• Title/Summary/Keyword: Spectroscopic Method

Search Result 527, Processing Time 0.02 seconds

Fabrication of Conducting Polymer Thin Films Using Molecular Layer Deposition

  • Han, Gyu-Seok;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.289-289
    • /
    • 2011
  • The conducting polymer thin films were deposited using the gas phase method which known as molecular layer deposition (MLD). Terephthalaldehyde (TPA) and p-phenylenediamine (PD) were used as monomers to deposit conducting polymer. Self-terminating nature of TPA and PD reaction were demonstrated by growth rate saturation versus precursors dosing time. Infrared spectroscopic and X-ray photoelectron spectroscopy were employed to determine the chemical composition and state of conducting polymer thin films. Layer by layer growth and polymerization of thin films can be showed by shifting of absorption edge using UV-VIS spectroscopy. This conducting polymer fabricated by using MLD method gives the opportunity to develop new hybrid materials by combining inorganic materials in nanoscale.

  • PDF

CALCULATION OF TELLURIC ABSORPTION SPECTRA (지구 대기 흡수선 스펙트럼 계산)

  • Jeong, Gwanghui;Han, Inwoo;Lee, Byeong-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.29 no.3
    • /
    • pp.35-44
    • /
    • 2014
  • In ground-based astronomical spectroscopic observations, there are many telluric absorption lines that are laid on the spectra of celestial objects. To study the physical properties of the celestial objects with these contaminated spectra, the telluric lines should be removed. A conventional method for removing the telluric lines is using the standard stellar spectrum as telluric line. In this paper, we introduce a technique to calculate synthetic telluric spectra and use them to remove telluric lines from a spectrum of a celestial object. We used Line-by-Line Radiative Transfer Model (LBLRTM) for calculating a synthetic spectrum and selected Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) model as atmospheric model. We apply our method to some spectra obtained by Bohyunsan Observatory Echelle Spectrograph (BOES) to show that the telluric lines are well removed from the observed spectra by our model within an accuracy of 2% which is close to the 1-sigma rms of the original spectra.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

A study of Nickel Oxide thin film deposited by DC magnetron and RF sputtering method (DC magnetron 방법과 RF 스퍼터링 방법으로 제작된 Nickel Oxide 박막의 특성 연구)

  • Choi, Kwang-Nam;Park, Jun-Woo;Baek, Seoung-Ho;Lee, Ho-Sun;Kwak, Sung-Kwan;Chung, Kwan-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.441-442
    • /
    • 2007
  • We deposited nickel oxide(NiO) thin films on silicon(Si) substrates at Room temperature and $500^{\circ}C$ using a nickel target by reactive DC and RF sputtering. In addition, we anneal to NiO thin films deposited at room temperature. Using spectroscopic eillipsometry, we obtained optical characteristics of every films. We discussed relations of the optical and structural properties of NiO thin films with the oxygen flow rate, substrate temperature and annealing temperatures. Refraction was decreased and defect was increased when NiO thin films was annealed. We also analyzed the electrical characteristics of NiO films which deposited DC and RF sputtering method.

  • PDF

Determination of Research Octane Number using NIR Spectral Data and Ridge Regression

  • Jeong, Ho Il;Lee, Hye Seon;Jeon, Ji Hyeok
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Ridge regression is compared with multiple linear regression (MLR) for determination of Research Octane Number (RON) when the baseline and signal-to-noise ratio are varied. MLR analysis of near-infrared (NIR) spectroscopic data usually encounters a collinearity problem, which adversely affects long-term prediction performance. The collinearity problem can be eliminated or greatly improved by using ridge regression, which is a biased estimation method. To evaluate the robustness of each calibration, the calibration models developed by both calibration methods were used to predict RONs of gasoline spectra in which the baseline and signal-to-noise ratio were varied. The prediction results of a ridge calibration model showed more stable prediction performance as compared to that of MLR, especially when the spectral baselines were varied. . In conclusion, ridge regression is shown to be a viable method for calibration of RON with the NIR data when only a few wavelengths are available such as hand-carry device using a few diodes.

Enzymatic Hydrolysis of p-Nitrophenyl Phsphoryl Derivatives by Phospholipase D

  • Cha, Joo-Yeun;Lee, Ji-Eun;Koh, Eun-Hie;Choi, Myung-Un
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.1001-1003
    • /
    • 1994
  • A series of phosphodiesters of p-nitrophenyl phosphoryl derivatives were synthesized and used as a model substrate for phospholipase D (PLD). The phosphodiester substrates were synthesized from p-nitrophenyl phosphorodichloridate and corresponding alcohols with different chain lengths and polar groups. To measure the activity of PLD, either spectroscopic method for p-nitrophenol or pH-stat titration method was employed. For each substrate, effects of substrate concentration, pH, and $Ca^{2+}$ ion were examined. The kinetic parameters $V_{max}$ for the different substrates were varied depending on the chain lengths or charge of the alcohols. No calcium effect was observed in the hydrolysis of neutral and negatively charged alcohol derivatives, while positively charged choline derivative showed a strong $Ca^{2+}$ ion dependence.

