• Title/Summary/Keyword: Spectrum Quantification

Search Result 59, Processing Time 0.027 seconds

Quantitative Analysis of Amylose and Protein Content of Rice Germplasm in RDA-Genebank by Near Infrared Reflectance Spectroscopy (근적외선 분광분석법을 이용한 벼 유전자원의 아밀로스 함량과 단백질 함량 정량분석)

  • Kim, Jeong-Soon;Cho, Yang-Hee;Gwag, Jae-Gyun;Ma, Kyung-Ho;Choi, Yu-Mi;Kim, Jung-Bong;Lee, Jeong-Heui;Kim, Tae-San;Cho, Jong-Ku;Lee, Sok-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.217-223
    • /
    • 2008
  • Amylose and protein contents are important traits determining the edible quality of rice, especially in East Asian countries. Near-Infrared Reflectance Spectroscopy (NIRS) has become a powerful tool for rapid and nondestructive quantification of natural compounds in agricultural products. To test the practically of using NIRS for estimation of brown rice amylose and protein contents, the spectral reflectances ($400{\sim}2500\;nm$) of total 9,483 accessions of rice germplasm in Rural development Administration (RDA) Genebank ere obtained and compared to chemically determined amylose and protein content. The protein content of tested 119 accessions ranged from 6.5 to 8.0% and 25 accessions exhibited protein contents between 8.5 to 9.5%. In case of amylose content, all tested accessions ranged from 18.1 to 21.7% and the grade from 18.1 to 19.9% includes most number of accessions as 152 and 4 accessions exhibited amylose content between 20.5 to 21.7%. The optimal performance calibration model could be obtained from original spectra of brown rice using MPLS (Modified Partial Least Squares) with the correlation coefficients ($r_2$) for amylose and protein content were 0.865 and 0.786, respectively. The standard errors of calibration (SEC) exhibited good statistic values: 2.078 and 0.442 for amylose and protein contents, respectively. All these results suggest that NIR spectroscopy may serve as reputable and rapid method for quantification of brown rice protein and amylose contents in large numbers of rice germplasm.

Simultaneous Determination of Hesperidin and Glycyrrhizin in Pyungwi-san by HPLC/DAD (HPLC-DAD를 이용한 평위산 중의 Hesperidin 및 Glycyrrhizin의 동시분석법 확립)

  • Lee, Mi-Kyeong;Choe, Ok-Gyeong;Park, Jin-Ho;Cho, Jung-Hee;Kim, Do-Hoon;Baek, Ju-Hyun;Kim, Hyo-Jin;Lee, Ki-Yong;Kim, Sang-Du;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.39 no.3
    • /
    • pp.199-202
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of hesperidin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Pyungwi-san (PWS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 ml/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of hesperidin and glycyrrhizin in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All four compounds showed good linearity $(r^2>0.995)$ in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.0% and the limits of detection (LOD) were less than 60 ng. The mean recovery of each compound was 99.0-105.6% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of hesperidin and glycyrrhizin in three commercial products of PWS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial PWS products.

Accelerated Life Evaluation of Propeller Shaft for Forklift Truck (지게차용 추진축의 가속 수명 평가)

  • Kim, Do-Sik;Sung, Baek-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1221-1229
    • /
    • 2014
  • This paper proposes an approach for predicting the fatigue life of a propeller shaft of a forklift truck by an accelerated life test method. The accelerated life test method adopted in this study is the calibrated accelerated life test, which is highly effective in the prediction of the lifetime and enables significant reduction of the test time as well as a quantification of reliability in the case of small sample sizes. First, the fatigue test was performed under two high stress levels, and then, it was performed by setting low stress levels in consideration of the available test time and extrapolation. Major reliability parameters such as the lifetime, accelerated power index, and shape parameter were obtained experimentally, and the experimentally predicted lifetime of the propeller shaft was verified through comparison with results of an analysis of load spectrum data under actual operating conditions.

Quantitative Analysis and Qualification of Acrylamide Using LC/ESI-MS (LC/ESI-MS를 이용한 Acrylamide의 정성확인 및 정량분석)

  • Park Chan-Koo;Jo Sung-Ja;Chough Nam-Joon;Kim Min-Young;Sohn Jong-Ryeul;Moon Kyong-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.4 s.54
    • /
    • pp.25-33
    • /
    • 2004
  • Acrylamide, difficult to analyze by GC and GC/MS due to the polarity and low volatility, was analyzed by LC/ESI/MS in the study. Acrylamide its(molecular weight 71amu) showed m/z=72 $(M+H)^+$ and high peak intensity at 22V in SIR mode. The mass spectrum ratios of acrylamide for qualitative identification had m/z=72 in precursor ion and m/z=55 in products ion, respectively. Those ratios at 30V in SIR mode ranged from 1: 1.4 to 1:1.17 despite various acrylamide concentrations. The ion intensity ratios of acrylamide $(m/z=72,\; [M+H]^+)$ to acrylamide isotopes $(m/z=73,\;[M+H]^+)$ ranged from 100 : 3.57 to 100 : 3.92. The results verified theoretical mass spectrum ratio that was 100:3.82. The linearity of standard calibration curve was y : 520.584x + 1815.26 with $r^2=0.99.$ In quality assurance and quality control, the recovery rate ranged from 81.64 percent to 90.97 percent and relative standard deviation was less than $10\%$ with 5 repeated injections at individual standard calibration solutions. The method was applied to analyze acrylamide in food at grocery stores. Snacks made of potatoes showed the highest acrylamide concentration followed by products made of French fries, wheat, and corn.

