• Title/Summary/Keyword: Specific material removal rate

Search Result 31, Processing Time 0.024 seconds

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

A Study on the Grinding of Titanium Alloy Part 1 : Grinding force, Specific grinding energy, Surface roughness, G-ratio (티타늄 합금의 연삭에 관한 연구 Part 1: 연삭력, 비연삭에저니, 표면거칠기 , 연삭비)

  • Kim, S. H.;Lim, J. G.;Ha, S. B.;Choi, H.;lee, J. C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.870-874
    • /
    • 2000
  • This investigation reports the grinding characteristics of titanium alloy(Ti-6Al-4V). Grinding experiments were performed at various grinding conditions and the grinding forces and specific grinding energies were measured to investigate the grindability of titanium alloy with the three different wheels including Diamond, Green carbide and Alumina. To investigate the grinding characteristics of titanium alloy grinding force, force-ratio, specific grinding energy and grinding -ratio, were measured. Surface roughness was also measured with tracer and the ground surfaces were observed with SEM. Force-ratio of grinding of titanium alloy was very lower than that of grinding of SKD-11. Specific grinding energy are almost five times larger and rougher surface was obtained in titanium grinding.

  • PDF

Effects of Heavy Metals on the Beware Treatment Process by Water Hyacinth (중금속이 수생히야신스(부레옥잠)를 이용한 하수처리 공정에 미치는 영향)

  • 정재욱;유홍일;유재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.110-119
    • /
    • 1994
  • The objective of the this study was to evaluate the effects of heavy metals on the sewage treatment process designed to remove organic material and nutrients using Water- hyacinth ( Eichhornia crassipes ). Batch experiments were carried out using domestic sewage spiked with different level of heavy metal mixtures ( Cd, Pb and Cu ). The specific growth rates of Water- hyacinth ranged from 0.0008 to 0.0015 1/day( operated at water temperatures of 22 ∼30$\circ $c ) and increased as the concentration of heavy metals decreased. The test result showed that the permissible maximum concentrations Cd, Pb and Cu for the growth of Water- hyacinth were 0.5, 1, and 6 mg/ℓ respectively. Under these maximum permissible heavy metal loads, removal rate of organic material, nitrogen and phosphorus were 85%,75% and 75% , respectively, during 40days of the test period.

  • PDF

A Study on the Surface Grinding Machining Characteristics of FC200 Material (FC200 소재의 평면연삭 가공특성에 관한 연구)

  • Yang, Dong-Ho;Lee, Sang-Hyeop;Cha, Seung-Hwan;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.36-43
    • /
    • 2022
  • Automobile brake discs are a major part of automobiles that are directly related to driver safety, and prevention of judder and squall noise is very important. This phenomenon occurs for complex reasons such as the precision and assembly of the brake module, and the material of the brake disc. The purpose of this study is to analyze the effect of the grinding wheel's grain size on the grinding conditions when machining cast iron, the material of the brake disc, and to derive the optimal grinding conditions through this.

A Study on the Machining Characteristics of CVD-SiC (CVD-SiC 소재의 가공 특성에 관한 연구)

  • Park, Hwi-Keun;Lee, Won-Seok;Kang, Dong-Won;Park, In-Seung;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.40-46
    • /
    • 2017
  • A plasma gas control apparatus for semiconductor plasma etching processes securely holds a cathode for forming a plasma, confines the plasma during the plasma etching process, and discharges gas after etching. It is a key part of the etching process. With the advancement of semiconductor technology, there is increasing interest in parts for semiconductor manufacturing that directly affect wafers. Accordingly, in order to replace the plasma gas control device with a CVD-SiC material superior in mechanical properties to existing SiCs (Sintered-SiC, RB-SiC), a study on the grinding characteristics of CVD-SiC was carried out. It is confirmed that the optimal grinding condition was obtained when the result table feed rate was 2 m/min and the infeed depth was $5{\mu}m$.

The Removal Characteristics of Organic Matter in Drinking Water Source by Coagulation and Ultrafiltration Process (응집 및 한외여과 공정에 의한 상수원수의 유기물질 제거 특성)

  • Kim, Hyun-Sik;Lim, Ji-Young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.5-10
    • /
    • 2018
  • This study was evaluated the characteristics of organic materials in the water source and the removal characteristics of organic materials by ultrafiltration including mixing and coagulation process. As a results of the study, it was found that the total organic carbon in the water source was mostly caused by the dissolved organic materials. As the specific ultraviolet absorbance value of the raw water was low, we found the soluble organic material has a high hydrophilic and low molecular material composition ratio. As a result of ultrafiltration experiment including mixing and coagulation process, the average removal rate of total organic carbon, dissolved organic carbon and ultraviolet absorbance at 254 were 37.9%, 30.3%, and 28.2%, respectively.

