• Title/Summary/Keyword: Spectrum analyzing

Search Result 312, Processing Time 0.029 seconds

A Study on the Frequency Analyzing of Leak Evaluation m Valve for Power Plant Using AE (AE법에 의한 발전용 밸브누설평가를 위한 주파수분석 연구)

  • LEE SANG-GUK
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.360-364
    • /
    • 2004
  • The objective of this study is to estimate the feasibility of acoustic emission method Jar the internal leak from the valves in nuclear power plants. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. From the comparison of background noise data with the experimental results as to relation between leak flow and acoustic signal, the minimum leak flow rates that am be detected by acoustic signal was suggested. When the background noise level are higher than the acoustic signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum.

  • PDF

Noise-source Analysis of Tactical Vehicle Using Partial Coherence Function (부분기여도함수를 이용한 전술차량 소음원 분석)

  • Park, Sungho;Lee, Kyunghyun;Han, HyungSuk;Jeon, Soohong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.774-780
    • /
    • 2016
  • In this paper noise source and transfer path of tactical vehicle are analyzed with partial coherence function and spectrum analysis. Engine, transmission, structure panel and aerodynamic are main source of cabin noise. To reduce cabin noise, identifying transfer path of sources and analyzing their contribution is important. With modeling of transfer path and partial coherence function, transfer path and principal noise source can be identified. Engine/transmission and structural resonance are principal source of low frequency noise and by adding stiffener and sound absorbing material, resonance of vibration and inflow air problem can be solved.

축방향 하중을 받는 앵귤러 콘택트 볼베오링의 수명특성에 관한 실험적 연구

  • Hwang, Pyung;Kwon, Sung-In
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.53-59
    • /
    • 1996
  • The new trends in main spindle design of Machining Center are focused on high-speed, high-precision and high-stiffness. As a main spindle bearing, the angular-contact ball bearing is well used. A rolling bearing is usually only a small part of a larger mechanical system, but its performance can have a great influence on the functioning of the whole machine. This work is about fatigue life tester design and monitoring of defected rolling-element bearings. The major work is done via experiments and the vibration signal is analysised by means of frequency spectrum technique. By analyzing the frequency spectrum, it is possible to view the condition of the bearings.

  • PDF

Electron Beam Welding Diagnosis Using Wavelet Transform (웨이브렛 변환을 이용한 전자빔 용접 진단)

  • 윤충섭
    • Journal of Welding and Joining
    • /
    • v.21 no.6
    • /
    • pp.33-39
    • /
    • 2003
  • Wavelet transform analysis results show a spectrum energy distribution of CWT along scale factors distinguish the partial, full and over penetration in a electron beam welding by analyzing the curve of spectrum energy at small scale, middle and large scale range, respectively. Two types of signals collected by Ion collector and x-ray sensors and analyzed. The acquired signals from sensors are very complicated since these signals are very closely related the dynamics of keyhole which interact the very high density energy with materials during welding. The results show the wavelet transform is more effective to diagnosis than Fourier Transform, further for the general welding defects which are not a periodic based, but a transient, non-stationary and time-varying phenomena.

The Identification of Vibration Sources in Optical Disk Drive Using PCF Method (PCF 기법을 이용한 광디스크 드라이브의 진동원 규명)

  • 함경훈;장영배;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.127-133
    • /
    • 2002
  • After the vibration source is searched in optical disk drive as an information storage device broadly used the influence of it against FES(Focusing Error Signal) which is a kind of positioning error of pick up from the circuit is carefully examined. For that Purpose, partial coherence function method is applied on a simple multi-degree of freedom model made for the theoretical verification and it is practically introduced in optical disk drive for analyzing the effect of vibration source. Finally, partial coherence output spectrum is attentively observed in order to know which vibration source is a great influence on FES.

  • PDF

Energy Efficiency Modelling and Analyzing Based on Multi-cell and Multi-antenna Cellular Networks

  • Ge, Xiaohu;Cao, Chengqian;Jo, Min-Ho;Chen, Min;Hu, Jinzhong;Humar, Iztok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.4
    • /
    • pp.560-574
    • /
    • 2010
  • In this paper, the relationship between the energy efficiency and spectrum efficiency in a two-cell cellular network is obtained, and the impact of multi-antenna on the energy efficiency of cellular network is analyzed and modeled based on two-state Markovian wireless channels. Then, the energy efficiency of multi-cell cellular networks with co-channel interference is investigated. Simulation results verify the proposed model and the energy-spectrum efficiency tradeoffs in cellular networks with multi-antenna and co-channel interference.

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

A study on the implementation of optical absorption spectrum analyzer for detecting gases in OF power cable (OF 케이블 Gas 검출을 위한 광흡수 스펙트럼 분석장치 구현에 관한 연구)

  • Oh, S.K.;Kang, D.S.;Kim, Y.H.;Kang, U.;Ryoo, H.S.;Park, H.S.;Roh, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2450-2452
    • /
    • 1999
  • Presently, it is now developing the optical remote gas sensor system which can measure combustible gases such as $CH_4$ and $C_2H_2$ generating by partial discharges inside the cable and connection parts to detect thermal deterioration of Oil-Filled (OF) power cable at the appropriate time. It is the most important parameter to select central wavelength of laser diode (LD) by analyzing the absorption bend of measuring gases in the infrared region. In this research, we proposed the optical spectrum analyzer to absorption band of $CH_4$ and $C_2H_2$ for the preliminary research of optical fiber gas detecting system.

  • PDF

A Study on the Optical Image Deblurring by Spectrum Analysis (스펙트럼 분석에 의한 광영상 복원에 관한 연구)

  • Lee, Seung Hyun;Kim, Eun Soo;Young, In Eung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.4
    • /
    • pp.529-534
    • /
    • 1986
  • A holographic iverse filter has been used for optical image deblurring by modeling the PSF(point spread function)of blurred system. This paper presents the optical image restoration of an accidentally blurred photograph by using a simgle inverse filter which is obtained from a blurrec PSF by analyzing the Fourier spectrum of the supposely defocused photograph itself. The filter, a positive transparency having gamma of 2, has amplitude and phase informations simulatneously.

  • PDF