• Title/Summary/Keyword: Spectral tarp

Search Result 6, Processing Time 0.021 seconds

VICARIOUS GROUND CALIBRATION OF AIRBORNE MULTISPECTRAL SCANNER (AMS) DATA BASED ON FIELD CAMPAIGN

  • Lee, Kwang-Jae;Kim, Yong-Seung;Han, Jong-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.184-187
    • /
    • 2006
  • The radiometric correction is prerequisite to derive both land and ocean surface properties from optical remote sensing data. Radiometric calibration of remotely sensed data has traditionally been accomplished by means of vicarious ground calibration techniques. The purpose of this study is to calibrate the radiometric characteristic of Airborne Multispectral Scanner (AMS) by field campaign. In order to calibrate the AMS data, four different spectral tarps which are 3.5%, 23%, 35%, and 53% were validated by GER-3700 that is the surface reflectance measurement equipment and were utilized. After validation of the spectral tarps, each reflectance from the spectral tarps was compared with Digital Number (DN) value of AMS. There was very high correlation between tarp reflectance and DN value of AMS so that radiometric calibration of AMS data has been accomplished by those results. The calibrated AMS data were validated with in-situ measured reflectance data from artificial and natural target. Also QuickBird image data were used for verifying the results of AMS radiometric calibration. This presentation discusses the results of the above tests.

  • PDF

A Comparative Study of Absolute Radiometric Correction Methods for Drone-borne Hyperspectral Imagery (드론 초분광 영상 활용을 위한 절대적 대기보정 방법의 비교 분석)

  • Jeon, Eui-ik;Kim, Kyeongwoo;Cho, Seongbeen;Kim, Shunghak
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.203-215
    • /
    • 2019
  • As hyperspectral sensors that can be mounted on drones are developed, it is possible to acquire hyperspectral imagery with high spatial and spectral resolution. Although the importance of atmospheric correction has been reduced since imagery of drones were acquired at a low altitude,studies on the conversion process from raw data to spectral reflectance should be done for studies such as estimating the concentration of surface materials using hyperspectral imagery. In this study, a vicarious radiometric calibration and an atmospheric correction algorithm based on atmospheric radiation transfer model were applied to hyperspectral data of drone and the results were compared and analyzed. The vicarious calibration method was applied to an empirical line calibration using the spectral reflectance of a tarp made of uniform material. The atmospheric correction algorithm used ATCOR-4 based Modran-5 that was widely used for the atmospheric correction of aerial hyperspectral imagery. As a result of analyzing the RMSE of the difference between the reference reflectance and the correction, the vicarious calibration using the tarp in a single period of hyperspectral image was the most accurate, but the atmospheric correction was possible according to the application purpose of using hyperspectral imagery. If the correction process of normalized spectral reflectance is carried out through the additional vicarious calibration for imagery from multiple periods in the future, accurate analysis using hyperspectral drone imagery will be possible.

Study on Reflectance and NDVI of Aerial Images using a Fixed-Wing UAV "Ebee"

  • Lee, Kyung-Do;Lee, Ye-Eun;Park, Chan-Won;Hong, Suk-Young;Na, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.731-742
    • /
    • 2016
  • Recent technological advance in UAV (Unmanned Aerial Vehicle) technology offers new opportunities for assessing crop situation using UAV imagery. The objective of this study was to assess if reflectance and NDVI derived from consumer-grade cameras mounted on UAVs are useful for crop condition monitoring. This study was conducted using a fixed-wing UAV(Ebee) with Cannon S110 camera from March 2015 to March 2016 in the experiment field of National Institute of Agricultural Sciences. Results were compared with ground-based recordings obtained from consumer-grade cameras and ground multi-spectral sensors. The relationship between raw digital numbers (DNs) of UAV images and measured calibration tarp reflectance was quadratic. Surface (lawn grass, stairs, and soybean cultivation area) reflectance obtained from UAV images was not similar to reflectance measured by ground-based sensors. But NDVI based on UAV imagery was similar to NDVI calculated by ground-based sensors.

