• 제목/요약/키워드: Specimen size

검색결과 1,390건 처리시간 0.026초

보정계수 및 시험체두께가 포러스콘크리트의 기초물성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Properties of Porous Concrete according to Correction Factor and Specimen Thickness)

  • 김재환;이성일;장종호;오시덕;박정호;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.55-58
    • /
    • 2002
  • This study is to analyze the influence of correction factor and specimen thickness on the fundamental properties of porous concrete. Results of this study were shown as follows; 1) As correction factor decrease, compaction time according to correction factor and specimen thickness decrease. Also, though correction factor is same, as specimen thickness increase, compaction time increase. So It mutt be considered that the influence of compaction time according to correction factor and specimen thickness. 2) As correction factor decrease, difference of measured thickness and designed thickness according to correction factor and specimen thickness decrease. Also, correction factor of aggregate of 10~l5mm is smaller than that of 5~l0mm. So It must be considered that the influence of correction factor according to size of aggregate.

  • PDF

Effect of specimen geometry and specimen preparation on the concrete compressive strength test

  • Aslani, Farhad;Maia, Lino;Santos, José
    • Structural Engineering and Mechanics
    • /
    • 제62권1호
    • /
    • pp.97-106
    • /
    • 2017
  • This paper discusses an experimental programme that was carried out to study the effects of specimen size-shape and type of moulds on the compressive strength of concrete. For this purpose, cube specimens with 150 mm dimensions, cylinder specimens with $150{\times}300mm$ dimensions, and prism specimens with $150{\times}150{\times}375mm$ dimensions were prepared. The experimental programme was carried out with several concrete compositions belonging to strength classes C20/25, C25/30, C30/37, C40/50 and C60/75. Furthermore, the test results were curve-fitted using the least squares method to obtain the new parameters for the modified size effect law.

열화된 1Cr-1Mo-0.25V강의 DBTT 크기효과 보정에 관한 연구 (Normalization of DBTT Size Effect far Aged 1Cr-lMo-0.25V Steel)

  • 남승훈;김엄기;이대열
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.2109-2115
    • /
    • 2001
  • Miniaturized specimen technology is useful to characterize the mechanical behavior when it is difficult to sample the material enough for the test. In this study, two kinds of miniaturized Charpy impact specimens(i.e., miniaturized specimen with side groove and without side groove) of aged 1Cr- lMo-0.25V steel were prepared and tested. The relationship between the extent of degradation in terms of ductile brittle transition temperature(DBTT) and the fracture stress of 1Cr-1Mo-0.25V steel was established. The fracture stress obtained from miniaturized specimen without side groove turned out to be linearly related with the DBTT of standard specimen. Therefore the fracture toughness of aged turbine rotor steel might be evaluated by the fracture stress. In addition, the correlation between DBTT of standard specimen and that of miniaturized specimen was investigated. As the results of normalizing DBTT by maximum elastic tensile stress, the normalized DBTT of miniaturized specimen without side groove allows one to estimate that of standard specimen.

Determination of double-K fracture parameters of concrete using split-tension cube test

  • Kumar, Shailendra;Pandey, S.R.
    • Computers and Concrete
    • /
    • 제9권2호
    • /
    • pp.81-97
    • /
    • 2012
  • This paper presents development of double-K fracture model for the split-tension cube specimen for determining the unstable fracture toughness and initial cracking toughness of concrete. There are some advantages of using of split-tension cube test like compactness and lightness over the existing specimen geometries in practice such as three-point bend test, wedge splitting test and compact tension specimen. The cohesive toughness of the material is determined using weight function having four terms for the split-tension cube specimen. Some empirical relations are also suggested for determining geometrical factors in order to calculate stress intensity factor and crack mouth opening displacement for the same specimen. The results of double-K fracture parameters of split-tension cube specimen are compared with those obtained for compact tension specimen. Finally, the influence of the width of the load-distribution of split-tension cube specimen on the double-K fracture parameters for laboratory size specimens is investigated. The input data required for determining double-K fracture parameters for both the specimen geometries are obtained using well known version of the Fictitious Crack Model.

CT시험편의 크기 변화에 따른 파괴저항곡선의 변화 (Variation of the Fracture Resistance Curve with the Change of a Size in the CT Specimen)

  • 석창성;김수용
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2963-2971
    • /
    • 2000
  • In order to obtain more realistic fracture resistance curve, research is currently underway to introduce new parameter and to quantify the constraint effect. The objective of this study is to investigate the relationship between the constraint effect of a size(plane size and thickness) and the fracture resistance curve. In this paper fracture toughness tests were performed with various plane size and various thickness of specimens in two materials. The test results showed that the effects of plane size in th4 J-R curve were significant and the curve was risen with an increase in plane size. However, relatively weak influence was observed form the change of the specimen thickness and size. The stress fields near the crack tip of th specimen is close to the HRR field according to increasing the plane size and Q stress appears different value according to material properties and the plane size.

