• Title/Summary/Keyword: Specific Noise

Search Result 692, Processing Time 0.037 seconds

Task-specific Noise Exposure Assessment of Firefighters

  • Kang, Taesun
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.569-576
    • /
    • 2019
  • Objectives: The main purpose of this study was to assess firefighters' daily personal noise exposure and explore noise levels related to specific tasks and their contributions to total noise exposure using 24-hour full-shift noise exposure measurements with task-based data. Methods: Noise exposure was assessed for eight firefighters (two rescuers, two drivers, and four suppressors) using time-activity diaries. We collected a total of 24 full-shift personal noise sample sets (three samples per a firefighter). The 24-hour shift-adjusted daily personal noise exposure level (Lep,d), eight weekly personal noise exposures (Leq,w), and 40 task-specific Leq values (Leq activity) were calculated via the ISO/NIOSH method. Results: The firefighter noise-sample datasets showed that most firefighters are exposed to noise levels above EU recommended levels at a low-action value. The highest noise exposure was for rescuers, followed by drivers and suppressors. Noise measurements with time-at-task information revealed that 82.3% of noise exposure occurred when checking equipment and responding to fire or emergency calls. Conclusions: The results indicate that firefighters are at risk of noise-induced hearing loss. Therefore, efforts at noise-control are necessary for their protection. This task-specific noise exposure assessment also shows that protective measures should be focused on certain tasks, such as checking and testing equipment.

Noise Assessment of Specific Vehicles Using Noise Map (소음지도를 이용한 특정차량의 소음평가)

  • Park, In-Sun;Jung, Woo-Hong;Park, Sang-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.750-753
    • /
    • 2006
  • Noise prediction is required as part of an environmental impact assessment. However, there has not been any comprehensive study or review en the major factors of specific vehicles affecting traffic noise so that there is difficulty when trying to figure out the source of noise. This study was to evaluate the noise effect of specific vehicles passing through a certain road by using noise map.

  • PDF

Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level (비소음 측정을 이용한 저소음 축류홴 설계)

  • 김창준;이동익
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

A Study on the Noise Assessment of Specific Vehicles at Metropolitan Landfill Area Using Noise Map (소음지도를 이용한 특정차량의 소음평가)

  • Park, In-Sun;Park, Sang-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1064-1068
    • /
    • 2007
  • Around metropolitan landfill area, specific vehicles such as garbage carrying trucks make noise problems and residents near landfill area organized to protest. However, it is difficult to distinguish the effect of noise of specific vehicles (ex: garbage trucks). In this study, noise map and CRTN were used to assess the noise from specific vehicles. Noise levels, which were predicted by using measured parameters such as traffic flow, traffic speed, composition of traffic for 1 year, were compared with measured results of noise level.

A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings (공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구)

  • Ham, Jin-Sik
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구(1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.548-553
    • /
    • 1998
  • The specific noise level of 18 rotary compressor mufflers were measured and these data were analyzed by the Taguchi robust design method and the neural network. The optimal design value obtained by the neural network generally showed good agreement with that by the Taguchi method. The effects of eight important design variables on the specific noise level were discussed.

  • PDF

Specific Reaction to Road-traffic Noise (도로교통소음에 대한 주민들의 반응)

  • Koh, Dai-Ha;Youm, Jung-Ho;Kwon, Keun-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.283-292
    • /
    • 2004
  • Valid evaluation of community reaction to road-traffic noise exposure is important for the policy making and quality of life. The purpose of this study is to evaluate the relationship between community reaction and nighttime road-traffic noise. The study measured nighttime roadside noise caused by high traffic which is greater than LAeq(22:00-07:00) 65dB(A) and lower than 65dB(A) at Chonju city, from March to April, 2003. Three hundred sixty seven subjects, aged from 20 to 65, were selected from those who are residing close to the major roads. They were asked to answer the questions regarding noise source, stress(PWI-SF), annoyance, disturbance of specific activity, disturbance of sleep, somatic symptom, and four suggested confounding factors. The relationship between annoyance, somatic symptom and noise exposure was not significant. Adjusted odds ratio(95% C.I.) for disturbance of communication  and disturbance of attention and rest  were 1.59(1.03-2.71), 1.64(1.06-2.81), respectively. On the other hand sleep disturbance  was indicated as 1.34(0.77-2.32). The results suggested that federal policy-making about road-traffic noise should consider community reaction evaluated by various perspective including annoyance, disturbance of specific activity, disturbance of sleep, and confounding factors.

Prediction of Specific Noise Based on Internal Flow of Forward Curved Fan

  • Sasaki, Soichi;Hayashi, Hidechito;Hatakeyama, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.1
    • /
    • pp.80-91
    • /
    • 2009
  • In this study, a prediction theory for specific noise that is the overall characteristic of the fan has been proposed. This theory is based on total pressure prediction and broadband noise prediction. The specific noises of two forward curved fans with different number of blades were predicted. The flow around the impeller having 120 blades (MF120) was more biased at a certain positions than the impeller with 40 blades (MF40). An effective domain of the energy conversion of MF40 has extended overall than MF120. The total pressure was affected by the slip factor and pressure loss caused by the vortex flow. The suppression of a major pressure drop by the vortex flow and expansion of the effective domain for energy conversion contributed to an increase in the total pressure of MF40 at the design point. The position of maximum relative velocity was different for each fan. The relative velocity of MF120 was less than that of MF40 due to the deviation angle. The specific noise of MF120 was 2.7 dB less than that of MF40 due to the difference in internal flow. It has been quantitatively estimated that the deceleration in the relative velocity contributed to the improvement in the overall performance.

Multiple Noise Analysis of the Inside Equipments in Shelter System (쉘터시스템 내부 장비의 복합 소음 분석)

  • Kim, Sang-Hyun;Lee, Byung-Ho;Lee, Sock-Kyu;Lee, Jeung;Kang, Dong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.255-265
    • /
    • 2015
  • Shelter system is applying to weapon systems as usage of performing specific mission with arranging several electronic equipments and operators. Recently the electronic equipments is changing from development products to COTS(commecial off-the-shelf) for demonstrating high performance at low cost. As internal operators of shelter system conduct several missions for specific or long time in this present situation, one of the most important element considering the best combat power is internal noise level. Therefore, I desire to analyze the features and foresee multiple noise level with test for conforming whether requirements of design is met or not in this research paper.

Multiple noise analysis of the inside equipments in shelter system (쉘터시스템 내부 장비의 복합 소음 분석)

  • Kim, Sang-Hyun;Lee, Byung-Ho;Lee, Jeung;Kang, Dong-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.60-65
    • /
    • 2014
  • Shelter system is applying to weapon systems as usage of performing specific mission with arranging several electronic equipments and operators. Recently the electronic equipments is changing from development products to COTS(Commecial on-the-shelf) for demonstrating high performance at low cost. As internal operators of shelter system conduct several missions for specific or long time in this the present situation, One of the most important element considering the best combat power is internal noise level. Therefore, I desire to analyze the features and foresee muliple noise level with test for conforming whether requirements of design is met or not in this research paper.

  • PDF