• Title/Summary/Keyword: Spectral range

Search Result 948, Processing Time 0.031 seconds

Analysis of structure and properties of wavelength demultiplexing using photopolymer phase grating (포토폴리머 위상 격자를 이용한 파장 역다중화 구조 및 특성 분석)

  • Choi, Won-Jun;An, Jun-Won;Kim, Nam;Lee, Kwon-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • A new wavelength demultiplexing scheme using holographic volume phase grating formed in photopolymer is proposed and demonstrated. Through the analysis and experiments of the design parameters such as wavelength selectivity, operating spectral range, spatial channel distance and spatial intensity distribution of each channel, we proved that the proposed demultiplexing scheme is promising for wavelength division multiplexing (WDM). From the experimental results, the 3 dB bandwidth of 0.21nm and the crosstalk level of 26 dB for a 0.8 nm channel spacing are observed.

Fabrication of $CaSO_4$ : Tm, $CaSO_4$ : Tm-PTFE TLD Radiation Sensors and Its Characteristics ($CaSO_4$ : Tm, $CaSO_4$ : Tm-PTFE TLD 소자의 제작과 특성에 관한 연구)

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.107-115
    • /
    • 1993
  • In this study, to develop highly sensitive radiation sensors, $CaSO_4$ : Tm phosphors and its disc-type TLD elements embedded PTFE(polytetrafluoroethylene) are fabricated. The highest sensitivity of $CaSO_4$ : Tm phosphors is obtained when phosphors have been doped with 0.5mol % Tm and sintered in atmosphere at $600^{\circ}C$ for two hours. Fabricated disc-type elements are made from a homogeneous mixture of phosphors and PTFE powder. They are first cold-pressed and then polymerized at $370^{\circ}C$ in air for one hour. The dose dependence of the prepared $CaSO_4$ : Tm TLD radiation sensors is linear within the range of $100{\mu}Gy{\sim}10Gy$ for X-rays and ${\gamma}-rays$. The response of $CaSO_4$ : Tm to 30keV X-rays is ten times higher than that of 1.25MeV $^{60}Co\;{\gamma}-rays$. The fading rate of the main peak is about 2% per a month. The spectral peaks of TL emission spectrum are at about 350nm and 475nm. The $CaSO_4$ : Tm TLD radiation sensors prepared in this work may be used as radiation dosimeter for personal and environmental monitoring because of their high sensitivity and little fading.

  • PDF

MIR LUMINOSITY FUNCTION OF GALAXIES IN THE NEP-WIDE FIELD

  • Kim, Seong Jin;Lee, Hyung Mok;Jeong, Woong-Seob;NEP team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.263-265
    • /
    • 2017
  • We present the mid-infrared (MIR) luminosity function (LF) of local (z < 0.3) star-forming (SF) galaxies in the North Ecliptic Pole (NEP) field. This work is based on the NEP-Wide point source catalogue and the spectroscopic redshift (z) data for ~ 1700 galaxies obtained by the optical follow-up survey with MMT/Hectospec and WIYN/Hydra. The AKARI's continuous $2-24{\mu}m$ coverage and the spectroscopic redshifts enable us to determine the spectral energy distribution (SED) in the mid-infrared and derive the luminosity functions of galaxies. Our $8{\mu}m$ LF finds good agreements with the results from SWIRE field over the wide luminosity range, while showing significant difference from the NOAO deep data in the faint end. The comparison with higher-z sample shows significant luminosity evolution from z > 0.3 to local universe. $12{\mu}m$ LF also shows a clear indication of luminosity evolution.

Measurement of electro-physiological changes in the brain exposed to eletromagnetic wave radiation (전자파에 노출된 생체두부의 전기생리적 변화의 측정에 관한 연구)

  • 이준하;신현진;이상학;유동수;이무영;김성규
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.35-43
    • /
    • 1994
  • Electromagnetic wave may induce effect and damage on the bio-body, either by electric fields of magnetic fields. We measure electrophysiological changs in rabbit's brain exposed to 2.45GHz micro wave(power density 40mW/cm$^2$) which distance 30cm from the source. In order to process the bio-electrical signal (EEG), used pre-amplifier module with self-made and Digtal analyzer computer system. Spectal analysis of the EEG showed variable power in the frequency range(1~30Hz) through each exposure time(10min, 20min, 30min) before and after. In effectively measured by the bio-electrical signal processing and can found threshold of minmal permissible exposure and lethal exposure.

  • PDF

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Rapid Prediction of Amylose Content of Polished Rice by Fourier Transform Near-Infrared Spectroscopy

  • Lee, Jin-Cheol;Yoon, Yeon-Hee;Kim, Sun-Min;Pyo, Byong-Sik;Hsieh, Fu-Hung;Kim, Hak-Jin;Eun, Jong-Bang
    • Food Science and Biotechnology
    • /
    • v.16 no.3
    • /
    • pp.477-481
    • /
    • 2007
  • Fourier transform near-infrared (FT-NIR) spectroscopy and partial least squares (PLS) regression were used to predict the amylose content of polished rice. Spectral reflectance data in a wavelength range of 1,000 to 2,500 nm were obtained with a commercial spectrophotometer for 60 different varieties of Korean rice. For a comparison of this spectroscopic method to a standard chemical analysis, the amylose contents of the tested rice samples were determined by the iodine-blue colorimetric method. The highest correlation for the rice amylose ($R^2=0.94$, standard error of prediction=0.20% amylose content) was obtained when using the FT-NIR spectrum data pre-treated with normalization, the first derivative, smoothing, and scattering correction.