Geotrichum sp.를 이용한 biofiltration에서의 methyl ethyl ketone 제거

  • Choe, Jae-Heon;Park, Gyeong-Ran;O, Yeong-Suk;Choe, Seong-Chan
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.560-563
    • /
    • 2001
  • Geotrichum sp. MF01, isolated from oil-contaminated soil, utilized methyl ethyl ketone(MEK) as the sole source of carbon and energy. The strain MF01 showed a Michaelis-Menten kinetics on MEK, and the kinetic parameters determined for MEK degradation were; specific removal rate, $r_{max}$ = 0.14 $h^{-1}$; half-saturation constant, $K_m$ = 5.88 mM. The adsorption of MEK by heat-killed strain was 0.62 mg at 8.07 mg MEK indicating that the degradation was the primary removal mechanism over adsorption. Biodegradation of MEK was studied in a biofilter using perlite, vermiculite 0:1, v/v) as supporting material. During 57 days of biofilter operation, $^3h^{-1}$.

  • PDF

Application of surface modified sericite to remove anionic dye from an aqueous solution

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.312-319
    • /
    • 2017
  • The treatment of dyeing wastewater is not easy because dyes are mainly aromatic, heterocyclic compounds. The most effective technologies and methods to treat dyeing wastewater are costly and involve materials that are difficult to regenerate after use. Therefore, it is necessary to develop cost-effective, eco-friendly technologies to treat dyeing wastewater. The aim of this study was to investigate the removal of sulfur blue 11 (CI 53235) anionic dye using methyl esterified sericite (ME-sericite) adsorbents in an aqueous solution. The results are discussed in terms of the ME-sericite particle size, temperature, pH value and initial sorption rate according to the initial sulfur blue concentration. In addition, we analyzed the adsorption kinetics using a Pseudo-second-order model with the desorption and reusability. The methyl esterification caused a considerable increase in the specific surface area from 4.45 to $17.62m^2/g$. The ME-sericite adsorbents successfully removed > 98% of the sulfur dye in the aqueous solution. For the adsorption of 1 mg of sulfur dye, approximately 4.6 to 6.6 g/L ME-sericite were required. The desorption process was carried out by mixing a NaOH eluent to desorb 90.56% of the sulfur dye with 2 h of contact time. Thus, the ME-sericite is a promising adsorbent to treat dyeing wastewater due to its low dose requirement, high removal efficiency and inexpensive material.

Synthesis of Pd/Cu-Fe polymetallic nanoparticles for in situ reductive degradation of p-nitrophenol

  • Wenbin, Zhang;Lanyu, Liu;Jin, Zhao;Fei, Gao;Jian, Wang;Liping, Fang
    • Membrane and Water Treatment
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2022
  • With a small particle size, specific surface area and chemical nature, Pd/Cu-Fe nanocomposites can efficiently remove the organic compounds. In order to understand the applicability for in situ remediation of contaminated groundwater, the degradation of p-nitrophenol by Pd/Cu-Fe nanoparticles was investigated. The degradation results demonstrated that these nanoparticles could effectively degrade p-nitrophenol and near 90% of degradation efficiency was achieved by Pd/Cu-Fe nanocomposites for 120 min treatment. The efficiency of degradation increased significantly when the Pd content increased from 0.05 wt.% and 0.10 wt.% to 0.20 wt.%. Meanwhile, the removal percentage of p-nitrophenol increased from 75.4% and 81.7% to 89.2% within 120 min. Studies on the kinetics of p-nitrophenol that reacts with Pd/Cu-Fe nanocomposites implied that their behaviors followed the pseudo-first-order kinetics. Furthermore, the batch experiment data suggested that some factors, including Pd/Cu-Fe availability, temperature, pH, different ions (SO42-, PO43-, NO3-) and humic acid content in water, also have significant impacts on p-nitrophenol degradation efficiency. The recyclability of the material was evaluated. The results showed that the Pd/Cu-Fe nanoparticles have good recycle performance, and after three cycles, the removal rate of p-nitrophenol is still more than 83%.

A study on sanitary emprical for specific property removal of pollution material inter a water tank by ozone (오존을 이용한 수조속의 오염물질 제거특성에 관한 실험적 연구)

  • Lee, Kwan-young;Ahn, Seoung-Seop;Park, Sang-hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2002
  • In this study, the initial number of bacteria before ozone sterilizing shows 290 per $1m{\ell}$ in RUN 1 and RUN 2 equally, but the removal rate shows more than 50% in RUN 1, and 100% in RUN 2 respectively when ozone injection amount is $0.28mg/{\ell}$. It is regarded as a satisfactory result that E-coli concentration without ozone contact is 890, rapid removal effect of E-coli is observed in $0.28mg/{\ell}$ of ozone, and E-coli is removed perfectly in $0.84mg/{\ell}$ of ozone. It is thought that an excellent efficiency is obtained for vibrio alginolyticus because the initial number of bacteria before ozone contact is positive, but it is altered to negative after ozone contact. CODcr shows the tendency which is somewhat reduced as the ozone injection is increased, but the general effect is appeared not so much, and it is thought that the tendency is caused by the reason that sea water contains much salt which is estimated as a component of CODcr, therefore it is regarded that ozone contact has not an important effect on salinity. It is thought that the frequency of changing salt water in the fish preserve of a sliced raw fish restaurant can be reduced to under the standard because NTU of 7 days after sea water injection is 0.70 in the experiment of turbidity, hut more than 50% of turbidity removal efficiency is appeared at $0.28mg/{\ell}$ of ozone injection, and it shows 70% at $0.84mg/{\ell}$ of ozone injection in RUN 1 and RUN 2 commonly.

  • PDF