• Title/Summary/Keyword: Specific energy

Search Result 3,365, Processing Time 0.028 seconds

Renewable energy powered membrane systems: inorganic contaminant removal from Australian groundwaters

  • Richards, Laura A.;Richards, Bryce S.;Schafer, Andrea I.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.239-250
    • /
    • 2011
  • A photovoltaic powered ultrafiltration and reverse osmosis system was tested with a number of natural groundwaters in Australia. The objective of this study was to compare system performance at six remote field locations by assessing the impact of water composition and fluctuating energy on inorganic contaminant removal using a BW30-4040 membrane. Solar irradiance directly affected pressure and flow. Groundwater characteristics (including TDS, salts, heavy metals, and pH), impacted other performance parameters such as retention, specific energy consumption and flux. During continual system operation, retention of ions such as $Ca^{2+}$ and $Mg^{2+}$ was high (> 95%) with each groundwater which can be attributed to steric exclusion. The retention of smaller ions such as $NO_3{^-}$ was affected by weather conditions and groundwater composition, as convection/diffusion dominate retention. When solar irradiance was insufficient or fluctuations too great for system operation, performance deteriorated and retention dropped significantly (< 30% at Ti Tree). Groundwater pH affected flux and retention of smaller ions ($NO_3{^-}$ and $F^-$) because charge repulsion increases with pH. The results highlight variations in system performance (ion retention, flux, specific energy consumption) with real solar irradiance, groundwater composition, and pH conditions.

Prediction Model for Specific Cutting Energy of Pick Cutters Based on Gene Expression Programming and Particle Swarm Optimization (유전자 프로그래밍과 개체군집최적화를 이용한 픽 커터의 절삭비에너지 예측모델)

  • Hojjati, Shahabedin;Jeong, Hoyoung;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.651-669
    • /
    • 2018
  • This study suggests the prediction model to estimate the specific energy of a pick cutter using a gene expression programming (GEP) and particle swarm optimization (PSO). Estimating the performance of mechanical excavators is of crucial importance in early design stage of tunnelling projects, and the specific energy (SE) based approach serves as a standard performance prediction procedure that is applicable to all excavation machines. The purpose of this research, is to investigate the relationship between UCS and BTS, penetration depth, cut spacing, and SE. A total of 46 full-scale linear cutting test results using pick cutters and different values of depth of cut and cut spacing on various rock types was collected from the previous study for the analysis. The Mean Squared Error (MSE) associated with the conventional Multiple Linear Regression (MLR) method is more than two times larger than the MSE generated by GEP-PSO algorithm. The $R^2$ value associated with the GEP-PSO algorithm, is about 0.13 higher than the $R^2$ associated with MLR.

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

Specific Capacitance Characteristics of Electric Double Layer Capacitors with Phenol Based Activated Carbon Fiber Electrodes and Aqueous Electrolytes (페놀계 활성탄소섬유 전극과 수용성 전해질을 사용하는 전기이중층 캐패시터의 비축전용량 특성)

  • Kim, Jong Huy;An, Kay Hyeok;Shin, Kyung Hee;Ryoo, Min Woong;Kim, Dong Kuk
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.814-821
    • /
    • 1999
  • The specific capacitance characteristics of the electric double layer capacitors(ELDC) which were made of phenol based activated carbon fiber(ACF) electrodes. Also the effect of aqueous electrolytes on the cell performance has been investigated with respect to different specific surface areas of electrodes and different kinds of aqueous electrolytes. It has been shown that larger surface area and pore size, higher conductivity of electrodes, and higher ion mobility of electrolytes have better specific capacitances. It has been found that heat treatment at $1200^{\circ}C$ and $CO_2$ post-activation at $900^{\circ}C$ of the electrode are effective to improve the specific capacitance over 145F/g and 165F/g, respectively. The EDLC showed high efficiency and long cycle life over 30000 cycles.

  • PDF

Applicability Study of Reactor Design in Sewage Treatment Plant using Specific Oxygen Uptake Rate (SOUR을 이용한 하수처리시설 포기조 설계 적용에 관한 연구)

  • Joo, Hyun Jong;Kim, Sung Chul;Lee, Kwang Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.140-147
    • /
    • 2010
  • In existing design method for aeration tank water temperature was considered as governing variable for applying safety factor. This study tried a few new approach of aeration tank design using SOUR at various temperature conditions. Specific substrate utilization rate (U) and specific oxygen uptake rate (SOUR) both were analyzed at various temperature and SRT. The laboratory scale reactor was operated on various temperature ($10^{\circ}C$, $20^{\circ}C$, $25^{\circ}C$) and SRT (5day, 10day, 20day, 30day). In this study, SOUR tended to increase with the temperature increased. On the other hand, SOUR tended to decrease when SRT increased from 5 days to 30 days. Empirical equations were obtained SOUR=a/SRT+b and $SOUR=(a/m){\cdot}U+(b-a(n/m))$ from the relationship between SRT, U and SOUR. Empirical equations shows the possibility as a new design method for the aeration basin.