Isolation and Quantitative Analysis of Tricin from Ears of Phragmites communis (갈대이삭으로부터 Tricin의 분리 및 함량 분석)

  • Woo, Hyun Sim;Lee, Seung-Young;Hwang, Buyng Su;Jeong, Sang-Chul;Kim, Dae Wook
    • Korean Journal of Pharmacognosy
    • /
    • v.48 no.1
    • /
    • pp.77-81
    • /
    • 2017
  • The aim of this study was to investigate a validation method for determination of tricin in Phragmites communis ears. Tricin was isolated with chromatographic methods and used as the standard substances for quantitative analysis. The structural determination was characterized by comparing their NMR spectral data with values reported in the literature. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of tricin was measured by HPLC. The results show that the specificity was satisfied with retention time and diode array detector (DAD) spectrum by analysis of tricin using HPLC. The limits of detection (LOD) for tricin was 0.84 mg/ml. Recovery of tricin was 98.80~108.22% with R.S.D values less than 2%. Intra-day and inter-day precisions of tricin in P. communis ears were 99.96~100.96% and 99.01~100.40%, respectively. Therefore, application of tricin was validated by an analytical method as major compound in P. communis ears.

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin;Lim, Cheol-Soo;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2017
  • Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

Identification of C3G(cyanidin-3-glucoside) from Mulberry Fruits and Quantification with Different Varieties (오디에서 C3G(cyanidin-3-glucoside)의 분리, 동정 및 계통별 함량분석)

  • 김현복;김선림
    • Journal of Sericultural and Entomological Science
    • /
    • v.45 no.2
    • /
    • pp.90-95
    • /
    • 2003
  • This study was carried out to identify of C3G (cyanidin-3-glucoside) from mulberry fruits and quantify with different varieties. C3G of mulberry fruits was extracted with 1% HCl-MeOH and purified with open column (5${\times}$90cm) which filled with Amberlite IRC-50 ion exchange resin. The $\lambda$max ranges of the purified C3G on UV/vis spectrum were 516nm and 280nm. Also, molecular weight of C3G from mulberry fruits by LC-Mass was determined as 449. From above results, we concluded that anthocyanin pigment of mulberry fruits was C3G only. The cyanidin-3-glucoside (C3G) was separated and quantified by High Performance Liquid Chromatography (HPLC) system using a Nova-Pack C$\_$18/ column. Mean content of the 35 tested accessions was 0.89%. Also fruity characteristics as well as C3G content to select the desirable mulberry varieties for the production of fruit were researched and analyzed. We selected three suitable varieties such as 'Susungppong', 'Kangsun', and 'Jeolgokchosaeng(Chungpuk)'.

Identification and Quantification of Glucosinolates in Rapeseed (Brassica napus L.) Sprouts Cultivated under Dark and Light Conditions

  • Lee, Min-Ki;Arasu, Mariadhas Valan;Chun, Jin-Hyuk;Seo, Jeong Min;Lee, Ki-Teak;Hong, Soon-Taek;Kim, In Ho;Lee, Yong-Hwa;Jang, Young-Seok;Kim, Sun-Ju
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • BACKGROUND: This study was performed for the identification and quantification of glucosinolate (GSL) contents in seven varieties of rapeseed (Brassica napus L.) sprouts cultivated under dark and light conditions. METHODS AND RESULTS: Crude glucosinolates (GSLs) were desulfated by treating with aryl sulfatase and purified using diethylaminoethyl sepharose (DEAE) anion exchange column. Individual GSLs were quantified using high-performance liquid chromatography (HPLC) with electrospray ionization-tandem mass spectrometry (ESI-MS/MS). Eleven GSLs including six aliphatic (progoitrin, sinigrin, glucoalyssin, gluconapoleiferin, gluconapin, and glucobrassicanapin), four indolyl (4-hydroxyglucobrassicin, glucobrassicin, 4-methoxyglucobrassicin, and neoglucobrassicin) and one aromatic (gluconasturtiin) were identified based on the fragmentation patterns of MS spectrum. Aliphatic GSLs were noted as the predominant group with average 85.2% of the total contents. The most abundant GSLs were progoitrin which was ranged at $8.14-118.68{\mu}mol/g$ dry weight (DW). The highest total GSL amounts were documented in 'Hanra' ($146.02{\mu}mol/g$ DW) under light condition and 'Mokpo No. 68' ($86.67{\mu}mol/g$ DW) in dark condition, whereas the lowest was in 'Tamra' (30.13 and $14.50{\mu}mol/g$ DW) in both conditions. The sum of aliphatic GSLs attributed > 80% in all varieties, except 'Tamra' (67.7% and 64.9% in dark and light conditions, respectively) in the total GSL accumulation. Indolyl GSLs were ranged $2.41-15.73{\mu}mol/g$ DW, accounted 2.78-33.6% of the total GSLs in rapeseed varieties. CONCLUSION(S): These results provide valuable information regarding potential beneficial GSL contents individually. This study attempts to contribute to knowledge of the nutritional properties of the different varieties of rapeseed plants. These results may be useful for the evaluation of dietary information.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.