Development of Terra MODIS data pre-processing system on WWW

  • Takeuchi, W.;Nemoto, T.;Baruah, P.J.;Ochi, S.;Yasuoka, Y.
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.569-572
    • /
    • 2002
  • Terra MODIS is one of the few space-borne sensors currently capable of acquiring radiometric data over the range of view angles. Institute of Industrial Science, University of Tokyo, has been receiving Terra MODIS data at Tokyo since May 2001 and Asian Institute of Technology at Bangkok since May 2001. They can cover whole East Asia and is expected to monitor environmental changes regularly such as deforestation, forest fires, floods and typhoon. Over eight hundred scenes have been archived in the storage system and they occupy 2 TB of disk space so far. In this study, MODIS data processing system on WWW is developed including following functions: spectral subset (250m, 500m, 1000m channels), radiometric correction to radiance, spatial subset of geocoded data as a rectangular area with latitude-longitude grid system in HDF format, generation of a quick look file in JPEG format. Users will be notified just after all the process have finished via e-mail. Using this system enables us to process MODIS data on WWW with a few input parameters and download the processed data by FTP access. An easy to use interface is expected to promote the use of MODIS data. This system is available via the Internet on the following URL from September 1 2002, "http : //webmodis.iis.u-tokyo.ac.jp/".

  • PDF

Development of the Algorithm for Optimizing Wavelength Selection in Multiple Linear Regression

  • Hoeil Chung
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • A convenient algorithm for optimizing wavelength selection in multiple linear regression (MLR) has been developed. MOP (MLP Optimization Program) has been developed to test all possible MLR calibration models in a given spectral range and finally find an optimal MLR model with external validation capability. MOP generates all calibration models from all possible combinations of wavelength, and simultaneously calculates SEC (Standard Error of Calibration) and SEV (Standard Error of Validation) by predicting samples in a validation data set. Finally, with determined SEC and SEV, it calculates another parameter called SAD (Sum of SEC, SEV, and Absolute Difference between SEC and SEV: sum(SEC+SEV+Abs(SEC-SEV)). SAD is an useful parameter to find an optimal calibration model without over-fitting by simultaneously evaluating SEC, SEV, and difference of error between calibration and validation. The calibration model corresponding to the smallest SAD value is chosen as an optimum because the errors in both calibration and validation are minimal as well as similar in scale. To evaluate the capability of MOP, the determination of benzene content in unleaded gasoline has been examined. MOP successfully found the optimal calibration model and showed the better calibration and independent prediction performance compared to conventional MLR calibration.

SPECIAL CONSIDERATION ON THE RADARSAT REPEAT-PASS SAR INTERFEROMETRY

  • Kim, Sang-Wan;Won, Joong-Sun;Moon, Wooil-M.
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.474-478
    • /
    • 1999
  • SAR interferometry (InSAR) using the space-borne Synthetic Aperture Radar (SAR) have recently become one of the most effective tools monitoring surface changes caused by landslides, earthquakes, subsidences or volcanic eruption. This study focuses on examining the feasibility of InSAR using the RADARSAT data. Although the RABARSAT SAR with its high resolution and variable incidence angle has several advantages for repeat-pass InSAR, it has two key limitations: first, the orbit is not precisely known; and second, RADARSAT's 24-day repeat pass interval is not very favourable for retaining useful coherence. In this study, two pairs of RADARSAT data in the Nahanni area, NWT, Canada have been tested. We will discuss about the special consideration required on the interferometric processing steps specifically for RADARSAT data including image co-registration, spectral filtering in both azimuth and range, estimation of the interferometric baseline, and correction of the interferogram with respect to the "flat earth" phase contribution. Preliminary results can be summarized as: i) the properly designed azimuth filter based upon the antenna characteristic improves coherence considerably if difference in Doppler centroid of the two images is relatively large; ii) the co-registration process combined by fringe spectrum and amplitude cross-correlation techniques results in optimal matching; iii) the baseline is not always possible to be estimated from the definitive orbit information.

  • PDF

Determination of Instantaneous Frequency By Continuous Wavelets Ridge (연속 웨이브렛 Ridge를 이용한 순간주파수 결정)

  • Kim, Tae-Hyung;Yoon, Dong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.8-15
    • /
    • 2005
  • The analysis of Rader signal that have non-linearity variable phase is signal that contact easily in several fields such as radar, telecommunication, seismic, sonar and biomedical applications. In generally, Non-stationary signal means that spectral characteristics are varying with time and instantaneous frequency is only one frequency or narrow range of frequencies varying as a function of time. Therefore, Instantaneous frequency is vary important variable that understanding physical characteristic of signal. This paper was describes continuous wavelet transform to determine instantaneous frequency at non-staionary signal and compare to existing method. When white noise or various frequency is overlapped each other in sign, existing method was can not decide corrected instantaneous frequency, but when used continuous wavelet transform, very well decide correctly frequency regardless of component of signal.