• Title/Summary/Keyword: Specific conductivity

Search Result 520, Processing Time 0.029 seconds

Specific Heat and Thermal Conductivity Measurement of CNT/EEA Semiconducting Materials and XLPE Insulator (CNT/EEA 반도전층 재료와 XLPE 절연체의 열적 특성)

  • Yang, Jong-Seok;Lee, Kyoung-Yong;Shin, Dong-Hoon;Park, Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.514-519
    • /
    • 2006
  • To improve the mean-life and the reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconducting materials in 154[kV] underground power transmission cable. Specimens were made of sheet form with the seven of specimens for measurement. Specific heat (Cp) and thermal conductivity were measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]\;to\;90[^{\circ}C]$, and the heating rate was $1[^{\circ}C/min]$. And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C]\;and\;90[^{\circ}C]$. In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]\;to\;60[^{\circ}C]$, and the heating rate was $1[^{\circ}C/min]$. And the measurement temperatures of thermal conductivity were $25[^{\circ}C]\;and\;55[^{\circ}]C$. From these experimental results both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature. We could know that a small amount of CNT has a excellent thermal properties.

Analysis of Water Relations of Economic Oak Species by Hydraulic Architecture Method (Hydraulic architecture를 이용한 참나무속 주요 수종의 수분 특성 분석)

  • Kwon, Ki Won;Choi, Jeong Ho;Kim, Sun Ah
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.108-119
    • /
    • 1996
  • Several parameters of hydraulic architecture relating to hydraulic conductance in xylem vessels were investigated in the current-year shoots of six species of deciduous oak trees. The above parameters were also investigated in the sprouts of Quercus mongolica and Q. variabilis, as well as in the seedlings of Q. mongolica and Q. acutissima. The values of specific conductivity, leaf specific conductivity and Hagen-Poiseuille's relative hydraulic conductivity relating to vessel diameter of Q. dentata were the highest in all of the species studied. The above values of most of the species studied were higher in May-June than in September-October because of increasing the vessel embolism by cavitation and so on through the growing season. The estimated values of relative hydraulic conductivity of vessel by Hagen-Poiseuille's empirical equation and the real values of hydraulic conductivity presented positive relationships in most of the species studied. Huber value and leaf specific conductity using leaf area or leaf weight generally exhibited similar patterns each other even if having some exceptions. The hydraulic conductances of sprouting shoots were much better than those of normal growing shoots in Q. rnongolica and Q. variabilis. The specific conductivity and leaf specific conductivity were rapidly decreased by the vessel embolism through cavitating just after cutting the shoots in Q. mongolica and Q. acutissima seedlings. Diurnal changes of the conductivities in the seedlings of Q. mongolica and Q. acutissima presented the possibility of their self-controlling of conductance by active moisture absorption under mild water stress. Specific conductivity and leaf specific conductivity, and so on of Q. acutissima seedlings subjected to periodical moisture stress or not have decreased through the growing season, but the influences of moisture stress to the conductance were not proved definitely because of influencing similarly and simultaneously to the development of xylem and leaf having inverse relation in the influences. The values of conductivities were higher generally in middle or upper parts of stems than root collar in the seedlings.

  • PDF

Characteristics on the Non-Steady Heal Transfer of the STS 304 Hollow Cylinder (STS 304 중공 원통의 비정상 열전달 특성)

  • Lee, Sang-Chul;Kim, Young-Geun;Shim, Kyu-Jin;Bae, Kang-Youl;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1552-1557
    • /
    • 2004
  • This paper introduced about characteristics on the non-steady heat transfer of STS 304 hollow cylinder, In the non-steady state, the specific heat and conductivity are depended on the temperature variations, and these properties affect to the governing equation on heat conduction. But the most of numerical analysis on heat conduction is assumed to constant properties which is conductivity and specific heat. Assuming that conduction is assumed to constant properties which is conductivity and specific heat. Assuming that the properties are reacted sensitively, the numerical results can have the difference of between constant properties with non-constant properties. The main parameters are specific heat and conductivity. The temperature distributions of the STS 304 hollow cylinder became in steady state after 4 minutes in case of the constant properties. As the conductivity in varied with temperature, the temperature distributions became in steady state after 15 minutes. Therefore, a numerical analysis of the non steady state heat transfer will has to apply that conductivity varied with temperature.