Direct Time-domain Phase Correction of Dual-comb Interferograms for Comb-resolved Spectroscopy

  • Lee, Joohyung
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.289-297
    • /
    • 2021
  • We describe a comb-mode resolving spectroscopic technique by direct time-domain phase correction of unstable interferograms obtained from loosely locked two femtosecond lasers. A low-cost continuous wave laser and conventional repetition rate stabilization method were exploited for locking carrier and envelope phase of interferograms, respectively. We intentionally set the servo control at low bandwidth, resulting in severe interferograms' fluctuation to demonstrate the capability of the proposed correction method. The envelope phase of each interferogram was estimated by a quadratic fit of carrier peaks to correct timing fluctuation of interferograms in the time domain. After envelope phase correction on individual interferograms, we successfully demonstrated 1 Hz linewidth of RF comb-mode over 200 GHz optical spectral-bandwidth with 10-times signal-to-noise ratio (SNR) enhancement compared to the spectrum without correction. Besides, the group delay difference between two femtosecond pulses is successfully estimated through a linear slope of phase information.

Measurement of Concentration of Highly Concentrated Samples and Reaction Kinetics through Color Analysis (광학적 색상 분석을 이용한 고농도 시료의 농도 및 반응 속도 측정법)

  • Euna Lee;Ji Woong Chang
    • Applied Chemistry for Engineering
    • /
    • v.34 no.2
    • /
    • pp.131-136
    • /
    • 2023
  • We developed a method to measure the concentration of highly concentrated colored samples using color coordinates. We present a color analysis to estimate the concentration of highly concentrated binary solutions with an empirical function and apply it to estimate the kinetics of a catalytic irreversible reaction of resazurin to resorufin. The developed method enabled one to measure the concentration of solutions whose range of concentrations is nonlinear and beyond the limit of UV-vis spectroscopic measurement directly without dilution.

Anti-influenza Compounds Isolated from Descurainia sophia Seeds

  • Woo Seung Yang;Choong Je Ma
    • Natural Product Sciences
    • /
    • v.29 no.2
    • /
    • pp.113-119
    • /
    • 2023
  • Descurainia sophia seeds methanol extract showed significant anti-influenza activity and we tried to isolate anti-influenza compounds from the D. sophia extract. D. sophia seeds were extracted with 80% methanol and fractionated with n-hexane, ethyl acetate, CHCl3 and n-butanol. The anti-influenza activity of each fraction was assessed using sulforhodamine B (SRB) method in A549 cells, human-derived lung cancer cells. The ethyl acetate and CHCl3 fractions showed the most potent anti-influenza activity. Seven compounds were isolated from CHCl3 fraction and identified 1-decanol (1), 2-(3,4-dihydroxy-2-methylenebutoxy)-6-(hydroxymethyl)tetrahydro-2H-pyran-3,4,5-triol (2), daucosterol (3), isorhamnetin (4), quercetin (5), sinapic acid (6), and helveticoside (7) by spectroscopic data such as UV, IR, 1H-NMR, 13C-NMR and mass spectroscopy. Anti-influenza activities of isolated compounds were evaluated using SRB method in A549 cells. Compounds 3, 4 and 7 had significant anti-influenza activity in a dose-dependent manner.

Feasibility of $In$ $vivo$ Proton Magnetic Resonance Spectroscopy for Lung Cancer (폐암의 생체 수소자기공명분광법의 실행가능성)

  • Yoon, Soon-Ho;Park, Chang-Min;Lee, Chang-Hyun;Song, In-Chan;Lee, Hyun-Ju;Goo, Jin-Mo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.40-46
    • /
    • 2012
  • Purpose : To investigate the feasibility of in vivo proton magnetic resonance spectroscopy (MRS) for evaluation of lung cancer. Materials and Methods: This prospective study was approved by the institutional review board of our hospital and informed consent was obtained in all patients. Ten patients (7 men, 3 women; mean age, 64.4) with pathologicallyproven lung cancer (mean, 56.8 mm; range, 44-77 mm) were enrolled to 1.5 T MRS using a single-voxel respiration-triggered point-resolved spectroscopic sequence. Technical success rate and the reason of technical failure, if any, were investigated. Results: Out of 10 lung cancers, analyzable MRS spectra were obtained in 8 tumors (technical success rate, 80%). Two MRS datasets were not able to be analyzed due to serious baseline distortion. Choline and lipid signals were detected as major metabolites in analyzable MRS spectra. Conclusion: In vivo proton MRS method using a single-voxel respiration-triggered point-resolved spectroscopic sequence is feasible in obtaining the MR spectra of lung cancer because these spectra were analyzable and high success rate was shown in our study although there was the limitation of small patient group.