

  • PDF