Reevaluation of Seismic Fragility Parameters of Nuclear Power Plant Components Considering Uniform Hazard Spectrum

  • Park, In-Kil;Choun, Young-Sun;Seo, Jeong-Moon;Yun, Kwan-Hee
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.586-595
    • /
    • 2002
  • The Seismic probabilistic risk assessment (SPRA) or seismic margin assessment (SMA) have been used for the seismic safety evaluation of nuclear power plant structures and equipments. For the SPRA or SMA, the reference response spectrum should be defined. The site-specific median spectrum has been generally used for the seismic fragility analysis of structures and equipments in a Korean nuclear power plant Since the site-specific spectrum has been developed based on the peak ground motion parameter, the site-specific response spectrum does not represent the same probability of exceedance over the entire frequency range of interest. The uniform hazard spectrum is more appropriate to be used in seismic probabilistic risk assessment than the site- specific spectrum. A method for modifying the seismic fragility parameters that are calculated based on the site-specific median spectrum is described. This simple method was developed to incorporate the effects of the uniform hazard spectrum. The seismic fragility parameters of typical NPP components are modified using the uniform hazard spectrum. The modification factor is used to modify the original fragility parameters. An example uniform hazard spectrum is developed using the available seismic hazard data for the Korean nuclear power plant (NPP) site. This uniform hazard spectrum is used for the modification of fragility parameters.

Plotting of 13 Kinds of Properties on Temperature-Entropy Chart of Air (공기의 온도-엔트로피 선도 상에서 13 종류의 물성치 작도)

  • Kim, Deok-Jin;Kim, Duck-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1191-1196
    • /
    • 2009
  • The T-s chart of air displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. In previous study, the software analyzing 31 kinds of values in water system and 32 kinds of values in air-conditioning system were developed. In this study, the software drawing 13 kinds of quantity of state on air properties as ideal gas and analyzing 25 kinds of values in any air system was developed. The 13 kinds of quantity of state on air properties are temperature, pressure, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, and velocity of sound, and the 25 kinds of values including 13 kinds are mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, reversible work, lost work, and relative humidity. The developed software can draw any range of chart and analysis any state or process on air system. Also, this supports various document-editing functions such as power point. We wish to this chart is a help to design, analysis, and education in air system field.

  • PDF

Study of neutron energy and directional distribution at the Beloyarsk NPP selected workplaces

  • Pyshkina, Mariia;Vasilyev, Aleksey;Ekidin, Aleksey;Nazarov, Evgeniy;Nikitenko, Vitaly;Pudovkin, Anton
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1723-1729
    • /
    • 2021
  • Energy and directional distribution of neutrons at the Beloyarsk NPP workplaces is a subject of this study. Measurements of H*(10) rate and neutron energy distribution were taken at 8 workplaces, which can be divided into three categories: work with spent or fresh nuclear fuel, work with radionuclide neutron sources, work at the rooms adjusted to reactors. The Hp(10) measurements were performed only at 6 out of 8 locations, due to the fact that long term placing of an effective neutron moderator in fresh nuclear fuel storage facility is forbidden. As a result of the research energy and direction distribution of the neutron fields at 8 locations of the Beloyarsk NPP workplaces was obtained. To estimate the accuracy of the H*(10) rate and Hp (10) measurements the reference values of dose equivalents were calculated using energy and directional distribution. To take into account the difference between the reference values and the measured results site-specific correction factors were calculated.

Purification of Hydrogenases from Purple Sulfur Bacterium Thiocapsa roseopersicina Using Various Applications of Chromatography (홍색 유황세근 Thiocapsa roseopersicina로 부터 생산되는 Hydrogenase의 각종 크로마토그래피에 의한 정제)

  • Choi, Eun-Hye;Oh, You-Kwan;Kim, Mi-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.2
    • /
    • pp.124-131
    • /
    • 2008
  • Crude cytoplasmic fraction of phototrophic purple sulfur bacterium, Thiocapsa roseopersicina NCIB 8347, were initially prepared and purified by sonication, ultracentrifugation, ammonium sulfate fractionation and heat-treatment and it has been previously reported. Using various applications of chromatography far the purification of membrane-bound and soluble hydrogenases from heat-treated enzyme fraction were studied at present report. When the heat-treated enzyme preparation was applied to the anion column chromatography using Q-sepharose, Fraction I and II, which were extracted with the KCl 0-0.5 M gradient, showed the specific evolution hydrogenase activity 3.86 and 2.27 U/mg-protein respectively. Specific hydrogenase activitys of Fraction I and II were further increased to 4.35 and 7.46 U/mg-protein for Fraction I and to 2.49 and 4.41 U/mg-protein fur Fraction II respectively, when hydrophobic interaction column, Phenyl superose, and anion exchange column, Mono-Q, were applied. Size exclusion chromatography using superdex 200 concentrated the hydrogenase Fraction I and II to 9.19 and 7.84 U/mg-protein respectively at the final step of purification.