Construction and Data Analysis of Test-bed by Hyperspectral Airborne Remote Sensing (초분광 항공원격탐사 테스트베드 구축 및 시험자료 획득)

  • Chang, Anjin;Kim, Yongil;Choi, Seokkeun;Han, Dongyeob;Choi, Jaewan;Kim, Yongmin;Han, Youkyung;Park, Honglyun;Wang, Biao;Lim, Heechang
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.2
    • /
    • pp.161-172
    • /
    • 2013
  • The construction of hyperspectral test-bed dataset is essential for the effective performance of hyperspectral image for various applications. In this study, we analyzed the technical points for generating of optimal hyperspectral test-bed site for hyperspectral sensors and the efficiency of hyperspectral test-bed site. In this regard regions we analyzed existing construction techniques for generating test-bed site in domestic and foreign, and designed the test-bed site to acquire images from the airborne hyperspectral sensor. To produce a reference data from the image of constructed test-bed site, this study applied vicarious correction as a pre-processing and analyzed its efficiency. The result presented that it was ideal to use tarp for the vicarious correction, but it is possible to use the materials with constant spectral reflectance or with relatively low variance of spectral reflectance. The test-bed data taken in this study can be employed as the reference of domestic and foreign studies for hyperspectral image processing.

Diurnal Change of Reflectance and Vegetation Index from UAV Image in Clear Day Condition (청천일 무인기 영상의 반사율 및 식생지수 일주기 변화)

  • Lee, Kyung-do;Na, Sang-il;Park, Chan-won;Hong, Suk-young;So, Kyu-ho;Ahn, Ho-yong
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.735-747
    • /
    • 2020
  • Recent advanced UAV (Unmanned Aerial Vehicle) technology supply new opportunities for estimating crop condition using high resolution imagery. We analyzed the diurnal change of reflectance and NDVI (Normalized Difference Vegetation Index) in UAV imagery for crop monitoring in clear day condition. Multi-spectral images were obtained from a 5-band multi-spectral camera mounted on rotary wing UAV. Reflectance were derived by the direct method using down-welling irradiance measurement. Reflectance using UAV imagery on calibration tarp, concrete and crop experimental sites did not show stable by time and daily reproducible values. But the CV (Coefficient of Variation) of diurnal NDVI on crop experimental sites was less than 5%. As a result of comparing NDVI at the similar time for two day, the daily mean average ratio of error showed a difference of 0.62 to 3.97%. Therefore, it is considered that NDVI using UAV imagery can be used for time series crop monitoring.

Effects of Halogen and Light-Shielding Curtains on Acquisition of Hyperspectral Images in Greenhouses (온실 내 초분광 영상 취득 시 할로겐과 차광 커튼이 미치는 영향)

  • Kim, Tae-Yang;Ryu, Chan-Seok;Kang, Ye-seong;Jang, Si-Hyeong;Park, Jun-Woo;Kang, Kyung-Suk;Baek, Hyeon-Chan;Park, Min-Jun;Park, Jin-Ki
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.306-315
    • /
    • 2021
  • This study analyzed the effects of light-shielding curtains and halogens on spectrum when acquiring hyperspectral images in a greenhouse. The image data of tarp (1.4*1.4 m, 12%) with 30 degrees of angles was achieved three times with four conditions depending on 14 heights using the automatic image acquisition system installed in the greenhouse at the department of Southern Area of National Institute of Crop Science. When the image was acquired without both a light-shielding curtain and halogen lamp, there was a difference in spectral tendencies between direct light and shadow parts on the base of 550 nm. The average coefficient of variation (CV) for direct light and shadow parts was 1.8% and 4.2%, respective. The average CV value was increased to 12.5% regardless of shadows. When the image was acquired only used a halogen lamp, the average CV of the direct light and shadow parts were 2 .6% and 10.6%, and the width of change on the spectrum was increased because the amount of halogen light was changed depending on the height. In the case of shading curtains only used, the average CV was 1.6%, and the distinction between direct light and shadows disappeared. When the image was acquired using a shading curtain and halogen lamp, the average CV was increased to 10.2% because the amount of halogen light differed depending on the height. When the average CV depending on the height was calculated using halogen and light-shielding curtains, it was 1.4% at 0.1m and 1.9% at 0.2 m, 2 .6% at 0.3m, and 3.3% at 0.4m of height, respectively. When hyperspectral imagery is acquired, it is necessary to use a shading curtain to minimize the effect of shadows. Moreover, in case of supplementary lighting by using a halogen lamp, it is judged to be effective when the size of the object is less than 0.2 m and the distance between the object and the housing is kept constant.