  • PDF

Volume Resistivity, Specific Heat and Thermal Conductivity Measurement of Semiconducting Materials for 154[kV] (154[kV]용 반도전층 재료의 최적저항, 비열 및 열전도 측정)

  • Lee, Kvoung-Yong;Yang, Jong-Seok;Choi, Yong-Sung;Park, Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.477-482
    • /
    • 2005
  • We have investigated volume resistivity and thermal properties showed by changing the content of carbon black which is the component parts of semiconducting shield in underground power transmission cable. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the preheated oven of both 25$\pm$1[$^{\circ}C$] and 90$\pm$1[$^{\circ}C$]. And specific heat (Cp) and thermal conductivity were measured by Nano Flash Diffusivity and DSC (Differential Scanning Calorimetry). The measurement temperature ranges of specific heat using the BSC was from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity using Nano Flash Diffusivity were both 25[$^{\circ}C$] and 55[$^{\circ}C$]. Volume resistivity was high according to an increment of the content of carbon black from these experimental results. And specific heat was decreased, while thermal conductivity was increased by an increment of the content of carbon black. And both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

Analysis of Rainwater Samples in Cheju (제주도에서의 빗물 이온 농도 분석)

  • 심상규;강창희;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.98-104
    • /
    • 1994
  • Precipitation samples were collected at Kosan, Cheju Island over a period of 6 months An automatic rain sampler was manufactured domestically and installed at Kosan station. All samples were collected on a weekly basis. Samples were analyzed for S $O_4$$^{=}$, N $O_3$$^{[-10]}$ , C $l^{[-10]}$ , N $H_4$$^{+}$, N $a^{+}$, $K^{+}$, $Ca^{++}$, $Mg^{++}$, and pH and specific conductivity. The quality analysis of rain sample data were performed based on ion balance and specific conductivity. The pH of rain samples ranged between 4.6 to 6.6. Bicarbonate ion concentration were included in ion balance and specific conductivity calculations. The sum of cation concentrations were slightly greater than the sum of anion concentrations. Calculated specific conductivity was greater than measured specific conductivity. The most probable explanations for this discrepancy is "an anion too low or anion missing." Two criteria were used to identify outliners. They are 1) the difference between the sum of anion concentrations and cation concentration is more than 50 $\mu$eq./1 and 2) the difference between calculated and measured specific conductivity is more than 25%. Chemical analysis from several samples did not satisfy these quality control criteria. Volume weighted average concentrations were calculated. Dominant free acids in rain samples were N $a^{+}$, C $l^{[-10]}$ , S $O_4$$^{=}$, N $O_3$$^{[-10]}$ ions in order of abundance. Non-seasalt sulfate comprises 76% of total sulfate.sulfate.e.ate.e.

  • PDF

Specific Heat and Thermal Conductivity of XLPE Insulator and Semiconductive Materials for 154kV Power Cable (154kV 전력케이블용 XLPE 절연체와 반도전 재료의 비열 및 열전도)

  • Lee, Kyoung-Yong;Yang, Jong-Seok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.19-24
    • /
    • 2005
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconductive materials in 154kV underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added 30wt%, carbon black, and the other was made of sheet form by cutting XLPE insulator in 154kV power cable. Specific heat (Cp) and thermal conductivity were· measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from 20[$^{\circ}C$] to 90[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$}], 55[$^{\circ}C$] and 90[$^{\circ}C$]. In case of semiconductive materials, the measurement temperature ranges of specific heat were from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$] and 55[$^{\circ}C$]. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

  • PDF

Specific Heat and Thermal Conductivity Measurement of XLPE Insulator and Semiconducting Materials (XLPE 절연층과 반도전층 재료의 비열 및 열전도 측정)

  • Lee Kyoung-Yong;Yang Jong-Seok;Choi Yong-Sung;Park Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.6-10
    • /
    • 2006
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconducting materials in 154(kV) underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added $30[wt\%],$ carbon black, and the other was made of sheet form by cutting XLPE insulator in 154(kV) power cable. Specific heat (Cp) and thermal conductivity were measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]\;to\;90[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C]\;and\;90[^{\circ}C].$ In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]\;to\;60[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C].$ In addition we measured matrix of semiconducting materials to show formation and growth of carbon black in base resins through the SEM. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