복합하중을 받는 샌드위치 시편의 응력분포에 미치는 시편 형상의 영향 (Effects of Specimen Geometry on Stress Distribution in Sandwich Specimen Under Combined Loads)

  • 박수경;홍성태
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1587-1592
    • /
    • 2010
  • 복합하중 하에서의 샌드위치 시편내의 응력분포에 시편의 형상과 하중조건이 미치는 영향을 수치해석을 통하여 고찰하였다. 상용 유한요소해석 프로그램인 NASTRAN 을 사용하여 세 종류의 형상계수를 가지는 시편들에 대하여 평면변형률, 2 차원 해석을 수행하였으며, 각각의 시편에 대하여 각각 다른 복합변위각을 가지는 네 종류의 복합변위를 적용하였다. 수치해석의 결과는 복합변위각이, 즉 전단변위의 수직변위에 대한 상대적인 크기가, 응력 불균일분포영역의 크기에 미치는 영향이 전단응력과 폰 미세스(von Mises)응력의 경우에만 나타나고 수직응력의 경우에는 나타나지 않음을 보여준다. 또한 복합변위각이 증가함에 따라 전단응력의 불균일분포영역의 크기는 감소함에 비해서 폰 미세스 응력의 불균일분포영역의 크기는 증가한다. 추가로, 형상계수가 증가함에 따라, 즉, 시편의 길이의 높이에 대한 상대적 크기가 커질수록, 복합변위 하에서의 응력 불균일분포영역의 크기는 현격하게 감소한다.

소형 창문의 차음성능 측정에 관한 고찰 (Measurement of sound Insulation of small-size windows)

  • 김상렬;강현주;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.942-945
    • /
    • 2006
  • In order to measure the sound transmission loss(STL) of a test specimen such as windows, which is smaller than the test opening, a special partition is built into the test opening and the specimen is placed in that partition. This paper discusses how the measured STL is changed by the partition when a small-size window of high sound insulation is mounted. Theoretical and experimental investigations are carried out to quantify the effect of the filler wall. The results reveal that the smaller the window size is, the higher sound insulation performance of the filler wall is required in order to measure the accurate STL of the specimen. It is found that the insufficient sound insulation of the filler wall leads to the lower measured value of the window's STL.

  • PDF

나노 인장시험을 위한 압축 시험기용 인장시편 제작에 관한 연구 (Fabrication of Nano-Size Specimens for Tensile Test Employing Nano-Indentation Device)

  • 임태우;양동열
    • 한국정밀공학회지
    • /
    • 제32권10호
    • /
    • pp.911-916
    • /
    • 2015
  • In the nano/micro scale, material properties are dependent on the size-scale of a structure. However, conventional micro-scale tensile tests have limitations to obtain reliable values of nano-scale material properties owing to residual stress and elastic slippage in the gripping/aligning process. The indenter-driven nano-scale tensile test provides prominent advantages simple testing device, high-quality nano-scale metallic specimen with negligible residual stress. In this paper, two-types of specimens (a specimen with multi-testing parts and a specimen with a single-testing part) are discussed. Focused ion beam (FIB) is employed to fabricate a nano-scale specimen from a thin nickel film. Using the specimen with a single-testing part, we obtained a nano-scale stress-strain curve of electroplated nickel film.

한국형 발사체 적용 대형 박판 배관 시편 제작 및 성능 평가 (Manufacturing and Performance Evaluation on Specimen pipes with Large Size Diameter and Thin Thickness for KSLV-II)

  • 이한주;이정호;오승협
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.81-86
    • /
    • 2013
  • 본 연구에서는 다양한 발사체 추진기관 공급계 배관 자재 중 STS 300 계열의 금속보다 강도가 높고 용접성이 우수할 것이라고 판단되는 21-6-9 합금소재를 이용하여 산화제 주배관의 시편을 제작 하였다. 제작된 시편은 내압 시험을 수행하여 요구되는 내압 강도를 유지할 수 있는지를 확인하였다.

Effects of loading frequency and specimen size on the liquefaction resistance of clean sand

  • Sung-Sik Park;Dong-Eun Lee;Dong-Kiem-Lam Tran
    • Geomechanics and Engineering
    • /
    • 제37권2호
    • /
    • pp.123-133
    • /
    • 2024
  • This study investigates the effects of loading frequency (f) and specimen size on the liquefaction resistance of clean sand. A series of cyclic direct simple shear tests were conducted on Jumunjin sand with varying consolidated relative densities (40% and 80%), f values (0.05, 0.10, and 0.20 Hz), and diameter to height (D/H) ratios (3.63, 3.18, 2.82, and 2.54). The results demonstrated the significant influence of f and D/H ratio on the number of cycles to liquefaction (Ncyc-liq) and the cyclic resistance ratio (CRR15). It was observed that increasing f linearly increased Ncyc-liq. Increasing the specimen height also led to higher Ncyc-liq values irrespective of the f or relative density. Moreover, a positive correlation between CRR15 and f indicated that higher f yielded higher CRR15. This relationship was more pronounced in dense sand than in loose sand. Specimen height also significantly affected CRR15, with increasing the specimen height resulting in higher CRR15 values. Furthermore, the effect of f on CRR15 was less significant compared to the influence of specimen height. The effect of f on the normalized cyclic resistance ratio (NCRR) was relatively negligible for loose sand but more substantial for dense sand depending on the D/H ratio. Data analysis revealed that the NCRR generally decreases as the D/H ratio increases. An interpolation formula was provided to calculate the NCRR based on the D/H ratio regardless of the f and relative density.