Ecophysiological Interpretations on the Water Relations Parameters of Trees (XI) -The Comparison of Hydraulic Conductivity of Branch Junctions in Twenty-one Deciduous Broad-Leaved Species (수목(壽木)의 수분특성(水分特性)에 관한 생리(生理)·생태학적(生態學的) 해석(解析)(XI) - 낙엽(落葉) 활엽수(闊葉樹) 21종(種)의 분지부(分枝部)의 수분통도성(水分通道性) 비교(比較) -)

  • Han, Sang Sup;Kim, Sun Hee;Yi, Myong Jong
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.220-229
    • /
    • 1998
  • This study was performed to compare the characteristics of hydraulic conductivity such as relative conductivity(RC), leaf specific conductivity(LSC), Huber value(HV), specific conductivity(SC), and diameter of vessels(${\mu}m$) and number of vessels($No./mm^2$) in branch junctions of the twenty-one deciduous broad-leaved species. The hydraulic conductivities of branch junctions decreased with increasing junction angle between stem and branch, and with decreasing diameter of branch. The RC and LSC of branch junctions related to branching types(ㅏ, Y, ${\Psi}$ type) were much lower in ㅏ and ${\Psi}$ types than in Y type. The diameter and number of vessels remarkably reduced in branch junctions as compared with the stem and branch.

  • PDF

Sensitivity Study of Thermal Stresses in Mass Concrete Structures (매스 콘크리트 구조물의 수화열 및 응력 해석의 민감도 분석)

  • 차수원;김광수
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.160-167
    • /
    • 2001
  • Cracking in connote structures is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal analysis is used to prevent thermal mucking, but concrete properties are uncertain variable, and analysis results have uncertainty, too. In this study, sensitivity analysis is performed to investigate the effect of conductivity, specific heal and pouring temperature. The results show that lower conductivity and higher specific heat increase the maximum temperature and maximum tensile stress. The structure with internal restraint is mostly influenced by the change of conductivity and specific heat.

  • PDF

Ecophysiological Interpretations on the Water Relations Parameters of Trees(VIII) - The Hydraulic Architecture of Quercus mongolica (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(VIII) - 신갈나무의 수분통도성(水分通導性) 구조(構造) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.1
    • /
    • pp.120-129
    • /
    • 1996
  • This study was carried out to investigate the hydraulic architecture such as relative hydraulic conductivity, Leaf specific conductivity(LSC), Huber value, Specific conductivity of the stem, branch and Junctions of stem-to-branch in Quercus mongolica trees. The hydraulic architecture of various hydraulic conductivities of stem and branch was described. The results obtained were summarized as follows : 1. The range of relative hydraulic conductivity was $2.5526{\times}10^{-12}$ to $1.2260{\times}10^{-10}m^2$ in stems, $1.6279{\times}10^{-11}$ to $6.8378{\times}10^{-11}m^2$ in branches. The relative hydraulic conductivities increased with decreasing diameter of stem and branch. The relative hydraulic conductivity of one-year-old terminal shoots were two times greater than that of the lateral shoots. 2. LSC value was larger at the top than at the base in stem. LSC is much smaller in branches than in stem ; especially smallest at branching part. 3. Hydraulic conductivities of the branching part appeared the different values with the 4 type and 4 type. Relative hydraulic conductivity, LSC, Specific conductivity and mean vessel diameter in type branching part were larger in stem than in branch part, but not found in the branching part of Y type. 4. LSC and Specific conductivity of stem increased with decreasing diameter, but Huber value slowly increased with decreasing diameter ; especially highest at less than 1cm diameter. 5. LSC, Huber value, and mean diameter of vessels were larger at 1-year-old leader shoots than at lateral shoots. 6. The mean vessel diameter in various parts of a tree decreased with decreasing diameter of stem, but the number of vessels per unit area($mm^{-2}$) increased reversely. Mean vessel diameter in stem decreased sharply at earlywood and slowly at latewood with decreasing diameter of stem.

  • PDF